SIPLACE S-23 HM - 第172页
5 Single Functions User Manual SIPLACE S -23 HM 5.3 Single functions, Transport Software Version SR.406.xx 02/00 US Edition 172 5.3 Single functions , T ransport NOTE The travel function s of th e x or y ax is can only b…
User Manual SIPLACE S-23 HM 5 Single Functions
Software Version SR.406.xx 02/00 US Edition 5.2 Single functions, Gantry
171
Confirm magaz. 5
This function is used to confirm that an individual magazine has been filled with a new nozzle
type.
When changing the set-up of a machine it may be necessary to change the type of nozzle in
some of the magazines. To do this, the current nozzle configuration (Actual) and the nozzle con-
figuration for the new set-up (Preset) is shown in the table for each of magazine. When you
change the nozzle type from the "Actual" to "Preset" type, you must confirm this for each maga-
zine separately.
Å Click the entry in the table which corresponds to the magazine for which you must change the
nozzle type. The line is now highlighted in light blue.
Å Click the Lock. op./close button.
Å Replace all the nozzles in this magazine with the nozzle type shown in the "Preset" column.
Å Click the Lock. op./close button again.
Å Click the Confirm magaz. button.
The change of is now confirmed. In the table, the arrow ( <== ) is no longer displayed next to
the entry for this magazine.
5
5

5 Single Functions User Manual SIPLACE S-23 HM
5.3 Single functions, Transport Software Version SR.406.xx 02/00 US Edition
172
5.3 Single functions, Transport
NOTE
The travel functions of the x or y axis can only be carried out when the machine cover is closed.
To execute this function, press the start button.
As a rule, the gantries only travel slowly. The revolver head is set to travel slowly. 5
Å On the tool bar in the main view, click the symbol which represents the transport you want to
test the functions of (or select the corresponding menu item from the "View" menu, e.g. "Trans-
port 1" for Transport 1).
NOTE
When dual transport is installed and available in the machine configuration, the single func-
tions can be called for either the right-hand transport (Transport 1) or the left-hand transport
(Transport 2). The functions are identical for both right and left. The symbols used to call the
single functions are marked with the number which corresponds to the transport side.
Example for Transport 1 (= right-hand transport or single transport). 5
The user interface is switched to the "Transport functions" screen of the selected transport (see
Fig. 5.3 - 1). 5
5

User Manual SIPLACE S-23 HM 5 Single Functions
Software Version SR.406.xx 02/00 US Edition 5.3 Single functions, Transport
173
5.3.1 "Transport functions" screen
The transport functions are used for checking and adjusting the functional modules of the board
conveying systems. 5
5
Fig. 5.3 - 1 "Transport functions" screen
Key to Fig. 5.3 - 1
(1) Functions for the board conveying systems
(2) Functions for adjusting the transport conveyor width
(3) Functions to display state of the ultrasonic sensors
5
5
12
3