00198168-02_Technical_Training_TX-Series_EN - 第226页

9 Control and Communication 9.8 FCU 226 Technical Training SIPLACE TX-Series 10/2016 9.8 FCU The FCUs (Feeder Control Unit) on TX machines has the basically functionality: ● Communication with the feeders and docking of …

100%1 / 266
9 Control and Communication
9.6 Network Construction
Technical Training SIPLACE TX-Series 10/2016 225
9.6 Network Construction
Network Construction
IP address Subnet mask Comment
SIPLACE Lan 172.22.xxx.xxx 255.255.0.0 LAN connection on the
computer
CIN 192.168.255.239 255.255.255.224 LAN connection on the
computer
Station computer 192.168.255.249 255.255.255.224
9.7 Axis Control
Axis Control
9 Control and Communication
9.8 FCU
226 Technical Training SIPLACE TX-Series 10/2016
9.8 FCU
The FCUs (Feeder Control Unit) on TX machines has the basically functionality:
Communication with the feeders and docking of the COT.
Control of the tape cutter (moving the pneumatic cylinders in and out, status query of the
sensors).
Nozzle changers detection and the nozzle station (forced air valve for the C&P20 and CPP)
control.
Query of the sensors for the component/nozzle reject boxes.
During production with (SW1= OFF) the reject bin is recognized by the sensor and signalized by
the LED.
The FCU need to be addressed for the TX see diagram below:
Switch settings
ON OFF
SW1 Test mode for reject bins deactivated Test mode for reject bins activated
SW2 60 Fold FCU 40 Fold FCU
SW3 Without insert control with virtual button With insert control without virtual button
SW4 HW version 8 with tape cutter and nozzle
changer functions
HW version without tape cutter and nozzle
changer functions
9 Control and Communication
9.9 Feeder Communication
Technical Training SIPLACE TX-Series 10/2016 227
Control and Communication – FCU Overview
9.9 Feeder Communication
The communication between the Feeder Control Unit (FCU) and the X-feeders is carried out via an
internal CAN bus.
This CAN bus is only responsible for the communication between the FCU and the feeders and is
controlled by the machine CAN bus.
The data and power supply from the FCU to each feeder is contactless.