00198168-02_Technical_Training_TX-Series_EN - 第126页
5 Placement Heads 5.2 C&P20 P/M2 Head 126 Technical Training SIPLACE TX-Series 10/2016 Maintenance task Twin Interval Equipment required Exchanging the aperture ring (vacuum pump) Workflow 2 ● Cleaning Wipe, KM-Wipe …

5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 125
No. Code Error Description Possible Cause Action
9 30524 Cannot reference DP
axis, segment:
DP drive defect
●
Inspect DP drive and
replace it if necessary
●
Check error chain
messages
10 30573 Skipping segment after
positioning error,
segment:
●
DP drive high
temp
●
DP drive defect
●
Try to enable relevant DP
drive, Inspect DP drive and
replace it if necessary
●
Check error chain
messages
11 30624 Nozzle scan failed
●
Dirty nozzle
●
Air kiss too low
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
●
Check air kiss circuit
34401 Cannot scan nozzle
33368 Nozzle scanning
unsuccessful
5.2.9.2 Maintenance
Maintenance task Twin Interval Equipment required
Cleaning the return cylinder Workflow 2
●
Cleaning Sticks
●
Universal placement head mounting rack
Cleaning the Z Axis Workflow 2
●
Anti-static tweezers, Bernstein 5-192
●
Torque Screwdriver ESD 1,0-5,0 Nm
●
Hexagon Socket Head CAP Screw Driver
●
Universal placement head mounting rack
●
silicone hose D12 L20mm
●
Allen key insert - 2,5
Lubricating the DP segment
guidance
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
●
Cleaning Sticks
●
Multipette M4
●
Combitips advanced 0,1 ml blue
Lubricating the Z Axis linear
guidance
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Lubcon Thermoplex ALN 1001/00, 50ml (blue)
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Multipette M4
●
Combitips advanced 0,1 ml blue
●
silicone hose D12 L20mm
Lubricating the C&P20P DP
drive bearing
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Klueberalfa DH 3-100, 50ml (black)
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Multipette M4
●
Combitips advanced 0,1 ml black
Cleaning the DP reflection
area
Workflow 2
●
Isopropanol
●
Cleaning Sticks

5 Placement Heads
5.2 C&P20 P/M2 Head
126 Technical Training SIPLACE TX-Series 10/2016
Maintenance task Twin Interval Equipment required
Exchanging the aperture ring
(vacuum pump)
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Universal placement head mounting rack
●
Torque Screwdriver ESD 0,1-0,6 Nm
●
Allen key insert wiha - 2,5
●
Cover pre-assembled C&P20P
●
Orifice plate pre-assembled C&P20 P
Cleaning and lubricating the
race way
Workflow 2
●
Lamora D 220
●
Cleaning Sticks
●
silicone hose D12 L20mm
●
Torque Screwdriver ESD 0,1-0,6 Nm
●
Allen key insert wiha - 2,5
●
Cover pre-assembled C&P20 P
Cleaning the component
sensor
Workflow 2
●
Isopropanol
●
Cleaning Sticks
●
Universal placement head mounting rack
●
Protective cover CO sensor C&P20 P
Replacing the filter discs Workflow 2
●
Universal placement head mounting rack
●
Filter disc removal device /C&P20 P
●
Filterdisc kpl. C&P20 P
●
Nozzle 4245 Calibration nozzle
Remove maintenance label,
clean this area and attach
new label with actual date
Workflow 2
●
Cleaning Wipe, KM-Wipe
●
Isopropanol
●
Maintenancelabel C&P20 P 10 pcs.
●
CD-marker edding 8400
●
Point Pliers 140mm OVAL
For detailed information refer to the Maintenance Job Card for C&P20P Heads.

5 Placement Heads
5.2 C&P20 P/M2 Head
Technical Training SIPLACE TX-Series 10/2016 127
5.2.10 Excercise: C&P20 P Head
1. During reference run the difference between open/close vacuum values for segment 2
is too low, what could be the possible reason?
A PRV is defective.
B Holding circuit vacuum is soiled.
C The nozzle soiled or wrong type.
D Holding circuit vacuum measurement board is defect.
2. Which of the following describes best the function of the component sensor?
A To measure the nozzle height.
B To monitor the presence and/or component height after pickup and before placement.
C To determine Z Axis movement.
D All of the above.
3. Which of the following is false?
A The function of the retract unit is to prevent the Z Axis from sliding down and getting dam-
aged after power off
B The Z Axis end signal is triggered by bottom light sensor, no matter what placement mode
for CPP Head.
C The function of the component camera is component recognition and to determine the exact
position of component on nozzle
D The function of the PRV is to supply vacuum and air kiss during Pickup/Place process.
4. What are the differences between C&P20 P and C&P20 M2
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………
………………………………………………………………………………………………………