3.05 1.000 TP0536
TP0536TP0536
TP0536 11
1111
11 Change Mounter Database
Itwasimprovedthatthetimefordisplayingfollowingdatabaselistwasshortenedto
about1/3.
1.[Parts]-[Basic]-[Database]
2.[Mark]-[Basic]-[Database]
Itismodified.
3.05 1.000 TM0739
TM0739TM0739
TM0739 12
1212
12 Change YG300 Dump
ThestoppositionoftheheadafterpartsdumpingwaschangedfromDiscardPointto
WaitPoint.WhenaheadwasonDiscardPoint,afeederandaheadinterfereandthe
feederexchangeworkbecamedifficult.
Itismodified.
3.05 1.000 TT3212
TT3212TT3212
TT3212 13
1313
13 Bug Mounter
Machine
Setting
Therewasabugthatitwasimpossibletoinputlargevaluethan"999"in[Setting]-
[SpecificationInformation]-[NozzleSpecification]-[NozzleData]-[VacuumSpec].
Itisfixedthatit
ispossibleto
inputthevalue
upto"9999".
3.05 1.000 TT3269
TT3269TT3269
TT3269 14
1414
14 Bug Mounter
Machine
Setting
Therewasabugthatfollowinggarbageitemsweredisplayed.
1.[Setting]-[MachineInformation]-[OptionSetting]-[Basic]-[PickPos
Correction]
2.[Setting]-[MachineInformation]-[InstallationSetting]-[Option]-[PickPos
Correction]
Itisfixed.
3.05 1.000 TT3008
TT3008TT3008
TT3008 15
1515
15 Bug Mounter ErrorMessage
Therewasabugthat[FeederSetPos.]wasalwaysdisplayedas"-1"on
[Ea2889:EMERGENCYSTOPFUNCTIONDURINGPICK]message.
Itisfixed.
3.05 1.000 TT2938
TT2938TT2938
TT2938 16
1616
16 Bug Mounter Teach
Therewasabugthat[1Pixel]and[10Pixel]buttonwerenotexclusiveon[Parts]-
[Tray]-[PitchTch]-[Cursor].
Itismodifiedthat
[1Pixel]and[10
Pixel]buttonare
exclusive.
3.05 1.000 TT3064
TT3064TT3064
TT3064 17
1717
17 Bug Mounter Teach
Whenthefollowingprocedureswereexecuted,therewasabugthatthevalueofthe
axiscoordinate[X(mm)]or[Y(mm)]inthe[AxisMovement]screenisnotupdated.
1.Usetrayparts
2.Displaythe[TeachingaPitch]screenbyclickingthe[Parts]-[Teach]-[PitchTch]
button,andclosethescreen.
Itisfixed.
3.05 1.000 TT2938
TT2938TT2938
TT2938 18
1818
18 Bug Mounter Teach
Therewasabugthattheunitofaxismovementwas1pixel,evenif[10Pixel]button
wasclickedon[Parts]-[Tray]-[PitchTch]-[Cursor]tabscreen.
Itismodified.
3.05 1.000 TT3262
TT3262TT3262
TT3262 19
1919
19 Bug Mounter Datacheck
Whentheboarddatathatsatisfiedallthefollowingconditionswasselected,therewasa
bugthatthe"Machinecontrolstopped(Ea12051)"andabnormalprogramtermination
occurred
1.Theboarddatausesthe4-pointficucialfunction
2.Thefirstblockisskippedinthemulti-blockboarddata.
Itisfixed.
3.05 1.000 TT3295
TT3295TT3295
TT3295 20
2020
20 Bug Mounter TapeCutter
Whenthefollowingprocedureswereexecuted,therewasabugthatthetapecutters
couldnotworkinproduction,andthepickuperrorcouldbecausedastheresult.
1.Selecttheboarddataspecifiedaspassmoderunning.
2.Selecttheotherboarddatanotspecifiedaspassmoderunning,andstartauto-
running.
Itisfixed.
3.05 1.000 TT3296
TT3296TT3296
TT3296 21
2121
21 Bug Mounter Tray
Whenthefollowingprocedureswereexecutedinusingthemachinethatequipped
__sATS__,therewasabugthattheresetwasneededforrestartingauto-running,
because"AutotraychangerPalletseterror(Ea20968)"wasdisplayed.
