SIPLACE S-23 HM - 第157页

User Manual SIPLAC E S-23 HM 5 Single Functions Software Version SR.406.xx 02/00 US Edition 5.2 Single functions, Gantry 157 Reject circ uit - Forced air on/off 5 When t his funct ion is activa ted, the f orced ai r at t…

100%1 / 454
5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.406.xx 02/00 US Edition
156
5.2.1.1 Functions
In the "Revolver head functions" screen, the functions described below are available to help you
test the revolver head. 5
Vacuum test in the pick-up position
Vacuum test in the reject position
Vacuum test in the holding circuit
Revolver head functions
The functions are triggered by clicking the appropriate button. 5
Pick-up circuit - Forced air on/off 5
When this function is activated, the forced air to the nozzle in the pick-up position is either
switched on or off.
Å In the "Pick-up circuit" area, click the Forced air on/off button.
This switches the forced air on or off.
Pick-up circuit - Vacuum on/off 5
When this function is activated, the vacuum at the nozzle in the pick-up position is either
switched on or off.
Å In the "Pick-up circuit" area, click the Vacuum on/off button.
This switches the vacuum on or off.
Pick-up circuit - Measure forced air 5
When this function is activated, forced air at the pick-up position is measured.
Å Switch on the forced air (using the "Forced air on/off" function in the "Pick-up circuit" area).
Å Click the Measure forced air button in the "Pick-up circuit" area.
The forced air is measured and the result displayed in [mbar] above the button.
NOTE
The value displayed after the measurement is taken does not correspond to the actual values at
the nozzle.
When calibrating the machine, you must use a manometer to establish the values (see Adjustment
instructions or the Service Manual). 5
Pick-up circuit - Measure vacuum 5
When this function is activated, vacuum at the pick-up position is measured.
Å Switch on the vacuum (using the "Vacuum on/off" function in the "Pick-up circuit" area).
Å Click the Measure Vacuum button in the "Pick-up circuit" area.
The vacuum is measured and the result displayed in [mbar] above the button.
User Manual SIPLACE S-23 HM 5 Single Functions
Software Version SR.406.xx 02/00 US Edition 5.2 Single functions, Gantry
157
Reject circuit - Forced air on/off 5
When this function is activated, the forced air at the nozzle in the reject position is switched on or
off.
Å Click the Forced air on/off button in the "Reject circuit" area.
The forced air is switched on or off.
Reject circuit - Vacuum on/off 5
When this function is activated, the vacuum to the nozzle in the reject position is switched on or
off.
Å Click the Vacuum on/off button in the "Reject circuit" area.
The vacuum is switched on or off.
Head reference run 5
This function is used to start a head reference run of all the head axes, or in other words, all head
axes travel to their origin. The gantry axes travel over the reject container and discard compo-
nents in a defined manner.
Å Click the Head reference run button.
The head axes execute a head reference run.
Holding circuit - Measure vacuum 5
When this function is activated, the vacuum at the nozzle in the holding circuit is measured.
Å Click the Measure vacuum button in the "Holding circuit" area.
The vacuum is measured and the result displayed in [mbar] above the button.
Star in position 1 5
This function is used to bring the revolver head into a defined starting position.
Å Click the Star in position 1 button.
The revolver head is moved round so that segment 1 is in the pick up and placement position
(lowest position). In addition the revolver head and the z-axis perform a reference run.
RV head indexing 5
This function is used to move the revolver head. Each time you click the button the revolver head
is moved round by one segment.
Å Click the RV head indexing button.
The revolver head is moved by one segment.
The current positions of the segments is displayed in the graphic.
5 Single Functions User Manual SIPLACE S-23 HM
5.2 Single functions, Gantry Software Version SR.406.xx 02/00 US Edition
158
Actuate DP-axis 5
When this function is activated, the nozzle in the dp1 axis is rotated by 90
0
.
Å Click the Actuate DP-axis button.
The nozzle in the dp1 axis is rotated by 90
0
once.
5
5.2.2 "Gantry functions" screen
Å In the current screen for the single functions for Gantry x, click the symbol .
The user interface is switched to the "Gantry functions" screen (see Fig. 5.2 - 2).
5