Micron Maintenance Manual - 第89页

3 VACUUM FILTRATION UNITS 3.1 FILTER REPLACEMENT MAINTENANCE MANUAL MICRON 11/2017 89 To replace the filter in the vacuum filtration unit, carry out the following: NOTE Numbers in brackets e.g. (1), refer to the numbers …

100%1 / 92
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
88 MAINTENANCE MANUAL MICRON 11/2017
3.1.5 VF10 Vacuum Filtration Unit
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
1
2
3
4
Item Description Item Description
1 Printer Frame 3 Filter Case
2 Vacuum Tooling (If fitted) 2 VF10 Vacuum Filtration Unit
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
MAINTENANCE MANUAL MICRON 11/2017 89
To replace the filter in the vacuum filtration unit, carry out the following:
NOTE
Numbers in brackets e.g. (1), refer to the numbers in the graphics in the procedure.
1. Ensure the printer is switched OFF.
2. Remove the printer front panel.
3. Unscrew the filter case (6) from the vacuum filtration unit.
4. Replace the white HDPE foam filter (5) and refit the filter case (6) to the vacuum filtration unit.
5
6
5. Refit the panel removed in Step 2.
3 VACUUM FILTRATION UNITS
3.1 FILTER REPLACEMENT
90 MAINTENANCE MANUAL MICRON 11/2017