3.06 1.001 TT3705
TT3705TT3705
TT3705 27
2727
27 Bug YS100、YS88 Partadj
Whenthefollowingprocedureswereexecuted,themounterapplicationabnormalend
mightoccurr.
1.Themachinehasthecoplanaritychecker.
2.[Machine]-[InstallationSetting]-[Co-PlanarityChecker]isnot"None".
3.[Board]-[Board]-[3DCo-Planarity]is"Use"
4.CreatethepartsinformationtothePartsNo.1asfollows.
1)[Parts]-[Shape]-[Algorithm]isnot"Normal".
2)[Parts]-[Shape]-[EditMode]is"Details".
5.CreatethepartsinformationtothePartsNo.2orlaterasfollows.
1)[Parts]-[Shape]-[AlignmentType]isthetypethatcanusethecoplanarity
check.(SOP,QFP,BGAetc.)
2)[Parts]-[Vision]-[3DCo-PlanarityThreshold(um)]isnot"NotUse"
6.Executeeitherofthefollowings.
1)Selectthepartsinformationthatsetby5.,andclick[Parts]-[PartsAdj]-[3DCo-
Planarity].
2)WhenPICKUPERROR(Ea31)etc.occursinthepartsof5.inauto-running,click
[PartsAdj]-[3DCo-Planarity]onthedisplayederrordialog.
Itisfixed.
3.06 1.001 TT3631
TT3631TT3631
TT3631 28
2828
28 Bug YS12,YG12 Database
Whenthefollowingconditionwassatisfied,therewasabugthat"Ea2742:Failedto
readMarkData"occurredwhentheboarddatawasloadedandthatthemachinewas
notabletostartauto-running.
1.[Setup]-[Database]-[databaseutility]-[Databasepath]is\Common\D_Base
underthefolderthatP-Toolisinstalled.
Itisfixed.
Boarddatais
possibletoread
innormally,
whendatabase
pathisspecified
"\Common\D_Ba
se"underthe
folderthatP-
Toolisinstalled.
3.06 1.001 TT3425
TT3425TT3425
TT3425 29
2929
29 Bug Editor Randomball
Whenallthefollowingconditionsweresatisfied,therewasabugthattheboarddata
whichhavethepartsdatafailedintherecognitionofrandomballpartswasgenerated.
1.Makethepartsinformationasfollows
1)[Parts]-[Basic]-[AlignmentGroup]is[Ball]
2)[Parts]-[Basic]-[AlignmentType]is[FlipChip]
2.Makethepairoftwodatumballsin[No.1]and[No.2]on[Edit]-[BALLEdit]-
[RandomBallEdit]dialog.
3.Appointthepairvalueat[DatumBallPosition]columnexceptthepairof"[0]-[1]"
or"[2]-[3]","[4]-[5]","[6]-[7]",andclickOKbutton.
4.Theerrormessage"Ea12517:ILLEGALDATUMBALLDATA"isnotdisplayed,and
wrongboarddatamentionedaboveismade.
Itisfixed.
3.06 1.001
TT3419
TT3419TT3419
TT3419
TT3438
TT3438TT3438
TT3438
30
3030
30 Bug Editor Boarddata
Whenthefollowingprocedureswereexecuted,therewasabugthattheboarddatawas
notsaved.
1.Displaytheboarddatasavedialogfrom[File]-[SaveBoardDataAs].
2.Inputtheboarddataname.
3.Pushthe[Enter]key.
Itisfixed.
3.06 1.001 TT3566
TT3566TT3566
TT3566 31
3131
31 Bug Optimizer CTestimation
Whenthefollowingprocedureswereexecuted,therewasabugthatOptimizationorCT
estimationoccasionallyfailed.
1.ThemachineisYS12orYG12.
2.[MachineData]-[Station]-[NozzleStation]-[stationMACS]-[Execute]isnot
"NotUse".
3.Usetheboarddataincludingallthefollowingconditions
1)Thepartsthatusedifferentnozzlesrespectivelyexist.
2)ThepartswhosebodysizeexceedsthesizethatcanberecognizedbyScan
Cameraexist.
4.ExecuteOptimizationorCTestimation,and"Ea17904:CycleTimeEstimationError"
occurs.
