00197835-04_JC_PM_WF3_SX12_EN - 第38页
11 WF3 SX1/2 Clean / replace the head exhaust air filter. 5 min 2 / 2 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Mach…

11 WF3 SX1/2 Clean / replace the head exhaust air filter. 5 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T31
Wear Part:
W21
Consumables:
C19
www.asm-smt.com
1 Loosen the screw. 2 Take out the filter. 3 Blast the dirt out.
4 Check the filter for contamination. 5 If OK proceed with step 7. 6 If not OK replace the filter with a new one.

11 WF3 SX1/2 Clean / replace the head exhaust air filter. 5 min 2 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T31
Wear Part:
W21
Consumables:
C19
www.asm-smt.com
7 Return the filter. 8 Fix the screw. 9 Move the gantries to the other side.
10 Repeat all steps at the other gantry.

12 WF3 SX1/2 Clean / replace the compressed air filter - version 1. 3 min 1 / 3
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T11, T86
Wear Part:
W20
Consumables:
www.asm-smt.com
1 Open the cover. 2 Turn off the air by pushing the lever to ho-
rizontal position.
3 Push the protection cap lock (1) down and
twist the protection cap (2).
4 Push the activator or open the nut to ex-
haust the system.
5 Control the manometer shows 0 bar. 6 Unscrew the glass (1) and remove (2) it.