4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 127
Equipment and tools
00353832-xx Allen key set
Set of screwdrivers
03079617-xx Depth measuring gauge (300mm)
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}77]
Fig.85: Nozzle changers
► Remove all magazines(1).
► Remove the four fixing screws(2).
► Unplug the nozzles changer from all electrical and pneumatic connections.
► Carefully lift the nozzle changer out of the machine.
Setting the installation height
► Set the correct installation height for the nozzle changer as follows:
DANGER
Strong permanent magnet fields
Observe the safety instructions in section 1.1.2 "Safety instructions for working with strong
magnetic fields" [}74].

4 Appendix
4.1 Excerpts from the Service Manual
128 Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019
Fig.86: Overview of measurement procedure
Overview of measurement procedure
1. Measuring scale
2. Top edge of the X axis upper linear
guide
3. Distance
4. Nozzle changer contact surface
NOTICE!
Alternatively, you can measure from
the top edge of the lower guide rail of
the gantry.
.
► During the following inside measure-
ment make sure that the tip of the
measuring scale does not touch the
magnetic strip as this might scratch it!
WARNING!
Strong magnetic forces
Place a suitable plastic plate between
the magnet and measuring scale, if re-
quired.
.
► Position the measuring scale(1) on the top edge of the X axis upper linear guide(2) and
measure the distance to the nozzle changer contact surface(4). Hold the measuring scale
vertically for this.
► Compare the measurement of the distance(3) with the target value (see table).
If needed, adjust the height by removing or adding NC shim plates.
Default configuration Mixed mode*
Default:
Measure from the upper edge of the
top linear guide
279 +/-0.2mm 282.65 +/-0.2mm
Alternatively:
Measure from the upper edge of the
bottom linear guide
118 +/-0.2mm 121.65 +/-0.2mm
NOTICE
* Mixed mode option
If applicable, observe the deviating measurements for the mixed mode option.
Mixed mode is only possible on machines of type SIPLACE TX2 V2.
Mixed mode is not possible on machines of type SIPLACE TX1 V2 and TX2i V2.
For more information, refer to the assembly instructions "Mixed Mode Op-
tion" [00198536‑xx].
CAUTION
Crash hazard!
Do not place too many shim plates underneath.

4 Appendix
4.1 Excerpts from the Service Manual
Assembly Instructions / Montageanleitung SIPLACE TX2i V1 SIPLACE TX2 V2 Option Mixed-Mode 01/2019 129
Fitting the nozzle changer
Fig.87: Jumper
► Set the jumper(1) on the nozzle
changer to 2-3.
► Fix the nozzle changer onto the two holders with four screws.
► Calibrate the position of the nozzle changer.
4.1.3.5 Replacing the nozzle station
Parts
Fig.88: Nozzle station
Machine types Item no. Designation
1 SIPLACE TX1/TX2 V2 03090348-xx Nozzle station CPx complete / X4iS, XS
2 SIPLACE TX2i V2 03135777-xx Nozzle station assembly
All 03039514-xx Shim plates: support for nozzle reject
device
Equipment and tools
00353832-xx Allen key set
03079617-xx Depth measuring gauge (300mm)