00196478-08_MM_SX12DX12_en - 第56页
Major Maintenance Maintenance Tasks for Optical Systems 5.4.1 Tools, Consumables, Spare and Wear Parts 56 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 5.4 5 . 4 M a in t e n a n c e T a s k s f o r O p t ic a l S y s t e m…

Major Maintenance
5.3.2 Performing Maintenance Tasks Maintenance Tasks for the Component Feed Device
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 55
5.3.2.6
5.3.2.6 Greasing the Centering Strip on the Component Trolley/Feeder Table for X Feeders
Greasing the Centering Strip on the Component Trolley/Feeder Table for X Feeders
Centering guide rail at the component trolley (SX4 as ex
-
ample)
Centering guide rail at the manual table (DX4 as exam
-
ple)
► Apply "Surface Shield oil spray" [00328575-xx] to a
lint-free cloth and then thinly oil the centering strip (1).
Pay particular attention to the centering holes.
Alternatively you can also use a SIPLACE cleaning
tissue.
► Then wipe the centering strip with a lint-free cloth.
► Repeat these steps for all component trolleys and
manual tables.

Major Maintenance
Maintenance Tasks for Optical Systems 5.4.1 Tools, Consumables, Spare and Wear Parts
56 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
5.4
5.4 Maintenance Tasks for Optical Systems
Maintenance Tasks for Optical Systems
5.4.1
5.4.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
▪ Microfiber cloth for cleaning optical assemblies
▪ ESD wristband [00320279-xx]
▪ Cotton gloves [00359087-xx]
▪ Vacuum cleaner
5.4.2
5.4.2 Preparatory Steps
Preparatory Steps
► Undock the component trolleys and move them out of the machine.
► Switch off the machine and secure it to prevent unauthorized reactivation. Observe the instructions
in section "1.2 Preparatory Work..." [ ➙ 12].
5.4.3
5.4.3 Performing Maintenance Tasks
Performing Maintenance Tasks
5.4.3.1
5.4.3.1 Cleaning the IC and FC Cameras
Cleaning the IC and FC Cameras
CAUTION
Risk of cutting yourself on the glass disk!
► There is a risk of cutting your fingers along the edges of the glass disk.
► Wear cotton gloves as protection and avoid touching the edges. The cotton gloves are also
required for effective cleaning (to avoid fingerprints!).
CAUTION
Electrical components
Make sure that the electrical components are not live!
NOTICE
IC, FC camera
This cleaning procedure is the same for IC (type 33) and FC cameras (type 25).
► Carefully lift the upper section (1) of the IC camera up
and off.
CAUTION!
Do not get the upper sections mixed up.
The upper sections of the different cameras are coordi-
nated with the specific lower sections and may not be
mixed up.

Major Maintenance
5.4.3 Performing Maintenance Tasks Maintenance Tasks for Optical Systems
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 57
► Repeat these steps for all IC and FC cameras.
5.4.3.2
5.4.3.2 Cleaning the PCB Barcode Scanner
Cleaning the PCB Barcode Scanner
CAUTION!
There is a risk of cutting yourself on the edges of the
glass disk!
► Clean the slanted glass disk (1) with a microfiber
cloth.
CAUTION!
Do not use any chemical cleaning agents!
► Remove any components which have collected in the
duct (2) underneath the glass disk.
► Refit the upper part.
CAUTION!
Make sure that you do not damage the glass disk.
Make sure that the upper part of the camera slides
smoothly into the (1) guidance.
Make sure that the upper part of the camera is evenly
seated on the lower section and that it cannot move. If
necessary, gently press against the metal cover of the
upper part.
Make sure that the upper part does not protrude at the
upper edge of the conveyor.
► Clean the lens (1) of the PCB barcode scanner with a
microfiber cloth.