00193794-11_VD_SSW 505.05_de en - 第75页

Software Version Description, Station Software 505.05 07/2008 Edition Error number Description D12816-1417 After upgrading to station software 505.04 SP2 problems occurred, because no tolerance values were entered for th…

100%1 / 150
Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D1-40782113 Due to a faulty setting for the column width in the track error dialog, the columns were
truncated in some languages. The column width has been corrected for the languages
concerned.
D1-40956607 Problems occurred with the tray stack loader in combination with pickup or Vision
errors on an HF/3 machine. The machine hung up without displaying any error
message because the program branched to the false function and ran in an infinite
loop. The error has been corrected in the software.
D10610-3307 After a program change on the HS50 stations, the tracks had to be rescanned after the
tables were scanned (firm setup) to start production. The interface between station and
Setup Center has been adapted.
D11578-4207 On an HS60 machine the mounted star was damaged when the C&P head was
calibrated due to an sequence error in the software. The error has been corrected.
D11901-1223 On an HF/3 machine the TwinHead tried to change the nozzle, although the
component was still on the nozzle. The error has been corrected.
D11909-2211 On an S25 machine the fine calibration calculated the machine accuracy by 60µm
instead of 90 µm. By processing the registry scripts, the machine dependent settings
were set before the default settings and therefore were overwritten by these. The
sequence order of registry script processing has been changed.
D11962-2801 A machine hung up with an error message as the coplanarity module lost the
connection to the machine. The machine had to be rebooted. The error occurred, while
the coplanarity module answered the machine controller incorrectly.
D12045-1029 On an HS60 machine the component level indicators for the reels differed in Setup
Center and at the station because Setup Center did not evaluate the component level
in the station interface. The error has been corrected in Setup Center.
D12087-4706 After upgrading to station software 505.04 SP2 the HS50 machine could not simulate
production, while a counter was incremented too often. The counter will now be
incremented correct.
D12301-709 On an HF/3 machine the z axis of the Twin segment impacted with the IC camera. No
error message was displayed and the z axis was broken. The error has been
corrected.
D12541-5107 Z axis freezed on the calibration tool during calibrating offset I whenever SITEST
begun after producing, because a pointer was not checked. The process has been
corrected.
74 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
Error number Description
D12816-1417 After upgrading to station software 505.04 SP2 problems occurred, because no
tolerance values were entered for the multicolor camera in the database. The
tolerance values have been entered.
D12975-514 On an HF/3 machine the TwinHead glass broke after an upgrade to station software
505.04 SP2 due to problems with the z and rotary axes. The error has been corrected.
75 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
7 Restrictions
- Revision of the Forced Setup Verification:
The forced setup verification requires SIPLACE Pro as of Version 5.0 and SIPLACE Setup
Center as of Version 3.0.
- Shutterless feeder – Teaching pickup position:
On an S-27 HM machine it may be necessary to increase or decrease the y axis traversing
range.
The functionality is not supported on S25 HM machines.
- Whispering of fiducials:
See the "
Whispering of ink spots" section.
The functionality requires SIPLACE Pro as of Version 5.0.
- Repair placement of components still attached to the nozzle
Placement levels are not supported.
Repair placement may be performed several times on positions without considering that thus
the flux media thickness reduces.
Before a setup change, deactivated segments must be activated or the nozzles have to be
removed from the deactivated segments. Otherwise the system would probably try to pick up a
new nozzle, although a nozzle is still available.
No automatic change of deactivated nozzles will be performed during replacement operation.
If the PCB cannot be completely placed due to the deactivation of a segment, the machine stops
with a track empty error. In this case, no automatic nozzle change is possible.
- Deactivating tape cutter
After a reconfiguration (component table / MTC) possibly all locations might not be available in
the Software Options before the first reference run.
- Improved error detection for "missing nozzles:
The function depends on the nozzle type and is not supported for all nozzle types.
- Connection of line computers:
The connection of the line computers is not possible for the machines HF and HF3.
- Shutterless S feeder 3x8mm SL:
The shutterless S feeder requires SIPLACE Pro 5.0.
76 of 150