DECAN_S2_Operation(ENG_Ver4.1).pdf - 第57页

It ems t o b e inspe ct e d du r ing p r oduction Chap ter 4 Advanced Chip Shooter DE CAN S2 O pe rat ion H an db ook 4-1 4 This chapter describes the methods for temporary stop of the machine(Continue / Start mode), eme…

100%1 / 92
Items to be inspected during production
Chapter 4
Advanced Chip Shooter
DECAN S2 Operation Handbook
4-13
This chapter describes the methods for temporary stop of the
machine(Continue / Start mode), emergency stop (by manual/ by
system) and the restarting the production after emergency stop when
checking errors or other items and taking measures during production.
Emergency Stop > The emergency stop by operator
Emergency Stop
1. The emergency stop by operator
1. The emergency stop by operator
Step 1.
Press the 'EMG' switch on operation panel or the 'FREE' button
on the teaching box
Warning
Be sure to remove the cause of emergency stop before restarting
2. Releasing 'Emergency Stop' mode
Step 1.
Release the pressed 'EMG' switch by turning clockwise
Step 2.
Press the 'STOP' button
Emergency Stop
Items to be inspected during production
Chapter 4
Advanced Chip Shooter
DECAN S2 Operation Handbook
4-14
This chapter describes the methods for temporary stop of the
machine(Continue / Start mode), emergency stop (by manual/ by
system) and the restarting the production after emergency stop when
checking errors or other items and taking measures during production.
Emergency Stop > The emergency stop by operator
Emergency Stop
Items to be inspected during production
Step 3.
Press the 'RESET' button
Step 4.
Find the cause of the emergency stop, and remove it
Step 5.
Press the 'READY' button
Caution
In case that the machine stops in an emergency state and then
the production is restarted, the operator must check if there is any
component on the PCB due to emergency stop before pressing the
'READY' button. If he/she finds any, it must be removed.
Items to be inspected during production
Chapter 4
Advanced Chip Shooter
DECAN S2 Operation Handbook
4-15
This chapter describes the methods for temporary stop of the
machine(Continue / Start mode), emergency stop (by manual/ by
system) and the restarting the production after emergency stop when
checking errors or other items and taking measures during production.
Emergency Stop > System emergency stop: How to take measures against the emergency stop due to the judgment of the system itself
Emergency Stop
2. System emergency stop: How to take measures
against the emergency stop due to the judgment of
the system itself
Step 1.
Press the 'STOP' button to turn off the buzzer
Step 2.
Check the error information displayed on the monitor of the
machine.