00198168-02_Technical_Training_TX-Series_EN - 第84页
5 Placement Heads 5.1 CPP Head 84 Technical Training SIPLACE TX-Series 10/2016 No. Code Error Description Possible Cause Action 9 30524 Cannot reference DP axis, segment: DP drive defect ● Inspect DP drive and replace it…

5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 83
5.1.9 Error List and Maintenance
5.1.9.1 Common Error List
No. Code Error Description Possible Cause Action
1 34439 Component present
before pick up
●
Nozzle dirty
●
Air kiss too low
●
Sticky component
●
Remove component and
clean/replace nozzle
●
Check air kiss circuit
●
Check relevant component
and exchange if necessary
34453 Component present
after placement
34459 Component present
after reject
34424 Cannot reject
component, segment:
2 34440 Component not
present after pick up
●
Nozzle leak / va-
cuum low
●
Wrong nozzle
type
●
Components /
feeder not ready
●
Inspect nozzle and replace
it if necessary / check
vacuum accordingly
●
Inspect and replace
relevant nozzle
●
Check feeder status of
relevant component
3 34488 Placement head is un-
able to continue
●
Head / axis issue
●
Components /
feeder not ready
●
Check error chain
messages, reference run
relevant head / axis
●
Check error chain
messages, check feeder
status and relevant
component
32570 Machine has stopped:
Placement head is
unable to continue
4 30820 Nozzle is not refer-
enced, segment:
●
Nozzle incorrect
●
DP drive problem
●
Check nozzle and replace
it if necessary
●
Check relevant DP drive,
execute reference run
5 34450 Component not
present before
placement
●
Worn nozzle /
leak
●
Holding vacuum
too low
●
Components /
feeder not ready
●
Inspect Nozzle and replace
it if necessary
●
Check holding vacuum
circuit accordingly
●
Check feeder status and
relevant component
6 32574 Machine has stopped:
Reference run has
failed
●
Head / axis issue
●
Wrong nozzle set
●
Implement reference run
for error inspection
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
7 33365 Nozzle dirty Dirty / worn nozzle
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
33367 Nozzle worn
8 30480 Component sensor
soiled
Defective / dirty
component sensor
●
Inspect component sensor,
clean or replace it if
necessary
30728 Component sensor
coated
30821 Component sensor is
heavily soiled

5 Placement Heads
5.1 CPP Head
84 Technical Training SIPLACE TX-Series 10/2016
No. Code Error Description Possible Cause Action
9 30524 Cannot reference DP
axis, segment:
DP drive defect
●
Inspect DP drive and
replace it if necessary
●
Check error chain
messages
10 30573 Skipping segment after
positioning error,
segment:
●
DP drive high
temp
●
DP drive defect
●
Try to enable relevant DP
drive, Inspect DP drive and
replace it if necessary
●
Check error chain
messages
11 30624 Nozzle scan failed
●
Dirty nozzle
●
Air kiss too low
●
Inspect nozzle and replace
it if necessary
●
Check error chain
messages
●
Check air kiss circuit
34401 Cannot scan nozzle
33368 Nozzle scanning
unsuccessful

5 Placement Heads
5.1 CPP Head
Technical Training SIPLACE TX-Series 10/2016 85
5.1.9.2 CPP Head - Maintenance
Maintenance task Multistar CPP Interval Equipment required
Replacing the Pressure Control Valve Workflow 3
●
Torque screwdriver ESD 0,4 – 1,0Nm
●
Torque allen swap blade 2mm
●
Torque allen swap blade 3mm
Check/replace the silencer Workflow 3
●
Silencer CPP
Cleaning the Holding Circuit Housing Workflow 3
●
Anti-static tweezers, Bernstein 5-192
●
Gasket Kit Retaining Circle/CPP
●
Cleaning sticks
●
Cleaning wipe, KM-wipe
Replacing the O-Rings Holding Circuit Workflow 3
●
Double wrenches size 17x19
●
Torque screwdriver ESD 0,1-0,6Nm
●
Torque allen swap blade 1,5mm
Cleaning the Screwed Joint Workflow 3
●
Anti-static tweezers Bernstein 5-192
●
Gasket Kit Retaining Circle/CPP
●
Cleaning wipe, KM-wipe
Only required for heads with service
hole at the inside of the front plate
Workflow 3
●
Multipette M4
●
Combitips advanced 0,1ml yellow
●
Cleaning wipe, KM-wipe
●
Klueberoil GEM 1 220N 50ml (yellow)
Oiling the Z Axis Linear Guide Workflow 3
●
Multipette M4
●
Combitips advanced 0,1ml blue
●
Torque screwdriver ESD 0,4-1,0Nm
●
Torque allen swap blade 2mm
●
Cleaning wipe, KM-wipe
●
Lubcon Thermoplex ALN 1001/00,
50ml (blue)
●
Cleaning sticks
Checking/Replacing the DP Vacuum
Hoses
Workflow 3
●
Point Pliers 140mm oval
●
Hose Dp / CPP 12x
Cleaning the Light Barrier on the DP
Drive
Workflow 3
●
Anti-static tweezers
●
Bernstein 5-192
●
Isopropanol
●
Cleaning sticks
●
SM Role labels 9x5 black flat
Oiling the DP Segment Guide Workflow 3
●
Multipette M4
●
Combitips advanced 0,1ml blue
●
Cleaning wipe, KM-wipe
●
Lubcon Thermoplex ALN 1001/00,
50ml (blue)
●
Cleaning sticks