ReleaseNote_ALL_for_V30VGOSALL.pdf - 第127页
YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. YAMAHAMOTORCO.,LTD. IMOperations IMOperations IMOperations IMOperations ReleaseNote(English) 2011/2/1 Ver Ver Ver Ver Rev Rev Rev Rev N um Num Num …

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.21 1.000 TT4807
TT4807TT4807
TT4807 14
1414
14 Bug AllMachine Operator
Whenthefollowingprocedureswereexecuted,therewasabugthatanoperatorlevel
couldn’tbechanged.
1.Startauto-running.
2.Tap[Operator]andselectanyoperator.
3.Theoperatorlevelcouldn’tbechangedbecause[OK]buttonisgrayedout.
Itisfixed.
3.21 1.000 TT5000
TT5000TT5000
TT5000 15
1515
15 Bug Mounter Tray
Whenallofthefollowingconditionwassatisfied,therewasabugthatthemachine
becamesleep.
1.[Board]-[Board]-[RetrySequence]-[Block]is“Block”.
2.[Parts]-[Option]-[Parts.GroupNo.]offeederpartsisset.
3.WhenpartsispickedfromATS,blockretryisexecuted.
4.Atthetimeoftheblockretry,thepreceding2and3partsarepickedinthesame
group.
Itisfixed.
3.21 1.000 TT4998
TT4998TT4998
TT4998 16
1616
16 Bug Mounter History
Whenasplicingknotisdetected,therewasabugthat[Unitlog]-[FeederID]-[No
PartsErrorCounter]wasnotcounted.
Itisfixed.
3.21 1.000 TT4999
TT4999TT4999
TT4999 17
1717
17 Bug Mounter History
Whenallofthefollowingconditionweresatisfied,therewasabugthat"Currentdata"
wasnotaddedto"Recentdata"whenthehistorywasoutput.
1.On[Setup]–[SoftwareSetting]–[History],
1)Anypathisenteredin[Unitlogsetting]–[Parts]–[ServerPath].
2)[History]–[Thehistoryisoutputatspecifiedtime]is“chekedstate”.
Itisfixed.
3.21 1.000 TT5202
TT5202TT5202
TT5202 18
1818
18 Bug YG12Series Optimization
Whenoptimizationwasexecuted,unnecessary[Ea17735:ReelLayoutError]might
occur.
*Inordertoavoidthiserror,input"752.00"(designvalue)to[ReelHolderWidth]whose
[Setting]-[SpecificationInformation]-[PlateSpecification]-[SetNo.]is"1".
Thisproblemcausedbyincorrectsettingthatreelholderwidthnotedaboveissetto
"0"atthetimeofnewinstallation.
Itisfixed.
3.21 1.000 TT5279
TT5279TT5279
TT5279 19
1919
19 Bug
YS24(X)SL/
DL
Unit
Altoughthesettingoftheconveyordirectionwas[L->R],therewasabugthatthe
imageofthefollowingbuttonwas[R->L].
1.[Unit]-[Conveyor]-[ConveyIn]button
2.[Unit]-[Conveyor]-[ConveyOut]button
Itisfixed.
3.21 1.000 TT5210
TT5210TT5210
TT5210 20
2020
20 Bug YS24Series Teach
Whenallofthefollowingconditionsweresatisfied,therewasabugthatincorrectvalue
wasinputtomountingcoordinatesbyteaching.
1.[Machine]–[InstallationSetting]–[BaseMACS]is"Use".
2.Fiducialalignmentisenabledinaselectedboarddata.
3.[Teach]–[Setting]–[FiducialCorrection]issetto"checkedstate".
Itisfixed.
3.21 1.000 TT5293
TT5293TT5293
TT5293 21
2121
21 Bug
YS24X
Series
Tray
Whenallofthefollowingconditionsweresatisfied,therewasacasethat[Ea29011:
WARNINGPICKPOSITIONFORTRAY]occurredbymistakeatthetimeofdatacheck.
1.Traypartsisused.
2.Traypartsarearrangedatveryclosetothelimitofthepaletteinnercircumference
thatcanbepicked.
Itisfixed.
3.21 1.000 TT5068
TT5068TT5068
TT5068 22
2222
22 Bug
YS24XSL/D
L
Teach
Whenanythefollowingprocedurewereexecutedtherewasabugthat[Es00013:2nd
LIMITOVER]occurredcontinuouslyinspiteofclosingit
1.Movetheaxisoutofthesoftlimit.
2.SelectATSpartsandtap[Parts]-[Tray]-[PitchTch]-[MovePitch].
