00190802-02 - 第506页
17.2 Description of Components and PCBs User’s Manual SIPLACE Line Com puter UNIX 17.2.1 PCB 1: single circuit Software V ersion 402.xx Edition 06/ 96 17 - 6 Entering th e dime ns- ions of th e PCB Definin g fiducia ls c…

User’s Manual SIPLACE Line Computer UNIX 17.2 Description of Components and PCBs
Software Version 402.xx Edition 06/96 17.2.1 PCB 1: single circuit
17 - 5
17.2.1.1 Package Form Description
The package forms used are contained in the standard GF-library, the description is dispensed with.
17.2.1.2 Component Description
To open the Component Editor for a component, proceed as follows:
1. On the desktop click on the icon of the Component Editor .
The file selection window is opened.
2. Click on the
Selection
editing field.
3. Enter the name of the component, here:
Comp1.be
, click on the
OK
button.
The Component Editor is opened.
To enter the component data, proceed as follows:
4. Click on the
Comment
editing field.
5. Enter a comment uniquely describing the component, here:
SOT23
.
6. Click on the
Package form
editing field.
7. Enter the package form number, here:
400
.
8. Activate the appropriate button in the
Processing
selection area, here:
Placing
and
Glueing
.
9. Activate the appropriate button in the CRDL selection area, here:
No check
.
10. On the
FILE
menu click on the
Save
option.
The component data are now saved.
11. On the
FILE
menu click on the
Quit
option.
The Component Editor is closed.
12. Perform the component description for the other components, here:
Comp2.be
and
Comp3.be
.
17.2.1.3 Adhesive Pattern (DM) Description
An adhesive pattern has already been defined in the standard GF-Bibliothek for the package forms defined.
17.2.1.4 PCB Description
To open the PCB Editor for a PCB, proceed as follows:
13. On the desktop click on the icon of the PCB Editor .
The file selection window is opened.
14. Click on the
Selection
editing field.
15. Enter the name of the PCB, here:
Example_1.la
and click on the
OK
button.
A dialog box is opened.
16. Click on the
TYPE
editing field.
17. Enter a type designation, here:
SMD a
nd click on the
OK
button.
The PCB Editor is opened. The PCB is represented as a rectangle.
To specify the position of the PCB in the machine, proceed as follows:
18. Click on the Coordinate System icon.
19. Click on the PCB (rectangle).
A dialog box containing the display of four coordinate systems is opened.
20. Click on a coordinate system, here:
0°
.
21. Click on the
OK
button.
The dialog box is closed.

17.2 Description of Components and PCBs User’s Manual SIPLACE Line Computer UNIX
17.2.1 PCB 1: single circuit Software Version 402.xx Edition 06/96
17 - 6
Entering the dimens-
ions of the PCB
Defining fiducials
continued from page 17-4
PCB Description
Cluster Editor
Fiducial Editor
continued on page 17-8

User’s Manual SIPLACE Line Computer UNIX 17.2 Description of Components and PCBs
Software Version 402.xx Edition 06/96 17.2.1 PCB 1: single circuit
17 - 7
To enter the dimensions of the PCB, proceed as follows:
22. Click on the Menu icon.
23. Click on the PCB (rectangle).
24. On the
SERVICES
menu click on the
Cluster Editor...
option.
The Cluster Editor is opened.
25. Enter the dimensions of the PCB. See Fig. 17.2.1 on page 17-3 and Fig. 17.2.2 .
Fig. 17.2.2 Cluster Editor for PCB 1
To define the fiducials, proceed as follows:
26. In the Cluster Editor click on the
Edit fiducials
button.
The Fiducial Editor is opened.
27. Activate the
Insert
button.
28. Click on the
Fiducial set name
editing field.
29. Enter the name for the new fiducial set, here:
Set_1
.
30. Click on the
Accept fiducial set
button.
Fiducial set Set_1
appears on the fiducial list.
31. Click on fiducial set Set_1
on the fiducial list.
32. Click on the
Fiducial
editing field.
33. Enter the fiducial number, here:
48
.
34. Click on the editing fields for the coordinates, enter coordinates
(do not confirm by pressing the Enter key!), here: see chart:
35. Click on the
Accept fiducial data
button.
The fiducial data are transferred to the list of the fiducials of the fiducial set.
36. Define the other fiducials accordingly, here:
fiducials
48
and
48
.
37. Activate the
PCB position recognition
button.
38. Click on fiducial set Set_1 on the fiducial list.
The fiducial set
Set_1
is marked by a preceeding
L
for PCB position recognition.
Fiducial number X Y
48 -5 30
48 81 -10
48 81 30
Activate the PCB position
recognition