Contents 4 User Manual SIPLACE S-Feeder Test Station 5.2.3.5 Individual Measur ements Deviate Greatly 28 5.2.3.6 Multiple Measurements in Se quence Deviate Greatly 28 5.3 Checking the Test Tapes 29 5.4 Creating an Error …

100%1 / 38
Contents
User Manual SIPLACE S-Feeder Test Station 3
Table of Contents
1 Introduction 5
1.1 General 5
1.2 Scope of Delivery 5
1.3 Accessories 6
1.4 EU Declaration of Conformity 6
1.5 Use of Symbols 6
1.6 Safety Instructions 7
1.7 Installation Location 7
1.8 Correct and Incorrect Use 8
2 Hardware Description 9
2.1 Overview of Devices 9
2.2 Introduction - Location Surface 9
2.3 Test Tapes for the Different Feeder Types 10
3 Installation MTC 2 11
3.1 System requirements 11
3.2 Installing the Software 11
3.3 Initializing the USB Port for the Camera 14
3.4 Connecting the S-Feeder Checking Device 14
3.4.1 Connecting to the Power Supply 14
3.4.2 Connecting the Serial Port for Data Exchange 15
3.4.3 Connecting the Device Ground 16
3.4.4 Switching the Checking Device ON/OFF 16
3.5 Initial Software Start 16
3.6 Calibrating the Camera Position 17
3.6.1 Setting up the Calibration Standard 18
3.6.2 Removing the Calibration Standard 18
3.7 Update 18
3.8 Software uninstall 19
4 Software Description 21
4.1 Starting the Program 21
4.2 Main Window 21
4.2.1 Live Image View 23
4.3 File Menu 23
4.4 Menu Options 23
4.5 Help Menu 24
5 Operating the S-Feeder Test Station 25
5.1 Performing the Test 25
5.2 Evaluating the Test Results 25
5.2.1 Results display 25
5.2.2 Detailed Measurements View 26
5.2.3 Error Images 27
5.2.3.1 Measurements Outside the Tolerance 27
5.2.3.2 Repeat Accuracy Insufficient 27
5.2.3.3 Unable to Measure At Least 3 Points 27
5.2.3.4 Toothed Wheel Did Not Move 28
Contents
4 User Manual SIPLACE S-Feeder Test Station
5.2.3.5 Individual Measurements Deviate Greatly 28
5.2.3.6 Multiple Measurements in Sequence Deviate Greatly 28
5.3 Checking the Test Tapes 29
5.4 Creating an Error Report 29
6 Service Work Conveyor 31
6.1 Replace the ring light illumination board 31
6.1.1 Required Tools 31
6.1.2 Removal/installation of Lightning Board 32
6.1.3 Lighting adjustment 34
Introduction
General
User Manual SIPLACE S-Feeder Test Station 5
1
1 Introduction
Introduction
1.1
1.1 General
General
For optimum organization of your products, you need to ensure the smooth and reliable use of your feed-
er modules. You can achieve this by regularly checking your feeder modules, cleaning them when nec-
essary, servicing them and making sure that they are set correctly. These measures can significantly
reduce unscheduled downtime.
The
S-Feeder Test Station
consists of a testing device (
S-Feeder Checking Device
) and software sup-
port. The
S-Feeder Test Station
enables you to check the reliable process and functionality of your S
feeder modules with the help of an electronically supported sight check. This determines the current val-
ues and compares them to predefined tolerance values.
If the check finds that tolerance values have been exceeded, we recommend that you send the feeder
modules concerned for repair.
The
S-Feeder Test Station
can be used to check:
The general functionality of the feeder modules
The position of the teeth in the respective toothed wheel (pickup position)
The play of the toothed wheel in the and across the direction of feeding
The
S-Feeder Test Station
is designed for use with the following
SIPLACE
feeder modules:
1.2
1.2 Scope of Delivery
Scope of Delivery
The
S-Feeder Test Station
is delivered with the following:
▪1
S-Feeder Checking Device
, item no. 03071323-01
1 power pack, item no. 03041682-01
1 serial cable, item no. 03040362-01
1 set of testing tapes, item no. 03074708-01
1 CD with the
S-Feeder test software
, item no. 03076718-04
1 operating manual, item no. 00196590-03
Designation Item no.
2 x 8 mm S II 00141096-xx
3 x 8 mm S 00141098- xx
3 x 8 mm SL 00141088- xx
3 x 8 mm S; 0201/0402 00141099- xx
12/16 mm S 00141092- xx
24 / 32 mm S 00141093- xx
44 mm S 00141094- xx
56 mm S 00141095- xx
72 mm S 00141097- xx
88 mm S 00141070- xx
NOTICE
Operation
To use the S-Feeder Test Station, you need to have the calibration standard, item no.
03073729-01 (available as a separate option). This calibration standard is not supplied with the
feeder module as you only need one of these at each factory.enthalten