1.StartproductionusingtheboarddataincludingthetraypartssetatthePalletNo.1-
3.
2.AfterusingthetraypartssetatthePalletNo.1-2andthenusingthetraypartsset
atthePalletNo.3,"Auto.traychangerComponentemptystop(Ea29089)"isdisplayed.
3.OpenthemagazinedoorandrefillthenewpartsatthePalletNo.1-2bypushingthe
indicatorbuttons.
4.RemovethepalletsetatthePalletNo.3fromthemagazineandrestartauto-
runnning.
5.Ea29068isdisplayed,becausethepallet(PalletNo.3)thatdoesnotexistinthe
magazinetriestobepulledout.
Itisfixed.
3.05 1.000 TT2220
TT2220TT2220
TT2220 22
2222
22 Bug Mounter Trace
Whenthefollowingprocedureswereexecuted,thetracepositionwasnotcorrectedby
FiducialCorrection.
1.Theboarddatausedonlylocalfiducial.
2.[Board]-[Mount]-[Teach]-[Trace].
Itisfixed.
3.05 1.000 TT2899
TT2899TT2899
TT2899 23
2323
23 Bug Mounter Monitor
Therewasabugthatincorrectvalueof[VisionRate]and[PickupRate]in[Monitor]-
[Main]screenweredisplayed,whenthefollowingprocedurewasexecuted.
1.[SoftwareSetting]-[History]-[MISbyBoardsetting]-[EnableMISbyBoard]is
checked"ON".
2."Auto-Running"isexecuteduntilVisionRateandPickupRatearecalculated.After
then,stopthemachine.
3.Reloadtheboarddata.
Itisfixed.
MDOC-VG30-00001 87/151
YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.05 1.000 TT3060
TT3060TT3060
TT3060 24
2424
24 Bug Mounter CleaningBlow
Therewasabugthat[Verificationmanualexchangenozzles]wasrequested,evenifit
wasautonozzlechangehead,when[Unit]-[Head]-[CleaningBlow]wasexecuted.
Itisfixed.
3.05 1.000 TT3334
TT3334TT3334
TT3334 25
2525
25 Bug Mounter CleaningBlow
Whenthefollowingprocedureswereexecuted,therewasabugthatCleaning-Blowwas
executed,evenif[Cleaning-Blow]wassetto[NotUse]in[Machine]-[Specification
Information]-[MountNozzleSpecification]-[NozzleData].
1.Click[Unit]-[Head]-[CleaningBlow]button.
2.Select[Executefornozzleonlyonthehead].
Itisfixed.
3.05 1.000 TT2902
TT2902TT2902
TT2902 26
2626
26 Bug Mounter Conveyout
Whenthefollowingprocedureswereexecuted,therewasabugthattheerrormessage
"Ea85:BOARDTRANSFERERROR"wasdisplayed.
1.Starttransferringthelastboardofscheduledproductiontothemountposition.
2.Stopauto-runningbySTOP,emergencystop,orsomekindoferror,justbeforeboard
fixation.
3.Restartauto-running.
Itisfixed.
3.05 1.000 TT2848
TT2848TT2848
TT2848 27
2727
27 Bug Mounter Partadj
Therewasabugthat[PartsAdjust]-[NozzleType]comboboxbecameemptywhen
the"Ea31:PICKUPERROR"occurred.
Itisfixed.
3.05 1.000 TT3053
TT3053TT3053
TT3053 28
2828
28 Bug Mounter Partadj
Whenthefollowingprocedureswereexecuted,therewasabugthat
[Ea2907:COMPONENTDATAERROR]occurredandthepartscouldnotbepickedup.
1.Usetrayparts.
2.[Parts]-[Pick]-[SetNo.]is"0".
3.Click[PartsAdj]-[PickUp]-[Pickupfromthetray].
Itisfixed.
3.05 1.000 TT3052
TT3052TT3052
TT3052 29
2929
29 Bug YSSeries MIS
Onthefollowingconditions,therewasabugthatthePitchIndexofboarddatawas
outputto[Unitlog]-[Parts]-[PitchIndex].
1.UsetheSSFeeder.
2.[Setting]-[MachineInformation]-[OptionSetting]-[Referenceoffeederpitch]is
setto[Feedersetup].
