4OM-1610 3-50 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 Error ID Error Name, Description, Cause, and Remedy 426301 positioning conveyor Error Error in positioning conveyor ----- 427101 Detection of Output c…

100%1 / 251
4OM-1610
3-49
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
42610c Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2. There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
42610d Detection of positioning conveyor sensor
Decrease sensor of output position was detected after starting.
There is an indenite P.C.B. on Output position stop sensor.
Please remove P.C.B..
42610e Detection of positioning conveyor sensor
Decrease sensor of output position was not detected after starting.
-----
42610f Detection of positioning conveyor sensor
Stop sensor of output position was detected before starting.
There is an indenite P.C.B. on Output position stop sensor.
Please remove P.C.B..
426110 Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
426111 Detection of positioning conveyor sensor
P.C.B. on positioning conveyor was detected
Please remove P.C.B. from positioning conveyor.
426112 Detection of positioning conveyor sensor
NO P.C.B. on positioning conveyor
Conrm whether P.C.B. is not dropping.
Conrm whether Sensor is not broken.
426201 positioning conveyor timeout
Placement for input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input conveyor to Input
position or is dropped. Please conrm from Input to positioning conveyor.
426202 positioning conveyor timeout
Output from input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.
Please conrm from positioning to Output conveyor.
426203 positioning conveyor timeout
Placement for output position was not completed within predetermined time.
P.C.B. inserted is place in Output position.
There is a possibility of it fallen. Please conrm from Input to Positioning conveyor.
426204 positioning conveyor timeout
Output from output position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.
Please conrm from positioning to Output conveyor.
4OM-1610
3-50
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
426301 positioning conveyor Error
Error in positioning conveyor
-----
427101 Detection of Output conveyor sensor
Decrease sensor was detected before starting.
There is an indenite P.C.B. on Output conveyor.
Please remove it.
427102 Detection of Output conveyor sensor
Decrease sensor was not detected before starting the movement
P.C.B. to output is not found
1. Please put P.C.B. on Sensor.
2. There is a possibility of P.C.B. fallen. Conrm the conveyor width.
427103 Detection of Output conveyor sensor
Stop sensor was detected before starting.
There is an indenite P.C.B.. Please remove it.
427104 Detection of Output conveyor sensor
Stop sensor was not detected before starting.
Cannot nd P.C.B. to output.
1. Is P.C.B. detected by sensor?
2. There is a possibility that P.C.B. is falling. Please check the width of conveyor.
427105 Detection of Output conveyor sensor
P.C.B. on decrease sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427106 Detection of Output conveyor sensor
P.C.B. on decrease sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
427107 Detection of Output conveyor sensor
P.C.B. on stop sensor was detected after movement completion
There is an indenite P.C.B. on Output conveyor. Please remove it.
427108 Detection of Output conveyor sensor
P.C.B. on stop sensor was not detected after movement completion
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
427109 Detection of Output conveyor sensor
P.C.B. on output conveyor was detected
Please remove P.C.B. from the conveyor
42710a Detection of Output conveyor sensor
P.C.B. on output conveyor was not detected
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
42710b Detection of Output conveyor sensor
Stop sensor is not passed during Output operation
The conveyor is stopped before P.C.B. goes through Sensor.
1. Conrm output method, transition speed, timer setting.
2. Check the connected cable.
4OM-1610
3-51
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
42710c Detection of Output conveyor sensor
Disengaged P.C.B. of output conveyor
P.C.B. was removed from Output Conveyor.
Please check the state of it if removing P.C.B. does not happen intentionally.
42710d Detection of Output conveyor sensor
P.C.B. was not inserted into output conveyor
Please Remove P.C.B. inserted.
427201 Output conveyor timeout
Placement was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the above conveyor.
427202 Output conveyor timeout
Output was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the transition with Output Machine.
427301 Output Conveyor Error
Error while output conveyor is moving.
-----
427401 Middle Conveyor Error
Time-out in Placement from Input Machine.
PCB is not placed in Device. Please check Middle Conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
If PCB is on Middle Conveyor, whether remove it, or put it on Input conveyor.
427402 Middle Conveyor Error
Time-out in Output for Output Machine.
PCB is not outputted from Device. Please check Middle conveyor.
1. Whether Emergency stop is pressed
2. Whether Safety Cover is open
3. Whether Breaker is falling down
428001 Error in the communication of P.C.B. transfer
Input Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of Input Machine.
2. Check the connected cable.
428002 Error in the communication of P.C.B. transfer
Output Machine signal cutting
A signal of work request for the output machine was cut off while P.C.B. is placing.
1. Please check the transfer method of output Machine.
2. Check the connected cable.
428101 Line PCB transfer error
Time-out of Placement
Line PCB transfer was not completed in prescribed time.
1. There is a possibility that PCB is caught. Please Check the Conveyor.
2. Please conrm whether Connect cable is normally connected or not.
0911-001