2500_Users_Manual- - 第389页
E Computer Remote Control The Computer Remote Control (CRC) commands are used by TaskLink to control the operation of the 2500. This information is included in the manual to allow you to write a remote computer software …

Translation
Formats
D-58
ProMaster
2500
User
Manual

E
Computer
Remote
Control
The
Computer
Remote
Control
(CRC)
commands
are
used
by
TaskLink
to
control
the
operation
of
the
2500.
This
information
is
included
in
the
manual
to
allow
you
to
write
a
remote
computer
software
program
(referred
to
as
a
driver)
to
control
the
operation
of
the
ProMaster
2500.
The
CRC
driver
issues
commands
in
the
format
required
by
the
2500
and
sends
these
commands
to
the
2500
to
execute.
The
2500
performs
the
handling
and
programming
operation
and
then
returns
a
response
character
that
indicates
status
or
returns
requested
data.
The
driver
interprets
this
response,
determines
on
the
next
action,
and
generates
messages
and
operator
prompts.
The
complete
set
of
ProMaster
2500
computer
remote
control
commands
are
divided
in
this
chapter
into
three
groups
of
related
commands.
Each
has
a
slightly
different
set
of
requirements
described
in
the
appropriate
section.
These
groups
are:
•
Handler
Computer
Remote
Control
Commands
—
Set
of
commands
controlling
the
handling
of
devices
from
the
input
tube,
into
the
programming
module,
through
label
application,
and
releasing
the
device
into
the
output
tube.
•
Labeler
Hex
Format
Commands
—
Control
the
specific
characteristics
of
text
on
the
label.
•
Programming
Electronics
Remote
Control
Commands
—
Set
of
commands
to
control
the
programming
of
devices
in
the
programming
module.
ProMaster
2500
User
Manual
E-l

Computer
Remote
Control
Handler
Computer
Remote
Control
This
section
lists
commands
that
specifically
affect
the
device
handling
functions
of
the
2500.
It
includes
the
following
information:
•
Handler
Remote
Command
Set
—
Lists
the
available
handler
CRC
commands.
A
command
summary,
which
lists
commands,
descriptions,
and
the
2500's
response,
precedes
the
complete
list.
•
Handler
Remote
Error
Codes
—
Lists
the
handler
error
codes
that
may
be
returned
while
the
2500
is
being
operated
in
computer
remote
mode.
System
Setup
The
2500
handler
and
labeler
controllers
receive
CRC
commands
and
send
responses
to
the
host
computer
through
the
RS-
232c
port
labeled
“Remote
RS232”
on
the
back
of
the
2500.
This
is
the
only
port
that
will
respond
to
the
handler
or
labeler
CRC
commands
listed
in
this
section.
To
ensure
correct
operation
of
the
Remote
port
with
the
host
computer,
set
the
parameters
for
the
Remote
port
according
to
the
host
computer
requirements.
Note:
The
default
baud
rate
for
computer
remote
mode
is
9600.
E-2
ProMaster
2500
User
Manual