Itisfixed.
3.06 1.001 TT3652
TT3652TT3652
TT3652 32
3232
32 Bug Optimizer CTestimation
Whenthefollowingprocedureswereexecuted,therewasabugthatOptimizationorCT
estimationoccasionallyfailed.
1.ThemachineisYG300orYS12orYG12orYS100orYS88.
2.[MachineData]-[Mechanical]-[Position]-[MountBlowMode]is"NORMAL".
3.Usetheboarddataincludingallthefollowingpartsdata.
1)[Parts]-[Basic]-[RequiredNozzle]isthenozzlethatusesaddblow.
2)[Parts]-[Mount]-[MountAction]is"DETAIL".
3)[Parts]-[Mount]-[MountUp]is"2StepFast"or"2StepMiddle"or"2StepLow".
4.ExecuteOptimizationorCTestimation,and"Ea17904:CycleTimeEstimationError"
occurs.
Itisfixed.
3.06 1.001 TT3534
TT3534TT3534
TT3534 33
3333
33 Bug Optimizer NozzleType
Whenthefollowingprocedureswereexecuted,therewasabugthattheoptimizer
programabnormalendoccurredduringoptimization.
1.Executetheoptimizationoftheboarddatawhichhavethefollowingparts
information.[MachineProperty]-[SpecificationInformation]-[MountNozzle
Specification]-[NozzleType]wasTYPE-***Z.
Itisfixed.
3.06 1.001 TT3292
TT3292TT3292
TT3292 34
3434
34 Bug Optimizer Nozzlechange
Therewasabugthattheoptimizermightmaketheboarddatawhichincludedthe
unnecessarynozzlechange.
Itisfixed.
MDOC-VG30-00001 93/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.06 1.001 TT3476
TT3476TT3476
TT3476 35
3535
35 Bug Optimizer Feeder
Whenthefollowingprocedureswereexecuted,therewasabugthattheoptimizer
programabnormalendoccurredduringoptimization.
1.Theboarddatahasthepartsdatawhichhasinvalidfeedersetnumber
2.Thepartsbelongstothemulti-tablemachine.
3.Executeoptimizationwiththesetting"MoveWithinTable"or"MoveWithinFeeder
Plate"or"AllPartsFixed"to"FeederSetCondition".
Itisfixed.
3.06 1.001 TT3122
TT3122TT3122
TT3122 36
3636
36 Bug Optimizer Fixedboard
Whenthefollowingprocedureswereexecuted,therewasabugthattheoptimizer
programabnormalendoccurredduringoptimization.
1.Theboarddatahasthesamenamepartsdatawhichhavedifferentrequirednozzles.
2.Thelinehasthemachinewhichhas"ManualNozzleChangeHead".
3.Execute"CommonOptimizationSetting"or"FixedBoard".
Itisfixed.
3.06 1.001 TT3519
TT3519TT3519
TT3519 37
3737
37 Bug Optimizer PartsInfo
Whenthefollowingprocedureswereexecuted,therewasabugthattheoptimizer
programabnormalendoccurredduringoptimization.
1.[Setoptimizationparameter]-[ExecOption]-[Heightdifferencetopermit
overtaking]ischecked.
2.Executetheoptimizationoftheboarddatawhichhavethefollowingparts
information.Thedifferenceof[Parts]-[Shape]-[BodySizeZ(mm)]oftwopartsis
almostthesamesizeas[Heightdifferencetopermitovertaking].
Itisfixed.
3.06 1.010 TT3794
TT3794TT3794
TT3794 1
11
1 CriticalBug
CriticalBugCriticalBug
CriticalBug YS12,YG12 ScanCamera
Whenthefollowingconditionwassatisfied,therewasapossibilityofthenozzledamage
becauseofinterferencebetweenthenozzleandthescan-camera.
1.TheemergencystopoccurswhentheX-axisismoving.(ex.Pushtheemergency
button,Openthefront/rearcover.)
Itisfixed.
3.07 1.000 UD1189
UD1189UD1189
UD1189 1
11
1
Important
ImportantImportant
Important
Add
AddAdd
Add
All
Application
Database
When[READDATABASE]or[WRITEDATABASE]wereexecuted,thefunctionwas
addedthattheparameterfortherelationofPickpositionandTraycouldalsobe
managed.
