PIN 1 1858-1 FRONT PANEL ARROW KEYS X2 X4 3 X Operation 8. Press and hold D on the 2500's keyboard to lower the device into the programming block so you can check the alignment. You may also lower the beam with your…

100%1 / 448
°
PROGRAM/TEST ONLY
USE ARROW KEYS TO ALIGN DEVICE WITH
PROG. MODULE. PRESS [D] TO LOWER BEAM.
PRESS START TO CONTINUE.
FRONT PANEL ARROW KEYS
1857-1
Operation
4.
Press
and
to
center
the
chuck
over
the
device
(left-to-right).
Pressing
the
arrow
key
once
moves
the
beam
one
small
step
in
that
direction.
Figure
4-22
Aligning
Beam
to
the
Device
Align
Device
to
Module
Note:
You
can
change
beam
alignment
while
a
Task
is
running.
When
the
beam
hesitates
above
the
device,
press
STOP
and
use
the
front
panel
arrow
keys.
5.
Press
and
hold
D
on
the
2500's
keyboard
to
lower
the
beam
and
check
the
position
of
the
chuck
on
the
device.
For
a
slower
insertion,
lower
the
beam
manually
by
pushing
directly
on
the
top
of
the
beam
assembly,
on
either
side
of
the
beam's
limit
bar
(the
limit
bar
is
shown
in
Figure
1-7).
Adjust
the
left-to-right
position
as
necessary.
When
the
beam
is
centered,
press
START.
6.
The
beam
picks
up
the
device,
rotates
it
90
,
moves
it
over
the
programming
module,
and
pauses
before
inserting
the
device
in
the
block.
The
2500
displays:
7.
Press
and
to
center
the
device
over
the
programming
module
(left-to-right
when
you
stand
in
front
of
the
2500).
4-28
ProMaster
2500
User
Manual
PIN 1
1858-1
FRONT PANEL
ARROW KEYS
X2
X4
3
X
Operation
8.
Press
and
hold
D
on
the
2500's
keyboard
to
lower
the
device
into
the
programming
block
so
you
can
check
the
alignment.
You
may
also
lower
the
beam
with
your
hand
by
pushing
on
either
side
of
the
beam's
limit
bar
(see
Figure
1-7).
Pushing
on
the
beam
head
or
any
other
part
of
the
beam
might
distort
the
alignment.
Figure
4-23
Aligning
Device
to
the
Module
ProMaster
2500
User
Manual
4-29
°
PROGRAM/TEST ONLY
USE ARROW KEYS TO ALIGN BEAM WITH
DEVICE CENTER. PRESS [D] TO LOWER BEAM.
PRESS START TO CONTINUE.
1859-2
X
4
X
1
X
3
FRONT
OF 2500
Operation
Check
Front-to-back
Position
Figure
4-24
Checking
the
Front-to-Back
Alignment
(looking
from
the
perspective
of
the
input
track)
9.
After
the
device
is
centered
right-to-left,
check
its
front-to-back
position
by
looking
at
the
device
and
programming
module
from
over
the
input
track.
Adjust
Front-to-back
Position
10.
If
the
device
is
centered
over
the
programming
module
in
the
front-
to-back
axis,
press
START
to
resume
operation.
If
the
device
is
not
centered
front-to-back,
note
whether
it
is
too
close
to
the
front
or
back,
and
perform
the
following
steps
to
readjust
its
position.
To
realign
the
beam
so
that
the
device
moves
into
the
center
of
the
programming
module
on
the
front-to-back
axis,
follow
the
steps
below.
1.
Exit
the
Task
or
Kit,
restart
it,
and
prepare
to
recheck
the
alignment.
2.
The
beam
will
pause
above
the
device
and
the
2500
displays:
3.
If
the
device
was
too
close
to
the
front
of
the
programming
module,
press
once
or
twice
so
that
the
chuck
picks
up
the
device
a
little
to
the
right
of
its
original
position
(see
Figure
4-25).
This
is
done
to
compensate
for
the
fact
that
the
beam
rotates
the
device
90
before
inserting
it
in
the
programming
module's
block.
If
the
device
was
too
close
to
the
back
of
the
programming
module,
press
once
or
twice
so
that
the
chuck
picks
up
the
device
a
little
to
the
left
of
its
original
position
(see
Figure
4-26).
4-30
ProMaster
2500
User
Manual