4OM-1626-001_w.pdf - 第147页

4OM-1610 3-16 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 Error ID Error Name, Description, Cause, and Remedy 4008E3 Servo Alarm Absolute position counter warning Perform noise strategies of encoder or exchan…

100%1 / 251
4OM-1610
3-15
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
400845 Servo Alarm
Main circuit elem overheat
Drive with blocking tact, or take the ambient temperature of the Amplier down.
400846 Servo Alarm
Servo Motor overheat
Drive with blocking tact, or take the ambient temperature of the Motor down,
400847 Servo Alarm
Cooling Fan Error
Exchange cooling fan of Servo Amplier
400850 Servo Alarm
Overload1
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
400851 Servo Alarm
Overload2
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
400852 Servo Alarm
Error in excess
Please check whether there is no error in Sliding detect of a driving system or in
motor wiring or not.
40088A Servo Alarm
USB communication time-out
-----
40088B Servo Alarm
USB Communication Error
-----
400891 Servo Alarm
Multi-axes Amplier Temperature warning
Take the ambient temperature of the multi-axes amplier down.
400892 Servo Alarm
Battery disconnection warning
----
400896 Servo Alarm
Zero set miss alarm
-----
40089F Servo Alarm
Battery warning
-----
4008E0 Servo Alarm
Over-Regenerative alarm
Drive with blocking tact.
4008E1 Servo Alarm
Overload alarm1
Drive with blocking Tact.
4OM-1610
3-16
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
4008E3 Servo Alarm
Absolute position counter warning
Perform noise strategies of encoder or exchange servo amplier.
4008E4 Servo Alarm
Parameter warning
Check out servo parameter.
4008E6 Servo Alarm
Servo forced stop alarm
EM1, emergency stop input of Servo amplier is off.
4008E7 Servo Alarm
Controller emergency stopping warning
outputted emergency stop from Controller.
4008E8 Servo Alarm
No. of Rot dropping warning of Cooling Fan
Exchange the Cooling fan.
4008E9 Servo Alarm
Main circuit off warning
Main circuit is Off.
4008EB Servo Alarm
another axis warning
Error in another axis in the same P.C.B. Please remove the factor of error.
4008EC Servo Alarm
Overload alarm2
Drive with blocking tact.
4008ED Servo Alarm
Output Watt over warning
Driver with blocking Tact.
400911 Servo Alarm
Power drive Error, Over-current
Check out motor wiring or exchange both motor and driver
400921 Servo Alarm
Overload Alarm
Check out motor wiring or exchange both motor and driver. Either, Conrm that
the blocking exists with cutter pieces.
400931 Servo Alarm
Speed Alarm
Readjust motor gain.
400941 Servo Alarm
multi-cycle Error
Check out the motor wiring or exchange the motor.
400942 Servo Alarm
The value of variation counter is out of the range
Check out the wiring of Origin sensor. Or, Exchange driver.
400951 Servo Alarm
Power Drive detected temperature error
Ambient Temperature is high. Exchange driver.
4OM-1610
3-17
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
400961 Servo Alarm
Sensor Error
Check Motor Encoder wires. Or, exchange the motor.
400962 Servo Alarm
Sensor Error
Check Motor Encoder wires. Or, exchange the motor.
400971 Servo Alarm
high drive Voltage
Insufcient power. Exchange driver.
400972 Servo Alarm
Low drive Voltage
Check out the drive power wiring putted in Driver. Or, check out DC48V.
400991 Servo Alarm
Reading Error on permanent memory
Exchange the driver.
400992 Servo Alarm
Writing Error on permanent memory
Exchange the driver.
400998 Servo Alarm
CPU Error
Exchange the driver.
400999 Servo Alarm
Parameter Error
Conrm the changed value of Parameter.
400a08 Head Interlock Error
Releasing the brake is impossible during Servo On.
-----
400b01 Feeder preparation complete
A pick up miss comp or disengaged Latch was detected.
Open the safety cover and conrm that there is no interference with the head, and
then, release the ready feeder.
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Please conrm the lower bound detection 1 sensor of nozzle stock unit.
400c02 Nozzle stocker down time out
Nozzle stock unit lower bound detection 2 was not turned on in prescribed time.
Please conrm the lower bound detection 2 sensor of nozzle stock unit.
400c03 Nozzle stocker down time out
Nozzle stock unit lower bound detection 3 was not turned on in prescribed time.
Please conrm the lower bound detection 3 sensor of nozzle stock unit.
400c04 Nozzle stocker down time out
Nozzle stock unit lower bound detection 4 was not turned on in prescribed time.
Please conrm the lower bound detection 4 sensor of nozzle stock unit.
400d01 Software Interlock Error
Head (Rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.
0911-001