Specification SIPLACE CF-Medium - 第27页

26 Technical D ata: Connections Connectio ns a nd E nergy R equ ire d Main v oltage requirement 230/400 V ∼ / 119/208 V ∼ ± 5%, 50/60 Hz Powe r 1.9 kW Circuit bre aker 3 x 16 A Power outag e max. 20 m s Compr essed air r…

100%1 / 31
25
Technical Data:
Signal Interfaces
2. PCB handling has started
Conveyor 1 is On Conveyor 2 is On
Transport Direction
Conveyor Section 1
Conveyor Section 2
Station n
delivers PCB
to station n+1
Station n+1
waits for PCB
from station n
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
PCB
Sensor
Transport Direction
Conveyor Section 1
PCB
Sensor
Conveyor Section 2
Station n
has just
delivered PCB
Station n+1
waits for PCB from
station n, but has
not received it
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
PCB
Sensor
3. PCB is at delivery
Conveyor 1 is Off Conveyor 2 is On
Conveyor 1 is Off Conveyor 2 is On
Transport Direction
Conveyor Section 1
PCB
Sensor
Conveyor Section 2
Station n Station n+1
has just received
the PCB
Requirement
Delivery
Permission
Receival
Requirement
Delivery
Permission
Receival
4. PCB transport is finished
A detailed documentation of the
PCB transport signal interface is
available on request.
26
Technical Data:
Connections
Connections and Energy Required
Main voltage requirement
230/400 V
/ 119/208 V
±
5%, 50/60 Hz
Power 1.9 kW
Circuit breaker 3 x 16 A
Power outage max. 20 ms
Compressed air requirements 5.5 - 10 bar, 400 Nl/min, ½" tube
Compressed Air Specification
Particles: max. particle size by density,
based on ISO/DIS 8573-1 Class
Particle size
Particle density
0.1 µm
0.1 mg/m³
Dew:
Pressure dewpoint
Dewpoint
Class 4
+ 3° C
Oil:
max. oil content
Particle density
Class 1
0.01 mg/m³
Pressure Supply
Power Supply:
3 m Cable with
CEKON-Connector 3 x 16A
PCB Transport-
direction
Signal Interface
LAN Supply
230 Inner Edge
Fixed Side of Transport
Feet
27
Technical Data:
Dimensions and Set-Up Conditions
Values
Length 1587 mm
Width excluding Waffle Pack Changer 2425 mm
Width including Waffle Pack Changer 2952 mm
Height from transport to warning lamp 1140 mm
Weight of basic module 1500 kg
Weight fully equipped excluding
Waffle Pack Changer 2000 kg
Weight fully equipped including
Waffle Pack Changer 2320 kg
Room temperature
Humidity
Between 15° and 35°C
30 - 80%, on average not higher
than 45%, so that no condensation
can ever form on the machine
Maximum noise development
74 dB
A
SIPLACE CF
1140
1140
252
252
740
740
1921
1921
2500
2952
1036
1036
1587
1587
350
Height of PCB transport
830
± 15 mm (standard)
900
± 15 mm (option)
930
± 15 mm (option)
950
± 15 mm (option) SMEMA
Foot height 120 mm
All units in mm
725