卧式standard头部.pdf - 第26页
Page 24 T50090901 Rev . F V/S Standard Insertion Head Assembly This Document Supports Assembly 50090901 Rev. D The following message is displayed. 7. Click on Yes . This zeros all axes. The following screen is displayed …

Page 23
V/S Standard Insertion Head Assembly T50090901 Rev. F
This Document Supports Assembly 50090901 Rev. D
Procedures and Adjustments
Insertion Head Span Axis Adjustment
Purpose:
This procedure ensures that the insertion head span axis is correctly set.
Special Tools:
Set up Tool (43806307 - Large Lead Tooling)
(43806311 - Standard, 5mm and 5.5mm Tooling)
Adjustment Procedure:
1. Push the STOP push button.
2. Palm the machine down as detailed in the Operation Manual.
3. Check that there are no leads or other debris between the flanges and
the stop collar, clean if necessary.
4. Activate the IM Diagnostics as follows. Refer to the IM-UPS and IM
Diagnostics documentation for specific details relating to the operation
of the machine terminal.
Select the IM Diagnostics icon.
WARNING
When the machine is in the IM Diagnostics function power is provided to
the machine. Exercise caution when performing the following
procedures to avoid Injury to personnel and equipment.
5. Palm the machine up and push the INTLK RESET push button.
6. After the IM Diagnostics has completed its initialization, select the fol-
lowing. Machine Set Up>Critical Axis Positions

Page 24
T50090901 Rev. F V/S Standard Insertion Head Assembly
This Document Supports Assembly 50090901 Rev. D
The following message is displayed.
7. Click on Yes. This zeros all axes.
The following screen is displayed
8. In the Set Up Critical Axis Positions screen, select the Head Drive
then click on the Disable button. Manually lower the insertion head
using the 5/16 allen wrench until the outside formers are down.
9. Select the Head Span then click on Enable to enable the span drive.
10. With the set up tool between the outside formers, set the rate to .001
then click on - Jog until the tool is held in position. Click on + Jog un-
til the tool drops from the outside formers. Click on - Jog once.
11. Click on the Set button in the Park at 0.400 In row.
12. Select Exit & Save to save the settings and exit from Set Up Critical
Axis Positions screen.
13. If no additional set ups are to be performed, exit out of the IM Diagnos-
tics function.
End of procedure.

Page 25
V/S Standard Insertion Head Assembly T50090901 Rev. F
This Document Supports Assembly 50090901 Rev. D
Head Drive Position Set up
Purpose:
Head drive critical axis position set up is required after drive pinion reassem-
bly and insert drive servo motor reassembly.
Special Tools:
None
Adjustment Procedure:
1. Push the STOP button.
2. Palm the machine down as detailed in the Operation Manual.
3. Remove the workboard holders, if mounted, from the X-Y tables.
4. Activate the IM Diagnostics as follows. Refer to the IM-UPS and IM
Diagnostics documentation for specific details relating to the operation
of the machine terminal.
Select the IM Diagnostics icon.
WARNING
When the machine is in the IM Diagnostics function power is provided to
the machine. Exercise caution when performing the following
procedures to avoid Injury to personnel and equipment.
5. Palm the machine up and push the INTLK RESET push button.
6. After the IM Diagnostics has completed its initialization, select the fol-
lowing. Machine Setup>Critical Axis Positions
The following message is displayed.
7. Click on Yes. This zeros all axes.