00198168-02_Technical_Training_TX-Series_EN - 第125页
5 Placement Heads 5.2 C&P20 P/M2 Head Technical Training SIPLACE TX-Series 10/2016 125 No. Code Error Description Possible Cause Action 9 30524 Cannot reference DP axis, segment: DP drive defect ● Inspect DP drive an…

5 Placement Heads
5.2 C&P20 P/M2 Head
124 Technical Training SIPLACE TX-Series 10/2016
5.2.9 Error List and Maintenance
5.2.9.1 Common Error List
No. Code Error Description Possible Cause Action
1 34439 Component present
before pick up
●
Nozzle dirty
●
Air kiss too low
●
Sticky component
●
Remove component and
clean/replace nozzle
●
Check air kiss circuit
●
Check relevant component
and exchange if necessary
34453 Component present
after placement
34459 Component present
after reject
34424 Cannot reject
component, segment:
2 34440 Component not
present after pick up
●
Nozzle leak /
vacuum low
●
Wrong nozzle
type
●
Components /
feeder not ready
●
Inspect nozzle and replace
it if necessary / check
vacuum accordingly
●
Inspect and replace
relevant nozzle
●
Check feeder status of
relevant component
3 34488 Placement head is
unable to continue
●
Head / axis issue
●
Components /
feeder not ready
●
Check error chain
messages, reference run
relevant head / axis
●
Check error chain
messages, check feeder
status and relevant
component
32570 Machine has stopped:
Placement head is
unable to continue
4 30820 Nozzle is not refer-
enced, segment:
●
Nozzle incorrect
●
DP drive problem
●
Check nozzle and replace
it if necessary
●
Check relevant DP drive,
execute reference run
5 34450 Component not
present before
placement
●
Worn nozzle /
leak
●
Holding vacuum
too low
●
Components /
feeder not ready
●
Inspect Nozzle and replace
it if necessary
●
Check holding vacuum
circuit accordingly
●
Check feeder status and
relevant component
6 32574 Machine has stopped:
Reference run has
failed
●
Head / axis issue
●
Wrong nozzle set
●
Implement reference run
for error inspection
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
7 33365 Nozzle dirty Dirty / worn nozzle
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
33367 Nozzle worn
8 30480 Component sensor
soiled
Defective / dirty
component sensor
●
Inspect component sensor,
clean or replace it if
necessary
30728 Component sensor
coated
30821 Component sensor is
heavily soiled

5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 125
No. Code Error Description Possible Cause Action
9 30524 Cannot reference DP
axis, segment:
DP drive defect
●
Inspect DP drive and
replace it if necessary
●
Check error chain
messages
10 30573 Skipping segment after
positioning error,
segment:
●
DP drive high
temp
●
DP drive defect
●
Try to enable relevant DP
drive, Inspect DP drive and
replace it if necessary
●
Check error chain
messages
11 30624 Nozzle scan failed
●
Dirty nozzle
●
Air kiss too low
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
●
Check air kiss circuit
34401 Cannot scan nozzle
33368 Nozzle scanning
unsuccessful
5.2.9.2 Maintenance
Maintenance task Twin Interval Equipment required
Cleaning the return cylinder Workflow 2
●
Cleaning Sticks
●
Universal placement head mounting rack
Cleaning the Z Axis Workflow 2
●
Anti-static tweezers, Bernstein 5-192
●
Torque Screwdriver ESD 1,0-5,0 Nm
●
Hexagon Socket Head CAP Screw Driver
●
Universal placement head mounting rack
●
silicone hose D12 L20mm
●
Allen key insert - 2,5
Lubricating the DP segment
guidance
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
●
Cleaning Sticks
●
Multipette M4
●
Combitips advanced 0,1 ml blue
Lubricating the Z Axis linear
guidance
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Multipette M4
●
Combitips advanced 0,1 ml blue
●
silicone hose D12 L20mm
Lubricating the C&P20P DP
drive bearing
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Klueberalfa DH 3-100, 50ml (black)
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Multipette M4
●
Combitips advanced 0,1 ml black
Cleaning the DP reflection
area
Workflow 2
●
Isopropanol
●
Cleaning Sticks

5 Placement Heads
5.2 C&P20 P/M2 Head
126 Technical Training SIPLACE TX-Series 10/2016
Maintenance task Twin Interval Equipment required
Exchanging the aperture ring
(vacuum pump)
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Universal placement head mounting rack
●
Torque Screwdriver ESD 0,1-0,6 Nm
●
Allen key insert wiha - 2,5
●
Cover pre-assembled C&P20P
●
Orifice plate pre-assembled C&P20 P
Cleaning and lubricating the
race way
Workflow 2
●
Lamora D 220
●
Cleaning Sticks
●
silicone hose D12 L20mm
●
Torque Screwdriver ESD 0,1-0,6 Nm
●
Allen key insert wiha - 2,5
●
Cover pre-assembled C&P20 P
Cleaning the component
sensor
Workflow 2
●
Isopropanol
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Protective cover CO sensor C&P20 P
Replacing the filter discs Workflow 2
●
Universal placement head mounting rack
●
Filter disc removal device /C&P20 P
●
Filterdisc kpl. C&P20 P
●
Nozzle 4245 Calibration nozzle
Remove maintenance label,
clean this area and attach
new label with actual date
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Isopropanol
●
Maintenancelabel C&P20 P 10 pcs.
●
CD-marker edding 8400
●
Point Pliers 140mm OVAL
For detailed information refer to the Maintenance Job Card for C&P20P Heads.