00190802-02 - 第435页

User’s Manual Line Computer UNIX 14 Control / Control Modules Software Version 402.xx Edition 06/96 14.4 Station Control lers 14 - 33 14.4 Station Controller s Job Contr ol send s jobs to the stati on contro llers of the…

100%1 / 577
14 Control / Control Modules User’s Manual Line Computer UNIX
14.3 Line Control Software Version 402.xx Edition 06/96
14 - 32
-
Entering Edited Data
Refer to the description for the line (page 14 - 29).
-
Start
/
Stop
of Subline
The Start or Stop button is used to start or stop, respectively, the current subline.
Click on appropriate button
Start
or
Stop
.
-
Blocking
/
Unblocking
of input conveyor
The Block or Unblock button is used to block or unblock, respectively, the input conveyor of the cur-
rent subline.
Click on
Block
or
Unblock
button.
User’s Manual Line Computer UNIX 14 Control / Control Modules
Software Version 402.xx Edition 06/96 14.4 Station Controllers
14 - 33
14.4 Station Controllers
Job Control sends jobs to the station controllers of the required stations.
Each physical station has been assigned a station controller supplying the station with machine data, setup
data and placement data and controlling the processes performed at the stations. The data are transmitted to
the stations by the Data Manager via an IEC bus.
The station controller's user interface provides the operator with the following information:
-
current station data
-
job allocation
-
logged-on PCBs
14.4.1 Tasks
The station controllers are designed to synchronize the user entries at the Job Control with the processes
performed on the stations so that, at the appropriate instant
-
setup changeover is initiated
-
and the placement data are loaded.
14.4.2 Features
Jobs (batches) are allocated to the station controller by a job control.
-
Several jobs can be allocated to a station controller at once.
Active are: without barcode ---> the first lot
with barcode ---> n-lots of the same setup
-
Each station controller is allocated to one physical station.
-
The station controller allows the handling of "high-priority" jobs.
14 Control / Control Modules User’s Manual Line Computer UNIX
14.4 Station Controllers Software Version 402.xx Edition 06/96
14 - 34
14.4.3 Opening the "Station Controller" User Interface
Every placement station represented in the current line configuration display is provided with an icon labelled
with the "
i
" symbol (see "Desktop" user interface in chapter 3, Fig. 3.1.2). Clicking on this symbol causes the
user interface of the respective station controller to be opened.
Click on the area of the desired station containing the "
i
" symbol.
The user interface (main window) of the station controller is opened (see Fig. 14.4.1).
The following information on the selected station is provided in this window:
-
names of Line and Station
-
settings of Barcode and UFO strategies
-
lot name, PCB type, number of pieces (PCBs)
-
PCB identification number
-
setup of station
-
current conveyor width setting
-
listings of lots or PCBs (upon request)
NOTE
When the main display window and the windows containing the requested listings are open, all