10 Station Software Overviews
10.7 Maintenance GUI
248 Technical Training SIPLACE TX-Series 10/2016
Verification – Conveyor Rail Verification
This function check the parallelism of the
conveyor rails with the PCB cameras and the
outer edge of each rail in the placement area.
Verification – Conveyor Motor Verification
This function to verify the transport motors
depending on the current and the defined limits.
Example/ Extract of the report.
Verification – Power Supply (SMPS)
This is the common function for the power sup-
ply (SMPS) and is available for X-Series S and
SX machine with X-module upgrade and all TX
machine.

10 Station Software Overviews
10.7 Maintenance GUI
Technical Training SIPLACE TX-Series 10/2016 249
Verification – Feeder Verification
This function is to verify the feeder pick up
position at the machine.
The machine takes a picture of the real pickup
position without offsets, so that the user can see
if the drive system matches the pickup position.

10 Station Software Overviews
10.7 Maintenance GUI
250 Technical Training SIPLACE TX-Series 10/2016
10.7.4.1 Power Supply Diagnostics GUI
The diagnostics function can be accessed as follows:
1. Click on to the maintenance GUI icon
2. Click on Verification icon
3. Click on the "Power supply" button and the
main menu opens
This window shows the diagnostics data main view:
1. Main view SMPS data from PS1 and CAP1
2. CSB shows the status of all safety signals
from the safety breaker
3. Data for the 160 VDC
4. Data for the 42 VDC
5. Data for the 28 VDC
6. Data for the 24 VDC
7. Data for PS1 and CAP1
If the start button has not yet been pressed, there is no switched voltage present here yet and the
switched voltages icons are highlighted red:
1. Overview voltages status
2. Number of voltage drops since last reset
3. Reset voltage drop counter
NOTICE
All signals or voltages which are interrupted when pressing the emergency stop button or
opening the machine covers will be counted by the voltage drop counter.