Software Version Description, Station Software 505.05 07/2008 Edition Error number Description D1-40782113 Due to a faulty setting for the column widt h in the track error dialog, the columns were truncated in some langu…

Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D1-34886208 Pseudo track empty error. A track empty error message was displayed but the
machine picked up the component from the track concerned. The error message is
now displayed as an common error.
D1-36083327 The main error display was not activated at machine error 3574.
D1-36759801 After registration of a changeover table on an HS50 machine, trays with dual
packaging units were not unlocked, as the infrastructure was overloaded due to a high
amount of message. The architecture has been improved.
D1-36975233 After a program change on an HF/3 machine, the first component inspected by the
coplan laser was always rejected and no error message was displayed on the station
computer. The measuring command was handed over too late.
D1-38290611 After installation of the station software 505.04 SP1 on an HS60 machine, the
Component level indicator showed "0" as original quantity of all components.
D1-39609001 On an HF machine a track empty error occured, as the tape component pocket was
empty. After the track was set to full the transport moved towards the component with
full power. The machine hung up with the error message 19080 "Crash danger!
Segment cannot be transported to a higher position". Teaching is now being
deactivated when vacuum check is off.
D1-40108702 Due to an incorrect message for the DIP switch, it was not possible to download the
firmware for station software 505.04 SP2. The message has been corrected.
D1-40156649 On an S27 HM machine with multicolor cameras the hotfix_2 to 505.04 SP2 did not
work correct. The potential correction of the component pickup position regularly
caused a permanent camera flashlight and it was impossible to quit with the "Esc"
button. The error has been corrected.
D1-40216904 On an HF/3 machine the component level of the packaging unit was lost after
rebooting the station. The process has been optimized.
D1-40637259 Due to a translation error, it seemed to be possible to choose between a 3x8 and a
2x8mm feeder in the fine calibration in som languages. The GUI text has been
corrected for the languages concerned.
D1-40706513 On an HF/3 machine an error message was displayed, that the distances of the PCB
fiducials were beyond the tolerance. The tolerance value was to low in the data base
for the multicolor camera. The tolerance value has been adjusted in the data base.
D1-40767931 After an upgrade from station software 505.03 SP1 to 505.04 SP2 on an HF/3 machine
an internal system error occurred. The error has been corrected.
73 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D1-40782113 Due to a faulty setting for the column width in the track error dialog, the columns were
truncated in some languages. The column width has been corrected for the languages
concerned.
D1-40956607 Problems occurred with the tray stack loader in combination with pickup or Vision
errors on an HF/3 machine. The machine hung up without displaying any error
message because the program branched to the false function and ran in an infinite
loop. The error has been corrected in the software.
D10610-3307 After a program change on the HS50 stations, the tracks had to be rescanned after the
tables were scanned (firm setup) to start production. The interface between station and
Setup Center has been adapted.
D11578-4207 On an HS60 machine the mounted star was damaged when the C&P head was
calibrated due to an sequence error in the software. The error has been corrected.
D11901-1223 On an HF/3 machine the TwinHead tried to change the nozzle, although the
component was still on the nozzle. The error has been corrected.
D11909-2211 On an S25 machine the fine calibration calculated the machine accuracy by 60µm
instead of 90 µm. By processing the registry scripts, the machine dependent settings
were set before the default settings and therefore were overwritten by these. The
sequence order of registry script processing has been changed.
D11962-2801 A machine hung up with an error message as the coplanarity module lost the
connection to the machine. The machine had to be rebooted. The error occurred, while
the coplanarity module answered the machine controller incorrectly.
D12045-1029 On an HS60 machine the component level indicators for the reels differed in Setup
Center and at the station because Setup Center did not evaluate the component level
in the station interface. The error has been corrected in Setup Center.
D12087-4706 After upgrading to station software 505.04 SP2 the HS50 machine could not simulate
production, while a counter was incremented too often. The counter will now be
incremented correct.
D12301-709 On an HF/3 machine the z axis of the Twin segment impacted with the IC camera. No
error message was displayed and the z axis was broken. The error has been
corrected.
D12541-5107 Z axis freezed on the calibration tool during calibrating offset I whenever SITEST
begun after producing, because a pointer was not checked. The process has been
corrected.
74 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D12816-1417 After upgrading to station software 505.04 SP2 problems occurred, because no
tolerance values were entered for the multicolor camera in the database. The
tolerance values have been entered.
D12975-514 On an HF/3 machine the TwinHead glass broke after an upgrade to station software
505.04 SP2 due to problems with the z and rotary axes. The error has been corrected.