3.[Es00013]occurs.(Itoccurscontinuouslyuntiltheaxisismovedoutofthesoft
limit.)
Itisfixed.
3.21 1.000 TT5116
TT5116TT5116
TT5116 23
2323
23 Bug
YSSeries
Mounter
System
Backup
Whenthefollowingprocedurewasexecuted,therewasabugthatthe"Mounter
applicationabnormalend"occurred.
1.On[Setup]-[SoftwareSetting]-[Basic]-[SystemBackup],
1)[Fixafolder]is“chekedstate”.
2)Thenumericalvalueisseton[FolderName].
Itisfixed.
3.21 1.000 TT5313
TT5313TT5313
TT5313 24
2424
24 Bug
YSSeries
Mounter
Database
Whenthefollowingprocedureswereexecuted,therewasabugthatthe"Mounter
Applicationabnormalend"occurred.
1.[Setup]–[Database]–[Thetimingtosetfromdatabaseall(partsandmark)]is
“AfterBoardReadingAndAutoRunStarting”or“AfterBoardReadingOnly”.
2.Thereisaparts(mark)informationwhichisthetargettobesetfromthedatabase.
3.Thisinformationisdifferentfromthatinthedatabase.
4.Tap[Setup]–[Board]–[Select]button.
Itisfixed.
3.21 1.000 TT5313
TT5313TT5313
TT5313 25
2525
25 Bug
YSSeries
Mounter
Database
Whenthefollowingprocedureswereexecuted,therewasabugthatthe"Mounter
Applicationabnormalend"occurred.
1.[Setup]–[Database]–[Thetimingtosetfromdatabaseall(partsandmark)]is“After
BoardReadingAndAutoRunStarting”.
2.Therewasaparts(mark)informationwhichisthetargettobesetfromthedatabase.
3.Thisinformationisdifferentfromthatinthedatabase.
4.Startauto-running.
Itisfixed.
MDOC-VG30-00001 126/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.21 1.000 TT5058
TT5058TT5058
TT5058 26
2626
26 Bug
YSSeries
Mounter
ConveyorOut
Whenallofthefollowingconditionsweresatisfied,therewasabugthatthecarried-out
boardwasnotcarriedouttothedownstreammachine,andstoppedattheexitposition.
1.[VmSpec]–[InstallationSetting]–[StriedboardBuffering]is“Enable”.
2.[Ea31:PICKUPERROR]etc.occurswhiletheboardiscarriedoutfromthemachine
tothewaitingpositioninthedownstreammachine.
Itisfixed.
3.21 1.000 TT5152
TT5152TT5152
TT5152 27
2727
27 Bug
YSSeries
Mounter
ConveyorOut
TheUROUTsignalwasturnedoffthoughthecarried-outboardwascarried,
therewasabugthatthestateofthemachinewas"WAITSTOP".
Itisfixed.
3.21 1.000 TT5212
TT5212TT5212
TT5212 28
2828
28 Bug
YSSeries
Mounter
ConveyorOut
1.Theboardwascarriedto"boardfixingposition".
2.Whenthe"pickuperror"etcoccur,thestateofthemachinewaschangedto"WAIT
STOP".
Itisfixed.
3.21 1.000 TT5179
TT5179TT5179
TT5179 29
2929
29 Bug
YSSeries
Mounter,
YG12Series
Tray
Whentraypartsarrangedinazigzaglineareused,therewasabugthattraypartscould
notberefilledbecausethecheckboxon[Setup]-[TrayCnt]-[ATSSupp.]screen
wasnotdisplayed.
Itisfixed.
3.21 1.000 TT5112
TT5112TT5112
TT5112 30
3030
30 Bug Printer Cleaning
Therewerethefollowingbugswhencleaningfeedbackwasexecuted.
1.Theinspectionwasnotexecuted,although[Inspection]-[Inspection]-[AfterAuto
Cleaning]-[Inspection]was“Use”.
2.When“ControlledintheBoard”cleaningwasenabled,cleaningwasexecutedin
anotherwayoratanothertimingbymistakebecausethecleaningcounterwasnot
cleared.
Itisfixed.
3.21 1.000 TT4915
TT4915TT4915
TT4915 31
3131
31 Bug Printer History
Therewerethebugsin[MIS]asfollows.
1.Onthe[MIS]-[BoardLog]tab.
1)Thevalueof[DownstreamStandbyCT]wasaddedtothatof[TransferCT]by
mistake.
2)Thevalueof[BoardRemove]wasnotaddedevenifaboardistakenoutwhenthe
solder-printinspectionresultwasNG.
