00198536-02_AI_Mixed-Mode_TX2iV1_TX2V2_de_en - 第107页
4 Appendix 4.1 Excerpts from the Service Manual Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 107 4.1.2.3 Replacing the COT-i-i central unit and lifting mechanics NOTIC…

4 Appendix
4.1 Excerpts from the Service Manual
106 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}77]
Fig.48: Cover
► Remove the screws fastening the
cover(1) on the trailing cable interface
and remove the cover.
► Unplug the electrical connections to the trailing interface. You may want to mark the position
to make clear assignment easier later on.
► Remove the six screws fastening the trailing interface and remove the interface from the
machine.
Installation
► Follow the removal instructions in reverse order for installation.
4.1.2.2 Installation Positions of COT Insert (Table Positions)
Fig.49: Installation positions
The inner and outer mounting positions de-
pend on the machine type.
The following installation positions apply to
the SIPLACE TX-Series:
1. COT insert at inner position:
SIPLACE TX1, TX2: location 2
SIPLACE TX2i: location 1 and 2
2. COT insert at outer position:
SIPLACE TX1, TX2: location 1
Fig.50: Example: inner position
Example:
1. COTi central unit mounted at inner
position

4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 107
4.1.2.3 Replacing the COT-i-i central unit and lifting mechanics
NOTICE
Working on the COT-i without complete removal of this
For some tasks on the COT-i, it may be enough to just pull the COT-i slightly out of the
machine. In this case, follow the procedure for replacement but observe the following
instructions:
► Remove the screws fastening the central unit and the lifting mechanics.
► You don't usually need to disconnect the cable. However, if the cable is too short,
unplug it.
► Slightly pull the COT-i out of the machine.
WARNING
Heavy machine parts
► Make sure that the COT-i does not fall out of the machine!
Overview
Fig.51: COT‑i parts
The COT-i for SIPLACE TX machines is split
into three separate parts (units) which are
mounted directly to the machine frame.
These parts are as follows:
1. Lifting mechanics left
2. Lifting mechanics right
3. COT-i central unit
The parts are directly fixed with eight screws
to the machine frame (four screws at the
COT-i central unit and two screws on each
of the lifting mechanics).
For the positions of the COT-i in the machine see 4.1.2.2 "Installation Positions of COT Insert
(Table Positions)" [}106].

4 Appendix
4.1 Excerpts from the Service Manual
108 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Parts, equipment and tools
●
Suitable lifting device (e.g. hand-operated crane)
●
Detailed circuit diagrams folder for SIPLACE TX V1-Series (up to no. 499) [DE+EN: 00197933-xx]
●
Detailed circuit diagrams folder for SIPLACE TX V1-Series (from no. 500) [DE+EN:00198274-xx]
●
Detailed circuit diagrams SIPLACE TX V2-Series [DE+EN: 00198460-xx]
Fig.52: COT‑i central unit assy [03117339‑xx]
(complete with FCU and tape cutter)
●
Select the required parts (also see
below):
– Lifting mechanics left assy
[03126040‑xx]
– Lifting mechanics right assy
[03126039‑xx]
– COT‑i central unit assy
[03117339‑xx]
(complete with FCU and tape cutter)
Removal of left and right lifting mechanics
NOTICE
Shown by example
The following procedure is shown by example of the left lifting mechanics. The procedure
for the right lifting mechanics the same. Relevant differences will be mentioned.
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}77]
Fig.53: Locking flap
The safety bolt(1) fixes the connection
between the pneumatic cylinder and the lift-
ing mechanics.
► Flip the safety catch down.
► Remove the safety bolt, to access the
connection.
CAUTION!
Pay attention to the position and
number of washers used.
.