4OM-1626-001_w.pdf - 第206页

4OM-1610 3-75 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 Error ID Error Name, Description, Cause, and Remedy 4b0501 Manual alignment Error Operation was not completed within predetermined time. ----- 4b050f …

100%1 / 251
4OM-1610
3-74
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
4b0310 Feeder Base
The power was not turned on, or emergency stop was detected.
Please turn on the machine after conrm that Emergency Stop button is not
pressed.
4b0311 Feeder Base
Feeder Cart could not be detected.
Please execute operation again after setting Feeder Cart in predetermined place.
Please conrm whether it set in if the set is already done well.
4b0312 Feeder Base
Connector of Feeder Cart is not connected
Please execute operation again after connecting connector of Feeder Cutter.
4b0313 Feeder Base
NL-axis interlock was detected
Please execute zeroing when NL-axis is fallen.
4b0314 Feeder Base
Error in Feeder Base movement
-----
4b0315 Feeder Base
Time-out in Clamp Movement of Elevator Unit
-----
4b0316 Feeder Base
Time-out in Unclamp Movement of Elevator Unit
-----
4b0317 Feeder Base
Illegal current position of Feeder base (Rear)
Please conrm Feeder base, and the sensor of Cylinder Upper limit
detection[B0614], Cylinder Lower limit detection[B0615].
4b0318 Feeder Base
Illegal current position of Feeder base (Front)
Please conrm Feeder base, and the sensor of Cylinder Upper limit
detection[B0614], Cylinder Lower limit detection[B0615].
4b0319 Feeder Base
Positioning dropping prevention stopper(Rear) cannot cancel lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4b031A Feeder Base
Positioning dropping prevention stopper(Front) cannot cancel lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4b031B Feeder Base
Positioning dropping prevention stopper(Rear) cannot lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4b031C Feeder Base
Positioning dropping prevention stopper(Front) cannot lock.
Please conrm the state of Feeder base and detect sensor of positioning drop
prevention lock[B0912][B0913]
4OM-1610
3-75
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
4b0501 Manual alignment Error
Operation was not completed within predetermined time.
-----
4b050f Manual alignment Error
Error was detected during operation.
-----
4b0701 Connection Error.
Failed in communications with the Control CPU.
-----
4b0702 Connection Error.
Failed in communications with the Recog. CPU.
-----
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
There is a possibility of Light Emitter and Receiver broken.
Please conrm Error from Log Request Screen(Unit adjustment → Linear
measure Sensor Screen)
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
Communication connector of Linear measure Sensor P.C.B is taken off.
Please conrm whether the items of LS-RLS-S(Device Check → List) is Y
ellow.
HLS communication cable could not be connected and such like things.
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Light Emitter and Receiver could have aw and soil. Please clean it up.
Please press [Operation] on the screen(Unit adjustment → Linear measure
Sensor → Detection test Screen) and conrm whether there is an error
4b0804 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken
4b0805 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
A small light quantity of Light Emitter. Please exchange Light Emitter.
4b0806 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
There is a possibility of Line Sensor P.C.B. broken.
Either
, Please update Version on the screen(Unit adjustment → Linear measure
Sensor → Correct data read Screen)
4b0807 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Please conrm Error from Log Request Screen(Unit adjustment → Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check -> List) is Yellow. HLS communication cable could not be
connected and such like things.
4OM-1610
3-76
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
4b0808 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
Please conrm Error from Log Request Screen(Unit adjustment → Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check → List) is Yellow. HLS communication cable could not be
connected and such like things.
4b0809 Linear measure operation error
There is a problem in the linear measure Sensor.
(Strobe Signal did not turn off within predetermined time.)
Please conrm Error from Log Request Screen(Unit adjustment → Linear
measure Sensor Screen). Either, please conrm whether the items of LS-RLS-
S(Device Check → List) is Yellow. HLS communication cable could not be
connected and such like things.
4b0c01 Nozzle Conrmation Error before pick up comp (Detect After Placement)
Because a component was found on a nozzle, it stopped after disposal. The result
could have some problems.
Please check placement state on placement step recovery screen.
4b0c02 Nozzle Conrmation Error before pick up comp
The remains component was found on a nozzle during production.
Please conrm whether there is an error in the P.C.B.
4b0c03 Nozzle Conrmation Error before pick up comp (Detect After Discard)
Because a component was found on a nozzle, it stopped after disposal.
Please conrm and clean up the nozzle if this error continues.
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and conrm the component on P.C.B. Please remove it or
revise it
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please conrm the cable of SSC network.
4b2102 SSC network abnormal
There is a problem in connection to Servo Amplier(XY).
(1) Shut down the machine and check the connection between the position board
and amplier.
(2) Check whether or not the servo ampliers are damaged.
4b2103 SSC network abnormal
There is a problem in connection to Servo Amplier(Head).
(1) Shut down the machine and check the connection between the position board
and amplier.
(2) Check whether or not the servo ampliers are damaged.