6 Vision functions User M anual SIPLACE S -23 HM 6.6 Test Component Software Version SR.406.xx 02/00 US Edition 282 Notes on using the transf ormation tables to set t he contrast sensitivity 6 – Selec t up to 3 s ections…
User Manual SIPLACE S-23 HM 6 Vision functions
Software Version SR.406.xx 02/00 US Edition 6.6 Test Component
281
Graphic presentation of the table 6
In the diagram 6
– the abscissae (x axis) represent the input values range, subdivided into sections.
– the ordinates (y axis) represent the output values with their color allocation.
Buttons 6
Å Accept
Click on the Accept button to save the settings. The option box will then close.
Å Cancel
With Cancel you can discard the settings. The option box will then close.
Å Help
With the Help button you can access explanatory material regarding the on-screen presenta-
tion.
Å Number input field
You can choose the number of sections
Å by entering the numerical value directly into the display field, or
Å by moving the scroll field in the scroll bar to the right or left using the mouse. In this way you
can run back and forth through the values range (1 - 5), or
Å by clicking on the lefthand or right-hand arrow on the scroll bar. In this way you can increase
or decrease the number of selections.
Programming the transformation table 6
Å Specifying the output values
Position the mouse pointer over the ends of the transformation lines of each section. The ends
are marked with small horizontal lines. A vertical double arrow will then appear on the screen.
Click on the lefthand mouse key and move the arrow upwards or downwards. This will move
the selected end of the transformation line and the numerical value will be displayed at OUT
Begin or OUT End.
Å Selecting the section limits
The graphical representation in Fig. 6.6 - 30 on page 280 shows equidistant section limits with
the ranges 0 - 80, 81 - 180 and so on. You can change these section limits if you wish. However
limits 0 and 255 are permanently allocated and cannot therefore be moved.
Position the mouse pointer on a section limit (but not 0 and 255). A horizontal double arrow will
appear on the screen. Hold down the lefthand mouse pointer and use it to drag the section limit
in the direction you want. The corresponding numerical value will be displayed at IN:.
Å Once you have programmed your transformation table you can quit the option box by clicking
on Accept or Cancel.

6 Vision functions User Manual SIPLACE S-23 HM
6.6 Test Component Software Version SR.406.xx 02/00 US Edition
282
Notes on using the transformation tables to set the contrast sensitivity 6
– Select up to 3 sections.
– The range of values for the individual sections should be at least 75.
– Program the ranges so that no jumps occur at the range limits.
Set the contrast sensitivity so that the shape of the curve roughly corresponds to one of the
three following examples:
Setting the contrast sensitivity to suppress defective structures 6
Å Select the following settings to suppress the defective structures that can start from bases, la-
bels, the body of components and nozzles, for example.
6
Fig. 6.6 - 31 Setting the contrast sensitivity to suppress defective structures

User Manual SIPLACE S-23 HM 6 Vision functions
Software Version SR.406.xx 02/00 US Edition 6.6 Test Component
283
Setting the contrast sensitivity to intensify the contrast for low-contrast components 6
Å Select the following settings for low-contrast components in order to intensify the contrast:
6
Fig. 6.6 - 32 Setting the contrast sensitivity to intensify the contrast for low-contrast components