00193794-11_VD_SSW 505.05_de en - 第31页

Software Version Description, Station Software 505.05 07/2008 Edition 932 -1 -1 0 0 0 0 0 0 4200 3 933 -1 -1 0 0 0 0 0 0 5500 3 934 -1 -1 0 0 0 0 0 0 5000 3 935 -1 -1 0 0 0 0 0 0 6000 3 936 -1 -1 0 0 0 0 0 0 5500 3 PipZS…

100%1 / 150
Software Version Description, Station Software 505.05 07/2008 Edition
5.2 Improved error detection for "missing nozzles"
A monitoring function is implemented to detect immediately missing nozzles on the placement head.
Then a fatal machine error is displayed.
In this case check the PCB and the segment and reset the nozzle. The placement process can be
continued.
Restrictions
The function depends on the nozzle type and is not supported for all nozzle types, see the table
below.
PipTyp
VakSchwellwert
VakGrenzwert
VakOffenAbh
VakCheckMode
ZhoehenMin
ZhoehenMax
ZcheckMode
MinVakDeltaOffenZu
PipZSchwellwert
PipCheckMode
901 2000 30 55 1 200 1000 1 55 4000 3
902 -1 -1 0 0 0 0 0 0 4000 3
904 4000 40 100 1 500 1000 1 120 5000 3
906 -1 -1 0 0 0 0 0 0 4000 3
911 2000 30 55 1 200 1000 1 55 4000 3
913 -1 -1 0 0 0 0 0 0 5500 3
914 4000 40 100 1 500 1000 1 120 5000 3
915 -1 -1 0 0 0 0 0 0 6000 3
923 -1 -1 0 0 0 0 0 0 5000 3
924 -1 -1 0 0 0 0 0 0 5000 3
925 2000 30 55 1 200 1000 1 50 4000 3
30 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
932 -1 -1 0 0 0 0 0 0 4200 3
933 -1 -1 0 0 0 0 0 0 5500 3
934 -1 -1 0 0 0 0 0 0 5000 3
935 -1 -1 0 0 0 0 0 0 6000 3
936 -1 -1 0 0 0 0 0 0 5500 3
PipZSchwellwert: Threshold value as of which the nozzle is detected as missing
(Z_actual – Z_target >= Z_Threshold)
PipCheckMode:
0:off
1: on (warning in case of error)
2: Machine immediately on (FE, fatal error);
3 Machine stops after head cyclus mit FE
4: Fatal error (head reference run)
5.3 Connection of line computers and monitoring of the MaDaMas
data
As of this station software version it is possible to connect line computers as of the line computer
version 503.06 (Item no. 00193520-xx) for the following machines:
- HS-50, HS-60
- S-25, S-27
There, any features of the station software 503 are supported.
Restrictions
The connection of the line computers is not possible for the machines HF and HF3.
31 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
5.4 New S feeder: Shutterless S feeder 3x8mm SL
The station software supports a new S feeder type, called "Shutterless S Feeder, 3x8mm SL"
The feeder has two pickup positions:
- one for components with 0,8mm width
- one for components with > 0,8 mm width
The functionality and properties of the shutterless s feeder is the same as for standard S feeder.
Restrictions
The shutterless S feeder requires SIPLACE Pro 5.0.
5.5 Support of OIS/SIS
Two OIS events were added.
Thus, the station software notifies OIS, whether or not the machine is in stand alone mode.
5.6 Fine calibration enabled
As of this version the fine calibration is unrestricted enabled .
5.7 Synchronization of data provision
Integration of the "Mobilink" patch
In order to avoid data provision problems on a job change, the Setup Center only sends the data to
the station when data preparation has been completed and the new job has been specified by
SIPLACE Pro. The Setup Center and the station are synchronized when a job is specified.
5.8 Revision of the dual conveyor
Up to now, the PCB barcode was restricted to 2 x 12 characters on the synchronous dual conveyor.
This restriction has been lifted. 2 x 40 characters are permitted.
32 of 150