SPF维修.pdf - 第139页
SPF 6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL 6.7−8 D54SEC−85−080−A0 6.7.5 Driver Gain Setting MANUAL : 1BLOCK <<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX F1 F2 F3 F4 F5 F6 F7 F8 [DRI…

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−7
D54SEC−85−080−A0
F1
F2 F3 F4 F5 F6
F7 F8
CT02
CT08
CT14
CT20
CT01
CT07
CT13
CT19
25
0
50
0
27
100
100
0
CT03
CT09
CT15
500
0
10
CT04
CT10
CT16
5
0
0
CT06
CT12
CT18
2
500
10
CT05
CT11
CT17
100
0
0
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
[SC COUNTER]
EXIT
INITIAL
PREVIOUS
PAGE
NEXT
PAGE
Figure 6.7−6−SC counter
Parameter explanation
SC counter
· This is a setting of SC counter.
F1 : The setting is initialized.
F6 : Return to previous page.
F7 : Go to next page.
F8 : Setting is completed.

SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−8
D54SEC−85−080−A0
6.7.5 Driver Gain Setting
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[DRIVER GAIN SETTING]
EXIT
INITIAL
POSITION FEEDBACK 1st : 0 to 255 2nd : 0 to 255
CX
CY
ST
SST
SCR
SCX
SY
SQ
POSITION FEEDB.
FEED
FORWARD
SPEED FEEDBACK
9
8
28
12
5
4
8
10
20
13
28
9
3
4
10
9
INTEGRAL OF SPD
0
0
0
0
0
0
0
0
20
20
21
20
20
5
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
CHANGE
TIMING
1st 2nd
1st 2nd
1st 2nd
DATA
TRANSFER
9
8
28
12
4
3
8
10
20
13
28
9
2
3
4
9
Figure 6.7−7−Driver gain setting screen
Parameter explanation
· This is a designation of setting the driver gain.
F1 : Transfer the data.
F2 : All driver gain setting are initialized.
F8 : Setting is completed.
=REFERENCE=
Referto’MAINTENANCEGUIDE(CONTROLS)/ACServoGainAdjustment’inthismanual.

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−9
D54SEC−85−080−A0
6.7.6 Optional Switch Setting
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[SETS OPTION SWITCH]
EXIT
DISPLAY : INVALID VALID
SC SW
OPTION SW
7654 3210
0000 0000
0000 0000
0000 0000
0000 0000
COMMENT
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1
2
3
OPTION PARAMETER
1
2
3
4
5
6
7
8
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Figure 6.7−8−Optional switch setting screen
Parameter explanation
· This is a designation of setting the optional switch.
· The values in the left side line of option parameter designate the offset values of electric air pressure
regulator and the values in the right side line designate the tilt values of electric air pressure regulator.
Option parameter 1 : Compressed cylinder
Option parameter 2 : Self−weight cancel cylinder
F8 : Setting is completed.