00192216-01.pdf - 第42页
2 Retrofitting Instructions for Ceramic Substrate Centering Unit (O ptional) SIPLACE 80 S-20 / S-23HM/ F4 / F4-6 / F5 2.3 Retrofit Kit, Tools 04/2000 Issue 42 2.3 Retrofit Kit, T ools 5HWURILW.LW Ceramic su bstrat…

SIPLACE 80 S-20 / S-23HM/ F4 / F4-6 / F5 2 Retrofitting Instructions for Ceramic Substrate Centering Unit (Optional)
04/2000 Issue 2.2 Safety Instructions
41
'HILQLWLRQV
DANGER
in terms of these instructions means that death, severe bodily injury or considerable material dam-
age WILL occur if the instructions about danger are not followed.
2
2
WARNING
in terms of these instructions means that death, severe bodily injury or considerable material dam-
age may occur if the warnings are not heeded. 2
2
CAUTION
in terms of these instructions mean that minor bodily injury or material may occur if the cautions
are not heeded. 2
2
NOTE
in terms of these instructions is a statement of important information about the product or the
pertinent portion of the instructions to which particular attention is being drawn. 2

2 Retrofitting Instructions for Ceramic Substrate Centering Unit (Optional) SIPLACE 80 S-20 / S-23HM/ F4 / F4-6 / F5
2.3 Retrofit Kit, Tools 04/2000 Issue
42
2.3 Retrofit Kit, Tools
5HWURILW.LW
Ceramic substrate centering unit for the SIPLACE PCB Handling,
item no.: 00116814-02, type 2, consisting of:
- Rocker with clamping element, installed (for movable conveyor side)
- Holddown with rocker actuator, installed (for movable conveyor side)
- Guide, short
- Holddown for stationary conveyor side
- Guide assembly, RH side (fasten with the screws previously removed)
- Slide assembly, X-direction, incl. proximity switch and compressed air connection
- Cable for proximity switch, with connector
- Cable for solenoid valve, with solenoid valve connector
- Compressed air hose
- Valve for ceramic substrate centering unit (required when installing a 2nd centering unit)*
*) As standard, there is a solenoid valve on the back of the compressed air unit (see Fig.
2.4.4).
- Green plastic rail
Used if the substrate is only to be centered in the Y-direction.
NOTE:
The components indicated under "Additional Material Required" are not included in the retrofit kit.
$GGLWLRQDO0DWHULDO5HTXLUHG
3HUFHUDPLFVXEVWUDWHFHQWHULQJXQLW
– AMPMODU contact BU 0.12 - 0.56 mm item no. 00304845 2 each per solenoid valve
and 2 each per proximity
switch
– AMPMODU connector Bu 2 x 3-pin *) item no. 00304916 1 each per solenoid valve
and per proximity switch
– AMP LATCH coding pin *) item no. 00304910 1 each per solenoid valve
and per proximity switch
– Cable tie L x W = 140 x 3.6 mm item no. 00805141-01 5 - 6 units

SIPLACE 80 S-20 / S-23HM/ F4 / F4-6 / F5 2 Retrofitting Instructions for Ceramic Substrate Centering Unit (Optional)
04/2000 Issue 2.3 Retrofit Kit, Tools
43
– Mounting pedestal, self-adhesive item no. 00805103-01 2 - 3 units
- Screws to install the clamping element: 4 x countersunk screws M2*6 DIN965
- Pins to install the slide: 2 x parallel pins 3M5x10 DIN 6325
- Screws to install the slide: 2 x socket hex head cap screws M4 x 30 DIN 912
– where applicable, compression spring for holddown:
0.8 x 8.8 x 32 V2A item no. 00200342-01 2 units per conveyor
side
- where applicable, 2 countersunk screws M2.5 x 8 and 4 socket hex nuts M2.5
to fasten the green plastic rail (see Fig. 2.4.2).
NOTE:
The screws to mount the holddowns and the (substrate) guide rails are available from the earlier
disassembly.
7RROVDQG$X[LOLDU\7HVW(TXLSPHQW
– 1 set of Allen wrenches
– Cross-slotted screwdriver, size 1
– Punch 2.5 mm (to adjust the substrate size)
– 1 Diagonal-nosed wire cutters, small
– Crimp pliers (0.05 -0.12; 0.09 to 0.56)
– Adjustment plate L = approx. 50 cm
(edges parallel) or PCB as large as possible that meets the above conditions
– Feeler gauge 0.2 mm