SPF维修.pdf - 第137页
SPF 6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL 6.7−6 D54SEC−85−080−A0 6.7.4 SC T imer MANUAL : 1BLOCK <<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX F1 F2 F3 F4 F5 F6 F7 F8 [SC TIMER] EXI…

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−5
D54SEC−85−080−A0
R COMMAND
· This is a designation of whether the R command is outputted to the host computer or not.
YES : The R command is output to the host.
NO : The R command is not output to the host.
MOMENTARY
· Select whether duplicate M, T, X, or Y commands are omitted when the C1 command outputs NC data to
the host.
YES : The M, T, X and Y commands in each block are omitted if they are the same.
NO : The M, T, X and Y commands in each block are not omitted even if they are the same.
TIME OUT
· This is a designation of whether the time out is performed or not.
YES : A time out is not performed.
NO : A time out is performed.
END COMMAND
· This is a designation of whether ETX or CR is used as the message end command.
ETX: ETX becomes the message end command.
CR : CR becomes the message end command.
BAUD RATE
· This is a designation of the data transmission speed.
2400 : The data transmission speed is 2400 [bps].
4800 : The data transmission speed is 4800 [bps].
9600 : The data transmission speed is 9600 [bps].
19200 : The data transmission speed is 19200 [bps].

SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−6
D54SEC−85−080−A0
6.7.4 SC Timer
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[SC TIMER]
EXIT
INITIAL
PREVIOUS
PAGE
NEXT
PAGE
0.30
1.00
0.50
10.00
15.00
15.00
0.20
0.20
0.20
0.50
0.20
0.20
0.20
0.00
0.20
0.20
0.10
0.50
0.50
10.00
0.01
0.03
0.20
0.20
0.20
0.50
0.50
1.00
0.20
0.10
0.20
0.20
1.00
0.50
10.00
0.03
0.60
0.20
0.20
0.20
TM02
TM08
TM14
TM20
TM26
TM32
TM38
TM44
TM01
TM07
TM13
TM19
TM25
TM31
TM37
TM43
TM03
TM09
TM15
TM21
TM27
TM33
TM39
TM45
TM04
TM10
TM16
TM22
TM28
TM34
TM40
TM46
0.50
0.05
10.00
99.00
6.00
0.03
0.20
0.20
TM06
TM12
TM18
TM24
TM30
TM36
TM42
TM48
TM05
TM11
TM17
TM23
TM29
TM35
TM41
TM47
Figure 6.7−5−SC timer screen
Parameter explanation
SC timer
· This is a setting of SC timer.
F1 : The setting is initialized.
F6 : Return to previous page.
F7 : Go to next page.
F8 : Setting is completed.
=REFERENCE=
Referto’SCTimerTable’.

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−7
D54SEC−85−080−A0
F1
F2 F3 F4 F5 F6
F7 F8
CT02
CT08
CT14
CT20
CT01
CT07
CT13
CT19
25
0
50
0
27
100
100
0
CT03
CT09
CT15
500
0
10
CT04
CT10
CT16
5
0
0
CT06
CT12
CT18
2
500
10
CT05
CT11
CT17
100
0
0
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
[SC COUNTER]
EXIT
INITIAL
PREVIOUS
PAGE
NEXT
PAGE
Figure 6.7−6−SC counter
Parameter explanation
SC counter
· This is a setting of SC counter.
F1 : The setting is initialized.
F6 : Return to previous page.
F7 : Go to next page.
F8 : Setting is completed.