00190802-02 - 第16页

1 Hardware / Software Installati o n User’s Manu al Line Computer UNIX 1.1 Introduction Software Version 402.xx Edit ion 06/9 6 1 - 2

100%1 / 577
User’s Manual Line Computer UNIX 1 Hardware / Software Installation
Software Version 402.xx Edition 06/96 1.1 Introduction
1 - 1
1 Hardware / Software Installation
1.1 Introduction
This chapter describes the design of the two computer and monitor types as well as other components used
for the operation of the line computer software.
It is intended to help the user to properly connect the hardware components so as to ensure their correct
functioning, to perform correctly any adjustments that may be required and so to prevent any damage to the
hardware.
Moreover, this chapter explains how to install the LC software.
NOTE
The installation of the operating system SCO UNIX 3.0 is performed at Siemens, AUT 5.
1 Hardware / Software Installation User’s Manual Line Computer UNIX
1.1 Introduction Software Version 402.xx Edition 06/96
1 - 2
User’s Manual Line Computer UNIX 1 Hardware / Software Installation
Software Version 402.xx Edition 06/96 1.2 Hardware Installation
1 - 3
1.2 Hardware Installation
1.2.1 Hardware Components
NOTE
The following chart shows the two possible hardware configurations that can be used for your work with the
line computer program. The first column contains the data of the hardware components used for already
existing line computer systems, the second column contains the data of the hardware components used for
new systems.
Hardware Components Existing Configuration New Configuration
Computer type SIPLACE 486/66 DX2 SIEMENS NIXDORF PCD-5H
Pentium 90 MHz
Cabinet Big Tower Desktop
Hard disk approx. 550 MB approx. 1 GByte
Main memory (RAM) 32 MB 32 MB
Floppy disk drive 1.2 MB (5
1
/
4
")
1,44 MB (3
1
/
2
")
1.44 MB (3
1
/
2
")
Streamer type drive 250 MB 525 MB
Ports 2 serial, 1 parallel 2 serial, 1 parallel
Keyboard USA SIEMENS US English
Mouse Bus mouse Keyboard mouse
Network adapter LAN card LAN card
Monitor type SIPLACE 17" FLEXSCAN,
MPR II
SIEMENS NIXDORF MCM 1702
or MCM 1754 (ND)
17" MULTISCAN, MPR II
Line frequency 20 kHz - 50 kHz 30 kHz - 82 kHz
UPS type
(U
ninterruptible Power
S
upply)
SIPLACE 660 VA SIPLACE 660 VA
Capacity 660 VA/400 W 660 VA/400 W
Mains input 100-120 VAC/220-240 VAC,
50/60 MHz
100-120 VAC/220-240 VAC,
50/60 MHz
Back-up time approx. 10 minutes
(load-dependent)
approx. 10 minutes
(load-dependent)