Theaboveparameterswereoutofmanagementsbecausetheywerestronger
dependingontheenvironmentsbefore.Dependingoncustomeroperations,this
additionalfunctioncancontributethestandardizationofdataorintegration.
Itismodified.
*
3.07 1.000 TM1118
TM1118TM1118
TM1118 2
22
2
Important
ImportantImportant
Important
Add
AddAdd
Add
YS100
QFPDump
Station
Thefunctionwasaddedtousefollowingoptionsforthemachinesnon-equippedwith
therearfeederplates.
1.StandTypeQFPdumpstation
Itismodified.
*
3.07 1.000 TM1118
TM1118TM1118
TM1118 3
33
3
Important
ImportantImportant
Important
Add
AddAdd
Add
YS100,YS12
P,YS12F
Tray
Thefunctionavailableforusingthe[YSseriesmanualtray]optionwasaddedtothe
machinesofnon-equippedrearfeederplates.
Itismodified.
*
3.07 1.000 TM1133
TM1133TM1133
TM1133 4
44
4
Important
ImportantImportant
Important
Add
AddAdd
Add
YS12P,
YS12F
Added
Machine
Thefollowingmachinesweresupported.
1.YS12P
2.YS12F
Itismodified.
3.07 1.000 TT3736
TT3736TT3736
TT3736 5
55
5 CriticalBug
CriticalBugCriticalBug
CriticalBug Mounter ConveyorOut
Whenthefollowingprocedureswereexecuted,therewasabugthattheexitstopper
pusheduptheboard.
1.Starttheauto-runningafterallofthefollowingconditionsweresatisfied,
1)TheYamahamounterexistsintheupstreammachine.
2)The[Setting]-[MachineInformation]-[InstallationSetting]-[Software]-
[Handing]is"ADVANCEDGATE".
2.Themountedboardexistontheexitpositionandthemountingpositioninthe
upstreammachine.
3.Theboardistransportedfromtheupstreammachinetothedownstreammachine,
andthetransferislimping.
4.Whentheboardisdetectedattheentrancesensorofthedownstreammachine,the
exitstopperoftheupstreammachineisraised.
Itisfixed.
3.07 1.000 TT3813
TT3813TT3813
TT3813 6
66
6 CriticalBug
CriticalBugCriticalBug
CriticalBug YS100,YS88 Conveyor
Whenallofthefollowingconditionsweresatisfied,therewasabugthatthebackuppin
wasbrokenbecausetheConv.WidthSafetySensordidnotworkwhentheconveyer
widthwasnarrowed.
1.Underthe[Setting]-[MachineInformation]-[InstallationSetting]
1)The[TrayChanger]-[TrayChangerType]is"Ext.TC_YS"
2)The[Conveyor]-[BufferConv.Type]is"A-TYPE"
3)The[Option]-[Conv.WidthSafetySensor]is"Exist"
2.Thebackuppinexistswithinabout30mmfromtheconveyer.
Itisfixed.
3.07 1.000 TM0886
TM0886TM0886
TM0886 7
77
7 Add Mounter ErrorMessage
Whentheconveyerwidthwasdifferentfromtheboardwidthatthemachinerestarted
time,theconveyernameandmismatchedlengthdisplayingfunctionwereaddedinthe
followingerrormessages.
Ea7329:Theconveyerwidthisnotintherightplace.
Ea7330:Thebufferconveyerwidthisnotintherightplace.
Ea7331:Theconveyerwidthisnotintherightplace.
Itismodified.
MDOC-VG30-00001 94/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.07 1.000 TP0803
TP0803TP0803
TP0803 8
88
8 Add
YSSeries
mounter,
__YG12__
Operation
Panel
Thefunctionwasaddedthatthefollowingoperationpanelbuttoncouldoperatethe
buttonofthemessagescreen.
1.Whenthemessagescreenhasonebutton,the[STOP]buttoncanoperateit.
2.Whenthemessagescreenhastwobuttons,the[START],[STOP]buttoncanoperate
it.
3.Whenthemessagescreenhasthreebuttons,the[START],[STOP]and[ERROR
CLEAR]buttoncanoperateit.