3)Thevalueof[UpstreamStandbyCT]wasaddedonlywhenaboardwasexistedon
theexitconveyor.
4)Thevalueof[FeedbackPrint]and[FeedbackCleaning]werenotadded.
2.Insteadofthemeanvalue,themaximumvaluewasdisplayedonthe[MIS]-[Program
Log]-[PrintCTAVE].
Itisfixed.
3.21 1.000 TT5061
TT5061TT5061
TT5061 32
3232
32 Bug Optimizer Feeder
Whenaboarddatawasoptimized,somefeedersmightbeassignedfromtheendsofthe
feederplatealthoughtherewasenoughnon-occupiedfeederspace.
Itisfixed.
3.21 1.000 TT5082
TT5082TT5082
TT5082 33
3333
33 Bug Optimizer Optimization
Whenanyofthefollowingconditionsweresatisfied,therewasabugthatanoptimized
boarddatawascreatedalthoughtheoptimizationfailed.
1.Loadingaboarddatafails.(Ex.[Ea663:FileError])
2.Nozzleinterferencecheckfails.(Ex.[Ea16159:Failureinpartsgroupnumbering])
Itisfixedthatan
optimizedboard
dataisnot
createdafterthe
optimizationfails.
3.21 1.000 TT5134
TT5134TT5134
TT5134 34
3434
34 Bug Optimizer Optimization
Whenallofthefollowingconditionsweresatisfied,therewasabugthatpallet
interferenceerror,[Ea17659:Thepalletsupplyingpartsinterfereswiththedumppallet.]
etc.,occurredalthoughtherewasno“RecoveryPallet”inthemachine.
1.[MachineProperty]-[MachineInformation]-[]InstallationSetting]-[Option]-
[RecoveryPallet]is“NONE”.
2.Thevalueof[MachineProperty]-[MachineData]-[TrayChanger]-[Position]-
[RecoveryPalletNumber]isbetweenthefollowings.
1)Thevalueof[Parts]–[Tray]–[PalletNo.Start]
2)Thevalueof[Parts]–[Tray]–[PalletNo.Last]
Itisfixed.
3.21 1.001 KHn312
KHn312KHn312
KHn312 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug AllMachine Servo
Whenanyofthefollowingconditionsweresatisfied,therewasabugthat[Es00025:
PHASELOSS]occurredbymistake.
1.Whileanyoftheaxesaremoving(e.g.duringwarmingup),[EMERGENCYSTOP]
buttonispressed.
2.Whileanyoftheaxesaremoving(e.g.duringwarmingup),[EsXXXXX:SERVO
ERROR]occurs.Especiallyatthefollowingaxes,itoccurredwithhighfrequency.
1)SCaxis(YS12,YG12,YS12P,YS24)
2)AZaxis(ThemachinewithsATS)
3)SZaxis(YSP)
4)DYandDZaxes(ThemachinewithdYTF)
Afterclearing[Es00025:PHASELOSS]andpressing[READY]button,if[Es00025]
appearsagain,thismeansthatphaselossisactuallydetected.Otherwise,itisafalse
detection,sopleaserestartthemachine.
Itisfixed.
3.22 1.000 TT5453
TT5453TT5453
TT5453 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug AllMachine
Application
exit
Therewasabugthatmightcausethemachineapplicationabnormalendwhenvarious
errorsoccurredoneafteranother.
Itisfixed.
3.22 1.000 TT5372
TT5372TT5372
TT5372 2
22
2 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Editor
Whenthefollowingprocedureswereexecuted,therewasabugthatacombinedboard
datacannotbesaved.
1.ThemounterapplicationwhoseversionisV3.21STDR1.000orlaterisused.
2.Click[Editor].
3.Selectacombinedboarddataon[File]-[OpenBoardData].
4.Although[File]-[SaveBoardData]isselected,thecombinedboarddatacannotbe
saved.
Itisfixed.
MDOC-VG30-00001 127/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.22 1.000 TT5374
TT5374TT5374
TT5374 3
33
3 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Editor
Whenthefollowingprocedureswereexecuted,therewasabugthatacombinedboard
datawassavedwithouttheoverwriteconfirmation.
1.ThemounterapplicationwhoseversionisV3.21STDR1.000orlaterisused.
2.Click[Editor].
3.Loadacombinedboarddatafrom[File]-[OpenBoardDatainthisEditor].
4.On[Boarddatasave]window,select[SaveBoardDataAs...],theninputthe
combinedboardnamewhichalreadyexists.
5.Click[Save]button.
Itisfixedsothat
[Ea12046:FILE
OVERWRITE]will
bedisplayed.