Itisfixedthat
thePitchIndex
settoSSfeeder
isoutput.
3.05 1.000 TT3153
TT3153TT3153
TT3153 30
3030
30 Bug
YG12,YS12,Y
S88,YS100
MIS
Onthefollowingconditions,therewasabugthat"1900/01/0100:00:00"wasdisplayed
on"StartTime"in[MIS]-[Board].
1."Board"-"PrecedePick"issetto"Use".
2.Putaboardatthewaitpositionandstartauto-running.
Itisfixed.
3.05 1.000 TT1794
TT1794TT1794
TT1794 31
3131
31 Bug YG300 Teach
Whenthefollowingprocedureswereexecuted,therewasabugthatillegalerrorof
"Es00305:SoftlimitOver"occurred.
1.Theparameterof[Board]-[Offset]-[X]isover+200orunder-200.
2.Selectthelineof[Board]-[Offset]-[Type]of[BoardOffset],andexecute[Teach]
-[Trace].
Itisfixed.
3.05 1.000 TT2580
TT2580TT2580
TT2580 32
3232
32 Bug YG300 Conveyout
Whenslitboardswereused,therewasabugthatmachinesometimeslosttheboardon
theconveyorafterunclampingtheboard.
Ea7302(BOARDTRANSFERERROR)occurredafternextstagetransportation,because
thelostboardwasnotmanaged.
Toremovethe
lostboardsurely,
itismodifiedthat
itdisplay
Ea7321(BOARD
TRANSFER
ERROR)before
nextstage
transportation.
Andauto-running
isnotpermitted
untilmachine
reset.
3.05 1.000 TT3211
TT3211TT3211
TT3211 33
3333
33 Bug YS100
Machine
Setting
Therewasabugthatitwasimpossibletoedit[Setting]-[SpecificationInformation]-
[NozzleSpecification]-[NozzleData]-[VacuumSpec].
Itisfixed.
3.05 1.000 TT3338
TT3338TT3338
TT3338 34
3434
34 Bug YS12,YG12 Servo
Whenthefollowingprocedureswereexecuted,therewasabugthatthemachineslept.
1.Theemergencystop.
2.Solvethecauseoftheemergencystop.
3.PresstheREADYbuttonoftheoperationpanel.
4.PresstheRESETbuttonoftheoperationpanelin100msaftertheREADYbuttonis
pushed.
Itisfixed.
3.05 2.000 TM0638
TM0638TM0638
TM0638 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug YSSeries MIS
Thevalueofthefollowinghistoryscreenswasnotdisplayeddefinitelyunderthe
conditionofusingtwinpushup.
1.[MIS]-[Boardlog]
2.[MIS]-[Programlog]
Itisfixed.
MDOC-VG30-00001 88/151
YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.05 2.000
KHN-
KHN-KHN-
KHN-
58D9.02
58D9.0258D9.02
58D9.02
3
33
3
2
22
2 Add Mounter Conveyout
Thenewfunctionwasaddedthatthemotorbrakeworkedtoimprovetheretentivityof
theboardafterexchangingtheconveyorwidth.
Itismodified.
Itisnotabnormal
thoughthebrake
soundmightbe
generatedin
exchangingthe
conveyorwidth.
3.05 2.000 TS0595
TS0595TS0595
TS0595 3
33
3 Add YS12 Optimization
Onallthefollowingconditions,thenewoptimizeralgorithmwasaddedthatthepicktime
ofthemachinecouldbeshortenedbyallocatingfeederspreferentiallyononefeeder
plate.
1.Feederplateswith24feederpositionsareequipped
2.Allfeedersusedintheboarddatacanbeallocatedononefeederplate
Itismodified.
3.05 2.000 UD1127
UD1127UD1127
UD1127 4
44
4 Change Mounter Editor
Thelabelnameof[Setoptimizationparameters]-[BasicCondition]-[Level]radio
buttonwaschangedasfollows.
1.[Detail]->[BestOptimizationResult]
2.[Normal]->[Standard]
3.[Simple]->[ShortCalculationTime]
Itismodified.
3.05 2.000 TT3396
TT3396TT3396
TT3396 5
55
5 Bug Mounter GUI
Inthefollowinglanguages,somealgorithmsentencesdisplayedat[Parts]-[Shape]-
[Algorithm]-[VisionAlgorithmSelect]hadunnecessarylinefeed.
