SPF维修.pdf - 第145页
SPF 6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL 6.7−14 D54SEC−85−080−A0 6.7.9 Recognition Service MANUAL : 1BLOCK <<MACHINE INITIAL SETTING>> XXXX−XX−XX XX : XX F1 F2 F3 F4 F5 F6 F7 F8 […

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−13
D54SEC−85−080−A0
6.7.8 Width Initial Data
SELECT USING AND ENTER.
No. 1
No. 2
No. 3
No. 4
No. 5
No. 6
EXIT
AXIS NAME
0: NOT USE
[WIDTH INITIAL DATA]
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6 F7 F8
¯ ¬ ®
AXIS
NO.
SPEED
HIGH ACCEL
XY
ORGN
COUP
LING
DR
CT
TEACH
AXIS
AXIS
TYPE
TEACH
DRCT
LMT
SIZE
RESO
LUTION
1 : GUIDE_RAIL
5 : L. CONV_RAIL
2 : POSI. _PIN
6 : UN. CONV_RAIL
3 : LOADER_RAIL
4 : UNLOAD._RAIL
3
1
4
0
0
4
15
15
15
0
0
16
1
1
1
0
0
0
5
5
5
0
0
5
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
0
2
0
0
0
0
0
0
3
3
3
0
0
3
10.00
10.00
10.00
0.00
0.00
2.77
0
0
0
0
0
0
AXIS
NAME
Figure 6.7−12−Width initial data setting screen
Parameter explanation
· This is a setting of the width initial data.
F8 : Setting is completed.

SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−14
D54SEC−85−080−A0
6.7.9 Recognition Service
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX : XX
F1
F2 F3 F4 F5 F6
F7 F8
[RECOGNITION SERVICE]
COMPLETE
SELECT DATA TO SET BY USING F KEYS
F1
CAMERA SELECT (PCB CAMERA, SCREEN CAMERA)
F 2 DISP MODE SELECTION (ORIGINAL, BINARY LEVEL / NEGATIVE DISP)
F 3 BRIGHTNESS (DISPLAY FOR X and Y AXIS)
CAMERA
SELECT
DISPLAY
MODE
F 4 CAMERA BRIGHTNESS CHECK
BRIGHTNESS
DISPLAY
CAMERA
BRT CHK
Figure 6.7−13−Recognition service screen
Parameter explanation
· This is a designation of which function keys to execute upon the selection.
F1 : Camera selection
F2 : Display mode selection
F3 : Brightness display
F4 : Camera brightness check
F8 : The screen returns to the upper level.

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−15
D54SEC−85−080−A0
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2
F3 F4 F5
F6
F7 F8
[RECOGNITION SERVICE]
COMPLETE
PCB CAMERA
SCREEN
CAMERA
PCB CAMERA
DISPLAY MODE
ORIGINAL DISP
POSITIVE
RING
LIGHT TYPE
CAMERA
LIGHT
SELECT
DISPLAY
MODE
F1
F2
F4
TO SELECT PCB CAMERA
TO SELECT DISPLAY MODE
SCREEN CAMERA
Figure 6.7−14−Recognition service screen
Parameter explanation
CAMERA
· This is a designation of which camera is used.
F1 : PCB camera is used.
F2 : Screen camera is used.
F4 : Display mode is set.
F7 : The light is exchanged.
F8 : The screen returns to the upper level.