SPF维修.pdf - 第110页
6.4 Dip Switch Content List SERVICE MANUAL SPF 6.4−1 D54SEC−85−020−B0 6.4 Dip Switch Content List D54SEC−85−020−B0 Sentence No. (1) MMC, DIP−SW1 SW No. Functions ON OFF Standard setting 1 RAM clear V alid Invalid OFF 2 N…

SPF
6.3 ROM Parameter List
SERVICE MANUAL
6.3−4
D54SEC−85−010−A0
LOOP2
Axis No. 5 6 7 8
Axis name SCR SCX SY SQ
Capacity 50W 50W 750W 200W
AC servo driver type No. 005MSGF 005MSGF 075MSGB 020MSGJ
No. Items − − − −
20 Position loop gain 40 40 50 40
21 Speed feed forward 0 0 0 0
22 Manufacturer use 10 10 10 10
23 Position deviation over setting 1875 1875 1875 1875
24 Position deviation over abnormal invalid 0 0 0 0
25 Manufacturer use 10000 10000 10000 10000
26 Manufacturer use 10000 10000 10000 10000
27 Position loop gain step 20 20 10 20
28 Speed feed forward step 5 5 5 5
29 Manufacturer use 0 0 0 0
2A Constant in torque filter 10 10 10 ® 20 50 ® 20
2B Feed forward filter 0 0 0 0
2C − 0 0 0 0
2D − 0 0 0 0
2E − 0 0 0 0
2F − 0 0 0 0
30 Second speed loop gain 100 100 30 ® 50 100
31 Second loop integral gain 50 50 200 50
32 Second position loop gain 40 40 690 ® 50 40
33 Second gain setting 11 11 11 11
34 Second gain changeover time setting 0 0 0 0
35 − 0 0 0 0
36 Smoothing filter 0 0 0 0
37 Manufacturer use 0 0 0 0
38 Second gain continuos time setting 50 50 50 50
39 SPM selection 0 0 0 0
3A IM selection 2 2 2 2
3B Speed monitor full scale value 5000 5000 5000 5000
3C Torque monitor full scale value 2000 2000 1500 1750
3D Deviation monitor full scale value 100 100 100 100
3E Manufacturer use 0 0 0 0
3F − 0 0 0 0

6.4 Dip Switch Content List
SERVICE MANUAL
SPF
6.4−1
D54SEC−85−020−B0
6.4 Dip Switch Content List
D54SEC−85−020−B0
Sentence No.
(1) MMC, DIP−SW1
SW No.
Functions ON OFF
Standard
setting
1 RAM clear Valid Invalid OFF
2 Not used OFF
3 Not used OFF
4 Not used OFF
5 Not used OFF
6 Not used OFF
7 Not used OFF
8 Not used OFF
DIP−SW2
SW No.
Functions ON OFF
Standard
setting
1 Not used OFF
2 Not used OFF
3 Not used OFF
4 Not used OFF
5 Automatic width control Valid Invalid OFF
6 Maintenance switch Valid Invalid ON
7 Not used OFF
8 ROM ® RAM copy Valid Invalid ON
DIP−SW3
SW No.
Functions ON OFF
Standard
setting
1
EP
ROM
capacity
selection
Refer
to
table
A
OFF
2
EP
ROM
capac
it
yse
l
ec
ti
on
R
e
f
er
t
o
t
a
bl
e
A
OFF
3 Watchdog timer Valid Invalid OFF
4 Not used OFF
Table A
SW No.
Functions
1 2
F
unc
ti
ons
OFF OFF 1M
OFF ON 2M
ON ON 4M

SPF
6.4 Dip Switch Content List
SERVICE MANUAL
6.4−2
D54SEC−85−020−B0
(2) MMI, DIP−SW1
SW No.
Functions ON OFF
Standard
setting
1 Not used Not used Not used OFF
2 Display Liquid crystal CRT ON
3 Not used Not used Not used OFF
4 Not used Not used Not used OFF
5 Password function Valid Invalid OFF
6 FD format IBM NEC OFF
7 RAM boot Valid Invalid OFF
8 Bus access Master Slave OFF
(3) SC, DIP−SW1
SW No.
Functions ON OFF
Standard
setting
1 Compile selection EP.ROM F.ROM ON
2 OFF
3
Mode selection Refer to table B
OFF
4 OFF
Table B
No.
Functions
2 3 4
F
unc
ti
ons
OFF OFF OFF Standard
ON OFF OFF Hard timer 1msec
OFF ON OFF Not defined
ON ON OFF Not defined
OFF OFF ON Not defined
ON OFF ON Not defined
OFF ON ON Not defined