4OM-1626-001_w.pdf - 第196页

4OM-1610 3-65 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 4961 18 Conveyor Width W1 Error Motor Disconnection of Conveyor Width W1 was detected. Disconnection to moto…

100%1 / 251
4OM-1610
3-64
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
496101 Conveyor Width W1 Error
Drive Alarm during Conveyor Width W1 axial operation.
Conrm reset Method of detailed Sub-system error counts of Alarm.
496102 Conveyor Width W1 Error
Conveyor Width W1-axis could not start
A state in which the operating command is not normally accepted.
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate se
496110 Conveyor Width W1 Error
System setup of Conveyor Width W1 is not completed.
Driver has not completed the parameter setup yet. It is a situation in which
a correct setup has not been received by Communication Error. Check the
Communication Mode, wiring, Power supply of Driver.
496111 Conveyor Width W1 Error
Zeroing Error in Conveyor Width W1
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
496112 Conveyor Width W1 Error
Out-of-Control in Conveyor Width W1
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure
motor Error.
496113 Conveyor Width W1 Error
Error in Motor Power voltage of Conveyor Width W1
Motor power voltage dropped.
Check out the Power supply line(48V Line)
496114 Conveyor Width W1 Error
STP input in Conveyor Width W1 was detected
STP input is detected. The function to stop motor by Hard signal.
496115 Conveyor Width W1 Error
Over-current in Conveyor Width W1
Error in Motor output line.
Check out the motor wiring,
496116 Conveyor Width W1 Error
Limit Sensor(+) was detected in Conveyor Width W1.
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
496117 Conveyor Width W1 Error
Limit Sensor(-) was detected in Conveyor Width W1.
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
0911-001
4OM-1610
3-65
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
496118 Conveyor Width W1 Error
Motor Disconnection of Conveyor Width W1 was detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
496119 Conveyor Width W1 Error
Control Power Voltage of Conveyor Width W1 has error
Control power for driver dropped.
Check out the Power supply line.(24V Line)
49611a Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49611b Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49611c Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49611d Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49611e Conveyor Width W1 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
49611f Conveyor Width W1 Error
System Error in Conveyor Width W1.
System Error of internal driver.
Driver error is supposed if this problem happens frequently.
496120 Conveyor Width W1 Error
Communication Error in Conveyor Width W1.
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate setting.
496201 Conveyor Width W2 Error
Drive Alarm during Conveyor Width W2 axial operation.
Conrm reset Method of detailed Sub-system error counts of Alarm.
496202 Conveyor Width W2 Error
Conveyor Width W2-axis could not start
A state in which the operating command is not normally accepted.
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate se
0911-001
4OM-1610
3-66
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
496210 Conveyor Width W2 Error
System setup of Conveyor Width W2 is not completed.
Driver has not completed the parameter setup yet.
It is a situation in which a correct setup has not been received by Communication
Error.
Check the Communication Mode, wiring, Power supply of Driver.
496211 Conveyor Width W2 Error
Zeroing Error in Conveyor Width W2
LS, discontinuous zeroing movement, was detected.
Check out the dirt, error of sensor and error in Motor body etc.
496212 Conveyor Width W2 Error
Out-of-Control in Conveyor Width W2
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production.
Please set motor speed slow if it happens frequently. Also, in a case of structure
motor Error.
496213 Conveyor Width W2 Error
Error in Motor Power voltage of Conveyor Width W2
Motor power voltage dropped. Check out the Power supply line(48V Line)
496214 Conveyor Width W2 Error
STP input in Conveyor Width W2 was detected
STP input is detected. The function to stop motor by Hard signal.
496215 Conveyor Width W2 Error
Over-current in Conveyor Width W2
Error in Motor output line.
Check out the motor wiring,
496216 Conveyor Width W2 Error
Limit Sensor(+) was detected in Conveyor Width W2.
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
496217 Conveyor Width W2 Error
Limit Sensor(-) was detected in Conveyor Width W2.
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
496218 Conveyor Width W2 Error
Motor Disconnection of Conveyor Width W2 was detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
496219 Conveyor Width W2 Error
Control Power Voltage of Conveyor Width W2 has an error
Control power for driver dropped.
Check out the Power supply line.(24V Line)
49621a Conveyor Width W2 Error
-----
Reserved Function of driver. Please make inquiries when error is detected.
0911-001