1.Japanese
2.Chinese
3.Korean
Itisfixed.
3.05 2.000 TT1429
TT1429TT1429
TT1429 6
66
6 Bug Mounter Editor
Therewasabugthatthewidthofthegridrowoffollowingscreenswasreturnedto
standardwidthwheneverthescreenwasdisplayedthoughthewidthwaschanged,
becausethewidthwasnotpreserved.
1.[Editor]-[mainview]
2.[Editor]-[detailview]
Itisfixed.
3.05 2.000 TT3230
TT3230TT3230
TT3230 7
77
7 Bug Mounter ErrorMessage
Therewasabugthatthebuzzerkeptringinguntilclickinga[BUZZEROFF]buttonin
theerrordialog,whenthefollowingerrorsoccurredduringmachinestopping.Itis
correctthatthebuzzerringsonlyonce.
1.Ea803:INTERLOCK"FRONT-FEEDERSENSOR1"
2.Ea807:INTERLOCK"REAR-FEEDERSENSOR1"
3.Ea814:INTERLOCK"FRONT-FEEDERSENSOR2"
4.Ea815:INTERLOCK"REAR-FEEDERSENSOR2"
5.Ea29501:INTERLOCK"FRONT-FEEDERSENSOR1_2"
6.Ea29502:INTERLOCK"REAR-FEEDERSENSOR1_2"
7.Ea29503:INTERLOCK"FRONT-FEEDERSENSOR2_2"
8.Ea29504:INTERLOCK"REAR-FEEDERSENSOR2_2"
9.Ea29523:QUICKSTOPACTIVE
10.Ea29524:QUICKSTOPACTIVE
11.Ea29525:QUICKSTOPACTIVE
12.Ea29526:QUICKSTOPACTIVE
Itisfixed.
3.05 2.000 TT3381
TT3381TT3381
TT3381 8
88
8 Bug Mounter
Sideview
camera
Whenthefollowingprocedureswereexecuted,therewasabugthattheerrormessage
"Ea942:Sideviewcamera,Nozzlerecognitionerror"wasdisplayed.
1.Executepartsadjustmentforthepartswhose[Parts]-[Shape]-[NozzleTouch
PointOffset(mm)]parameterislargerthan0.5mm
2.Click[Setup]-[MeasureNozzles]button
3.Startauto-running
Itisfixed.
3.05 2.000 TT3328
TT3328TT3328
TT3328 9
99
9 Bug Mounter
Alternative
parts
Therewasabugthatthefeederview(orpalletview)ofalternativepartswasnot
displayedin[Monitor]-[Production]-[Statusarea]whentheboarddataincludingthe
partswith3ormorealternativeloopwasused.
Itisfixed.
3.05 2.000 TT3428
TT3428TT3428
TT3428 10
1010
10 Bug Mounter Partadj
Whenthefollowingprocedureswereexecuted,therewasabugthataninternalerror
occurred.
1.Errorstopby"PICKUPERROR","COMPONENTDETECTIONERROR"andsoon
2.Clickthe[ERRORCLEAR]buttonontheerrordialog
3.Selectthepartsthatarenotobjectsoftheerroronthepartsinformationscreen
4.Clickthe[Parts]-[Adjust]button
Itisfixed.
3.05 2.000 TT3381
TT3381TT3381
TT3381 11
1111
11 Bug YS12,YG12
Sideview
camera
Whenthefollowingprocedureswereexecuted,therewasabugthattheerrormessage
"Ea942:Sideviewcamera,Nozzlerecognitionerror"wasdisplayed.
1.Executepartsadjustmentforthepartswhose[Parts]-[Shape]-[BodySizeZ
(mm)]parameterislargerthan0.5mm
2.Click[Setup]-[MeasureNozzles]button
3.Startauto-running
Itisfixed.
3.05 2.000
Vis0809
Vis0809Vis0809
Vis0809
004
004004
004
12
1212
12 Bug YS12,YG12
Sideview
camera
Whenthe[MeasureNozzles]buttonon[Setup]screenwasclicked,therewasthe
possibilitythattheerrormessage"Ea7529:Itfailedtomeasurethenozzleshape
(details:165)."wasdisplayed.
Itisfixed.
MDOC-VG30-00001 89/151