OM-1076-001.pdf - 第122页

(a) When the recognition cannot be made correctly due to improper light- ing condition, set proper lighting patterns for the selected component. (b) When "Back Ltg System" is selected in the "Lighting Syst…

100%1 / 237
(B02_05) Lighting Pattern
Set a lighting pattern to be used for component recognition.
Applicable Components : Applicable for all subjected components
(1) Ltg Pattern Designation
Select one of the following options to designate a lighting pattern.
Auto : The lighting patterns are automatically set for all lighting
units.
Manual : The lighting patterns can be set individually for each light-
ing unit.
0111-002 2-90
Tg0502-PM-CL
B02 Recognition Data (B02_05)
Fig. B194
Auto
Ltg pattern designation
Fig. B192 Edit Window (Example) for Cylindrical Components
Fig. B193
(a) When the recognition cannot be made correctly due to improper light-
ing condition, set proper lighting patterns for the selected component.
(b) When "Back Ltg System" is selected in the "Lighting System" text
box, the recognition is processed based on the recognition algorithm
for the back lighting system. When "Front Ltg System" is selected,
the recognition is processed based on the recognition algorithm for
the front lighting system.
(c) To set a parameter, select "Manual" in the "Recognition data set" text
box.
(2) Lightening Pattern Back Ltg
When the Lighting Pattern Designation is set to "Manual", select the
pattern for the back lighting recognition lamp from the following op-
tions:
Off Std
80%
60%
40%
20%
++
++
+20%
++
++
+40%
++
++
+60%
++
++
+80%
(3) Lightening Pattern Front Ltg (Up)
When the Lighting Pattern Designation is set to "Manual", select the
lighting pattern for the front lighting recognition lamp on the upper
side (mainly used for the BGA components) from the following op-
tions:
Off Std
80%
60%
40%
20%
++
++
+20%
++
++
+40%
++
++
+60%
++
++
+80%
(4) Lightening Pattern Front Ltg (Mid)
When the Lighting Pattern Designation is set to "Manual", select the
lighting pattern for the front lighting recognition lamp on the middle
side from the following options.
Off Std
80%
60%
40%
20%
++
++
+20%
++
++
+40%
++
++
+60%
++
++
+80%
(5) Lightening Pattern Front Ltg (Dn)
When the Lighting Pattern Designation is set to "Manual", select the
lighting pattern for the front lighting recognition lamp on the lower side
from the following options.
Off Std
80%
60%
40%
20%
++
++
+20%
++
++
+40%
++
++
+60%
++
++
+80%
0111-002 2-91
Tg0502-PM-CL
B02 Recognition Data (B02_05)
Fig. B197
Off
Front ltg (Mid)
Fig. B198
Off
Front ltg (Dn)
Fig. B196
Off
Front ltg (Up)
Off
Back ltg
Fig. B195
(B02_06) View Range Set
Select the view range used in the recognition operation from the fol-
lowing options.
Auto Selection : "Large View" or "Small View" can be selected au-
tomatically according to the selected component.
Small View : Select this when small view (movable camera) is
to be used.
"Small View" can be used only for the component which satisfies
the following conditions 1 or 2.
(Conditions 1)
· [Outward Length X Direction + Pickup Pos Correction X
×
2]
=< 24 mm
· [Outward Length Y Direction + Pickup Pos Correction Y
×
2]
=< 18 mm
· [Component Thickness (t + Ut) ] =< 5 mm
(Conditions 2)
· [Outward Length X Direction + Pickup Pos Correction X
×
2]
=< 10 mm
· [Outward Length Y Direction + Pickup Pos Correction Y
×
2]
=< 10 mm
· [Component Thickness (t + Ut) ] =< 6.5 mm
If neither condition 1 nor condition 2 is satisfied, the Error
display appears.
Large View : Select this when large view (fixed camera) is
to be used.
Min View (Option) : Select this when large view (fixed camera) is
to be used.
(a) Select "Auto Selection" in normal cases.
(b) Set this only when "Manual" is selected in the "Recognition data set"
text box.
(c) For the Minimum View, the Compound Eye View (Option) setting is
required. Consult our marketing department or sales agency for de-
tails.
Applicable Components : Applicable for all subjected components
B02 Recognition Data (B02_06)
Fig. B199
Auto Selection
View range set
0206-003 2-92 Tg0502-PM-CL