4OM-1626-001_w.pdf - 第193页

4OM-1610 3-62 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 49077C Nozzle set up Error in recognizing Noz Stocker Mark ----- 49077D Nozzle set up Recognizing Noz Stocke…

100%1 / 251
4OM-1610
3-61
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
49076E Nozzle set up
Turning on PCB recog camera Light has not nished within predetermined time
-----
49076F Nozzle set up
Error in turning on PCB recog camera Light
-----
490770 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490771 Nozzle set up
Turning on PCB recog camera Light has not nished within predetermined time
(Teaching Noz Stocker)
-----
490772 Nozzle set up
Error in turning on PCB recog camera Light (Teaching Noz Stocker)
-----
490773 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490774 Nozzle set up
Turning on PCB recog camera Light has not nished within predetermined time
(Noz Recog)
-----
490775 Nozzle set up
Error in turning on PCB recog camera Light (Noz Recog)
-----
490776 Nozzle set up
Error in turning off PCB recog camera Light
-----
490777 Nozzle set up
Turning off PCB recog camera Light has not nished within predetermined time
-----
490778 Nozzle set up
Error in turning off PCB recog camera Light
-----
490779 Nozzle set up
Error in capturing a image of PCB recog camera.
-----
49077A Nozzle set up
Capturing a image of PCB recog camera has not nished within predetermined
time
-----
49077B Nozzle set up
Error in capturing a image of PCB recog camera.
-----
4OM-1610
3-62
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49077C Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077D Nozzle set up
Recognizing Noz Stocker Mark has not nished within predetermined time.
-----
49077E Nozzle set up
Error in recognizing Noz Stocker Mark
-----
49077F Nozzle set up
Error in recognization of the existence of Noz
-----
490780 Nozzle set up
Recognization of the existence of Noz has not nished within predetermined time
-----
490781 Nozzle set up
Error in recognizing the existence of Noz
-----
490782 Nozzle set up
Error in recognizing Noz ID
-----
490783 Nozzle set up
Recognizing Noz ID has not nished within predetermined time
-----
490784 Nozzle set up
Error in recognizing of Noz ID
-----
490785 Nozzle set up
Time-out of starting linear Measure detect
-----
490786 Nozzle set up
Time-out of reading out the result of Linear Measure detect
-----
490787 Nozzle set up
Error in the result of Linear Measure detect
-----
490788 Nozzle set up
Time-out of starting linear Measure detect (Noz diameter Recog)
-----
490789 Nozzle set up
Time-out of reading out the result of Linear Measure detect (Noz diameter Recog)
-----
49078A Nozzle set up
Error in the result of Linear Measure detect (Noz diameter Recog)
-----
0911-001
4OM-1610
3-63
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
49078B Nozzle set up
Failed in getting Noz type Data.
-----
49078C Nozzle set up
Exchanging Noz has not started within predetermined time
-----
49078D Nozzle set up
Exchanging Noz has not nished within predetermined time
-----
49078E Nozzle set up
Error in setting Drive Wave of HL-axis
-----
49078F Nozzle set up
Error in setting Drive Wave of NL-axis
-----
490790 Nozzle set up
Error in setting Drive Wave of L-axis
-----
490791 Nozzle set up
Error in coordinate calculation of shifting the Origin
-----
490792 Nozzle set up
Error in setting Sequence Data of HL-axis
-----
490793 Nozzle set up
Error in HL-axis operating
-----
490794 Nozzle set up
Error in L-axis operating
-----
490801 Program -change linked operation
Program-change linked operation has not nished within appointed time.
-----
496001 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W1-axis operating.
Please remove the Backup Pin/Jig from Backup Base. Or, confirm whether
Sensor has error or not.
496002 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W2-axis operating.
Please remove the Backup Pin/Jig from Backup Base. Or, confirm whether
Sensor has error or not.
496003 Conveyor Width Backup Pin detected
Backup Pin/Jig was detected during N1_W3-axis operating
Please remove the Backup Pin/Jig from Backup Base. Or, confirm whether
Sensor has error or not.
0911-001