2500_Users_Manual- - 第179页
ENTER LABEL C ALIBRATION VALUE ( X ): ENTER LABEL A DJUST VALUE ( X ): 1944-1 NORMAL HIGHER VALUE Preventive Maintenance Adjusting Position of Print on Label (Dot Matrix Printer) The left-to-right position of characters …

Preventive
Maintenance
Corrective
Adjustments
Changing
Dot
Matrix
Printer
Ribbon
Cassette
Refer
to
the
procedure
on
page
5-57.
Changing
Thermal
Printer
Ribbon
Refer
to
the
procedure
on
page
5-59.
Adjusting
Dot
Matrix
Print
Head
Gap
The
print
head
gap
is
set
at
the
factory
and
will
not
usually
need
to
be
changed.
If
there
are
substantial
changes
in
the
thickness
of
the
label
or
label
backing,
however,
you
may
need
to
make
an
adjustment.
If
the
gap
between
the
platen
and
the
print
head
is
too
wide,
it
may
result
in
slanted
or
fuzzy
printing.
If
the
gap
is
too
narrow,
the
print
ribbon
may
rub
against
the
labels,
smudging
them
and
making
the
background
gray.
CAUTION:
Dangerous
high
voltages
are
present.
Do
not
perform
this
procedure
while
power
is
on
to
the
2500.
This
procedure
should
be
performed
only
by
a
qualified
service
technician.
To
adjust
the
print
head
height,
follow
these
steps:
1.
Turn
off
and
unplug
the
2500.
2.
Remove
the
ribbon
cartridge
and
labels.
3.
Locate
the
two
corner
screws
on
the
main
plate
that
hold
the
plate
in
position.
Loosen
these
screws
so
the
plate
is
free.
4.
Lift
the
main
plate
so
you
can
see
inside
the
2500's
base.
5.
Locate
the
four
hex
screws
on
the
back
side
of
the
print
head
that
hold
it
in
position.
Loosen
the
screws,
but
do
not
remove
them.
6.
When
the
print
head
is
free
to
move,
move
it
as
far
to
the
right
as
possible,
then
adjust
the
gap
between
the
print
head
and
the
underside
of
the
platen
to
approximately
0.018
inches.
7.
Hold
the
print
head
in
this
position
and
tighten
the
four
hex
screws.
5-24
ProMaster
2500
User
Manual

ENTER LABEL CALIBRATION VALUE (X):
ENTER LABEL ADJUST VALUE (X):
1944-1
NORMAL
HIGHER VALUE
Preventive
Maintenance
Adjusting
Position
of
Print
on
Label
(Dot
Matrix
Printer)
The
left-to-right
position
of
characters
on
the
label
is
determined
by
label
calibration.
Figure
5-6
Adjusting
Label
Calibration
You
can
change
the
label
calibration
setting
during
a
Task
run
by
pressing
STOP
and
then
LOWER
CASE
+
C.
The
2500
displays:
The
X
represents
the
current
setting.
The
default
setting
places
the
first
column
of
print
within
0.040
inches
of
the
leading
edge
of
the
label.
Increasing
the
value
one
unit
moves
the
print
location
approximately
0.005
inches
to
the
right;
decreasing
the
value
moves
it
0.005
inches
to
the
left.
Enter
a
number
from
0
to
255,
and
press
ENTER.
If
you
change
label
calibration,
press
CAL
to
calibrate
the
label
(see
page
4-19).
Adjusting
Position
of
Label
on
Device
(Dot
Matrix
Printer)
The
position
of
the
label
on
the
device
is
determined
by
the
label
placement
value.
This
is
set
in
the
system
defaults
to
“Auto
center,”
which
instructs
the
2500
to
place
the
label
on
the
true
center
of
the
device.
You
can
change
label
placement
using
a
local
mode
command
described
in
Appendix
F.
You
can
use
the
Label
Adjust
parameter
to
flne-tune
label
placement
and
thereby
adjust
its
centering
while
a
Task
is
running.
Press
STOP
and
then
LOWER
CASE
+
A.
The
2500
displays:
Enter
a
number
from
0
to
255;
each
unit
moves
the
label
0.01
inch
closer
to
the
trailing
edge.
Press
ENTER
to
accept
the
selection.
Note:
This
works
only
w
加避
"Aut。
center”
is
selected
in
the
2500
Setup/Labeler
menu.
ProMaster
2500
User
Manual
5-25

↑ ↓
1656-2
INCREASE DECREASE
2177-1
NORMAL
HIGHER VALUE
Preventive
Maintenance
Adjusting
Press
Bearings
Make
sure
the
dot
matrix
printer's
application
plate
is
aligned
correctly
by
holding
a
device
in
your
fingers
and
sliding
it
across
the
application
plate,
over
the
press
bearings,
and
onto
the
bearing
plate
(see
Figure
2-8).
The
device
should
move
smoothly
across
the
press
bearings.
If
device
travel
is
not
smooth,
use
a
7/64-inch
hex
wrench
to
loosen
(to
raise)
or
tighten
(to
lower)
the
screw
on
the
left
side
of
the
plate
(near
the
bearings)
until
a
smooth
transition
occurs
(see
Figure
2-8).
Adjusting
Print
Position
on
the
Label
(Thermal
Printer)
Two
parameters
control
the
position
of
text
and
graphics
on
the
label.
By
changing
the
value
of
each
parameter,
the
location
of
the
text
or
graphics
printed
on
the
label
can
be
adjusted.
•
The
print
shift
value
affects
the
vertical
position
of
the
printed
image,
moving
the
position
of
characters
or
graphics
from
the
top
to
bottom
of
the
label
(Y
axis).
See
Figure
5-7.
•
The
label
calibration
value
affects
the
horizontal
position
of
the
printed
image
on
the
label,
moving
the
position
of
the
text
or
graphics
from
left
to
right
(X
axis).
See
Figure
5-8.
Figure
5-7
Print
Shift
(affects
vertical
position)
Figure
5-8
Label
Calibration
(affects
horizontal
position)
Print
Shift
Change
this
value
using
the
STOP
command
described
in
the
following
procedure.
1.
Press
STOP
to
pause
the
2500
while
a
Task
is
running.
2.
Press
LOWER
CASE
+
P.
The
display
on
the
2500
prompts
you
to
enter
a
new
value.
3.
Press
or
to
enter
a
new
print
shift
value
between
0
and
16.
Entering
a
larger
numeric
value
moves
the
printed
character
higher
on
the
label.
4.
Press
START
to
continue
running
the
Task.
5-26
ProMaster
2500
User
Manual