SPF维修.pdf - 第113页

SPF 6.4 Dip Switch Content List SERVICE MANUAL 6.4−4 D54SEC−85−020−B0 = MEMO =

100%1 / 160
6.4 Dip Switch Content List
SERVICE MANUAL
SPF
6.4−3
D54SEC−85−020−B0
DIP−SW2
SW No.
Functions ON OFF
Standard
setting
1 Operation mode selection Refer to table C Regular start up OFF
2 Option 5 Option 1 OFF
3
Division
compile
designation
Option 6 Option 2 OFF
4
Di
v
i
s
i
on comp
il
e
d
es
i
gna
ti
on
Option 7 Option 3 OFF
5 Option 8 Option 4 OFF
6 OFF
7
Division compile designation Refer to table D
OFF
8
p
g
OFF
Table D
No.
Functions
6 7 8
F
unc
ti
ons
OFF OFF OFF Division compile Invalid
ON OFF OFF Select special specification 1
OFF ON OFF Select special specification 2
ON ON OFF Select special specification 3
OFF OFF ON Select special specification 4
ON OFF ON Select special specification 5
OFF ON ON Select special specification 6
ON ON ON Select 2−port RAM (Select from MMC)
Table C
No.
Functions
1 2 3 4 5 6 7 8
F
unc
ti
ons
ON OFF OFF OFF OFF ON ON ON Self check
ON ON ON ON ON ON ON ON System download
DIP−SW3
SW No.
Functions ON OFF
Standard
setting
1 Optical loop 0 error interrupt Valid Invalid OFF
2 Optical loop 1 error interrupt Valid Invalid OFF
3 Optical loop 2 error interrupt Valid Invalid OFF
4 Optical loop 3 error interrupt Valid Invalid OFF
5 Wired subcontroller error interrupt Valid Invalid OFF
6 Not used OFF
7 Not used OFF
8 EP. ROM capacity 1M 256k OFF
SPF
6.4 Dip Switch Content List
SERVICE MANUAL
6.4−4
D54SEC−85−020−B0
= MEMO =
6.5 SC Timer Table
SERVICE MANUAL
SPF
6.5−1
D54SEC−85−030−B0
6.5 SC Timer Table
D54SEC−85−030−B0
Sentence No.
No. Name
Setting
value
SC address Remarks
TM01 Table belt OFF (Reference) 0.30 5300
When corresponding to end
face 3mm, M0.7 XL1.0
TM02 Rear readjustment stability 0.20 5301
TM03 Vacuum stability 0.20 5302
TM04 Vacuum OFF 0.10 5303
TM05 While carrying out 1.00 5304
TM06 Safety restart 0.50 5305
TM07 SST axis operation 1.00 5306
TM08 Blower motor ON 0.50 5307
TM09 Cleaner nozzle ascend timer 0.20 5310
TM10 Winding completion 0.50 5311
TM11 Maintenance circuit failure 0.50 5312
TM12
Support ascend (Valid when end
face positioning)
0.05 5313
TM13 ST axis brake 0.50 5314
TM14
Warp prevention descend (valid
when pin positioning)
0.20 5315
TM15 Flicker 1 0.50 5316
TM16 Flicker 2 0.50 5317
TM17 Loader transfer error 10.00 5320
TM18 Table transfer error 10.00 5321
TM19 Unloader transfer error 10.00 5322
TM20 Count up 3.00 5323 For LM−V
TM21
Parts transfer detection OFF
(Carrying in)
0.10 5324
TM22 Reference pin error 10.00 5325
TM23 Resolvent dispensing ON time 0.03 5326
Resolvent dispensing valve
signal ON time
TM24 Winding error 99.00 5327
TM25 PCB wait (Loader) 15.00 5330
TM26 P board detection 3 pass 0.20 5331
TM27 Positioning 2 descent timer 0.20 5332
TM28 Resolvent dispensing OFF time 0.01 5333
Resolvent dispensing valve
signal OFF time
TM29 Cleaner connection descent error 5.00 5334
TM30 Blower motor high speed 6.00 5335
TM31 PCB wait (Unloader) 15.00 5336
TM32 Carrying in wait timer 0.00 5337