Micron Maintenance Manual - 第79页

3 VACUUM FILTRATION UNITS 3.1 FILTER REPLACEMENT MAINTENANCE MANUAL MICRON 11/2017 79 9. Refit the carbon filter unit to the vacuum filtration unit. Note When refitting the carbon filter unit (5) to the base unit (7), en…

100%1 / 92
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
78 MAINTENANCE MANUAL MICRON 11/2017
7. To separate the pre-filter unit, (3) from the carbon filter unit (4), pull the pre-filter upwards us-
ing the pre-filter frame.
3
4
8. Replace the carbon\pre-filter as required and refit the pre-filter into the carbon filter unit.
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
MAINTENANCE MANUAL MICRON 11/2017 79
9. Refit the carbon filter unit to the vacuum filtration unit.
Note
When refitting the carbon filter unit (5) to the base unit (7), ensure that the rear of the carbon
filter unit is located beneath the filter securing the bracket (6).
5
6
7
10. Secure the carbon filter unit using the filter retaining clip.
11. Refit and secure the air duct to the carbon filter unit.
12. Refit the panel removed in Step 2.
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
80 MAINTENANCE MANUAL MICRON 11/2017
3.1.3 VF30 Vacuum Filtration Unit
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
To replace any of the filters in the vacuum filtration unit, carry out the following:
NOTE
Numbers in brackets e.g. (1), refer to the numbers in the graphics in the procedure.
1. Ensure the printer is switched OFF.
2. Remove the printer front panel.
3. Remove the air duct (1) from the carbon filter unit (3) using a screwdriver or box spanner to
release the securing clip (2).
1
3
2
4. Using a 6mm Allen key, remove the two securing screws (4), one on the left side and one on
the right side of the vacuum filtration unit.