3.22 1.000 TT5400
TT5400TT5400
TT5400 4
44
4 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL Optimization
Whenallofthefollowingconditionsweresatisfied,therewasabugthatoptimization
succeededbymistakealthoughitshouldfailand[Ea131:BOARDDATAERROR]should
occur.Thisbugmightcausemismountingbyusingtheboarddata.
1.YS24(X)DLexistsintheline.
2.Boarddataformatis"YGX(Combined)".
3.Thereisapartsdatawhichisin[Board]-[Mount]-[P.No.]butisnotused.
Itisfixed.
3.22 1.000 TT5387
TT5387TT5387
TT5387 5
55
5 CriticalBug
CriticalBugCriticalBug
CriticalBug YS24(X)DL CycleStop
Whenthefollowingprocedureswereexecuted,therewasabugthataboardcarriedout
withoutcompletingthemounting.
1.Conditions
1)[Board]-[MountMode]is"EachLanes".
2)[Setup]-[CycleStop]is"ON".
2.Procedures
1)Whenboardsexistinbothconveyorlanes,tap[CycleStop]button.
2)Press[RESET]button.
3)Restartauto-running.
Itisfixed.
3.22 1.000
TT5267
TT5267TT5267
TT5267
TT5376
TT5376TT5376
TT5376
TT5433
TT5433TT5433
TT5433
6
66
6 CriticalBug
CriticalBugCriticalBug
CriticalBug Printer Auto-running
Whenthefollowingprocedureswereexecuted,theprintermightoccasionallybecome
sleep.
1.Press[EMERGENCYSTOP]buttonduringauto-running.
2.Press[RUN]buttonontheoperationpanel.
Itisfixed.
3.22 1.000 TT5104
TT5104TT5104
TT5104 7
77
7 CriticalBug
CriticalBugCriticalBug
CriticalBug Printer Auto-running
Whenthefollowinginterlockerrorsoccurred,forexample,theprinterapplicationmight
becomesleep.
1.[Ea8050:FLAPUPINTERLOCK]
2.[Ea8055:CLEANERFREEINTERLOCK]
3.[Ea8059:UNABLETOMOVEAXISWITHABOARDONTHECONVEYOR]
Theotherinterlockerrorsarethesame.
Itisfixed.
3.22 1.000 TM2284
TM2284TM2284
TM2284 8
88
8 Add Mounter Feeder
ThefollowingFeedertypeshavebeensupported.
1.88mmTape
2.104mmTape
3.120mmTape
4.136mmTape
5.152mmTape
6.168mmTape
7.184mmTape
8.200mmTape
Itismodified.
3.22 1.000 TM2413
TM2413TM2413
TM2413 9
99
9 Add Printer Boarddata
When[Print]-[Basics]-[MaskSize]is"750[mm]*650[mm]"inaboarddata,the
maximumvalueof[BoardSizeY(mm)]hasbeenchangedasfollows.
Beforethechange:250mm
Afterthechange:330mm
Itismodified.
3.22 1.000 TP1901
TP1901TP1901
TP1901 10
1010
10 Add Optimizer Fixedboard
Ithasbeenmodifiedsothattheoptimizercancreatetheresultthatisbetterfor
parallellanesmountingwhenitisexecutedwithparallellanesmountingandwiththe
settingwhichusefixedboardin[Setoptimizationparameter]–[Detail].
Itismodified.
3.22 1.000 TT5296
TT5296TT5296
TT5296 11
1111
11 Change AllMachine GUI
When"FileFormat"or"Lanenumber"on[Setup]-[BoardExplorer]ischanged,ithas
beenchangedsothatthefileformatandthelanenumberonthefollowingscreenwon't
changedependingonit.
1.[Setup]-[Board]
2.[Save]
Therefore,itisabletoselectorsaveanintendedboarddata.
Itismodified.
3.22 1.000 TP1740
TP1740TP1740
TP1740 12
1212
12 Change Mounter GUI
Theusageof[ServerPath:]on[Setup]-[SoftwareSetting]-[Network]-[Network
setting]hasbeenchangedasbelow.
Before:boarddata,POSinformation,RetryinformationandHistory
After:boarddatalocation
Therefore,the[Network]buttonsonthefollowingscreensweredeleted.
WhenyouchoseafolderintheNetwork,selectitfrom[Folder]button.
1.[Parts]-[PartsAdj]-[RandomBall]-[ReadPOS]
2.[MIS]-[SaveLog]
3.[Unitlog]-[SaveLog]
4.[Monitor]-[Retry]-[Save]
Itismodified.
MDOC-VG30-00001 128/151