Thisfunctionisavailablewhenthe[Setting]-[SpecificationInformation]-[Panel
Specification]-[ButtonFunction]is"Extend".
Itismodified.
3.07 1.000 TT3560
TT3560TT3560
TT3560 9
99
9 Add Optimizer NozzleChange
Theoptimizationperformanceofthenozzlereturnactionwasimproved.
Thecycletimemightgetbettermorethan10%whentheboarddatahadmanynozzle
returnaction.
Itismodified.
3.07 1.000 TT3806
TT3806TT3806
TT3806 10
1010
10 Change
YSSeries
mounter
GUI
ThefollowingbuttonnamewaschangedontheYSseries.
1.Thenameofthe[Unit]-[Feeder]-[CartInformation]buttonischangedto[Plate
Information]button.
Itismodified.
3.07 1.000 TT3634
TT3634TT3634
TT3634 11
1111
11 Bug Mounter GUI
Whenoneorotherofthefollowingconditionswassatisfied,therewasabugthatthe
buttononthe[Unit]-[Conveyor]screenwasnotcorrespondingtothefunctional
behavior.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[ConveyorDirection]
is"L->R"andthe[Setting]-[MachineInformation]-[InstallationSetting]-[Twin
PushUp]is"Exit".
Whenthe[MainStopper],[PushUp]or[BoardClamp]buttonisclicked,theother
sidestagemoves.
2.Therearsideisselectedbythe[OperationPanel]-[ACTIVE]button,
Whenthe[Left]or[Right]buttonisclicked,theactualmovingdirectionisoppositeto
thearrowonthebutton.
Itisfixed.
3.07 1.000 TT3634
TT3634TT3634
TT3634 12
1212
12 Bug Mounter GUI
Whenthefollowingconditionsweresatisfied,therewasabugthattheconveyorarrow
onthe[Monitor]-[Production]screenwasdisplayedastheoppositedirection.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[ConveyorDirection]
is"L->R".
Itisfixed.
3.07 1.000 TT3538
TT3538TT3538
TT3538 13
1313
13 Bug Mounter Warmup
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
stoppedsoonevenifwarming-upstarted.
1.Someerrormessagesaredisplayed,afterthattheerrormessagesscreenarehidden
bythe[Close]button.
2.Clickthe[Setup]-[WarmUp]-[Start]button.
Itisfixed.
3.07 1.000 TT3804
TT3804TT3804
TT3804 14
1414
14 Bug Mounter ErrorMessage
Whenthefollowingerroroccurredby[Setup]-[SystemBackup],therewasabugthat
thecontentsofthe[Drive]andthe[Connect]werenotdisplayed.
1.Ea2912-Ea2921:SYSTEMBACKUPERROR
2.Ea2927:SYSTEMBACKUPWARNING
Itisfixed.
3.07 1.000 TT3841
TT3841TT3841
TT3841 15
1515
15 Bug Mounter Coplanarity
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
applicationabnormalendoccurred.
1.Selectthe[Setup]-[SoftwareSetting]-[Basic]-[Co-PlanarityChecker]-[3D
RecognitionResult]isexceptfor"NoSave".
2.CreatetheboarddatathatexecutestheCo-Planarityrecognition,andstartauto-
running.
3.The[Ea5leadnumbererror]erroroccurs.
4.Clickthe[ERRORCLEAR]button(NotexecuteReset).
5.Clickthe[Parts]-[PartsAdj]-[Test]button.
Itisfixed.
3.07 1.000 TT3840
TT3840TT3840
TT3840 16
1616
16 Bug Mounter Teach
Therewasabugthatthe[Jump]screencouldnotopenevenifthe[Jump]buttonwas
clickedintheteachscreen.The[Jump]buttonsofallteachscreenswereaffected.
Itisfixed.
3.07 1.000 TT3597
TT3597TT3597
TT3597 17
1717
17 Bug Mounter Trace
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
applicationabnormalendmightoccur.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[TrayChanger]-
[TrayChangerType]is"None".
2.The[Parts]-[Basic]-[FeederType]is"Ext.TC"or"AutoTC".
3.Selectthepartsoftheabove2onthepartsinformationscreen,andclickthe
[Teach]-[Trace]button.
Itisfixed.