Major Maintenance Maintenance Tasks for the Convey or 5.6.1 Tools, Consumables, Spa re and Wear Parts 66 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 5.6 5 . 6 M a in t e n a n c e T a s k s f o r t h e C o n v e y o r Mai…

Major Maintenance
5.5.4 Final Work Maintenance Work on the Gantry
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 65
5.5.3.8
5.5.3.8 Replacing the Loose Bearing Lubrication System Y Axis
Replacing the Loose Bearing Lubrication System Y Axis
See also
5.5.3.6 Cleaning the Y Axis Scale [ ➙ 62]
4.3.2.3 Cleaning the Y Axis Loose Bearing and Contact Surface [ ➙ 31]
5.5.3.4 Cleaning the Linear Guides of the Y Axis [ ➙ 62]
5.5.4
5.5.4 Final Work
Final Work
► For SW703.02 and higher only: switch the placement machine on and reset the maintenance cycle
counter for the relevant assemblies.
Overview of lubrication systems on the gantry
The lubrication systems are located on the loose bearing
side of the gantry! Each gantry has two lubrication sys-
tems.
► Unscrew the two lubrication systems (1) and (2) from
the gantry. One lubrication system is on the side fac-
ing you and the other one is on the side of the gantry
facing away from you.
► Use a dry cloth to clean the Y axis rollers, linear
guides and scales.
► Move the gantry twice over the entire length. Now
clean the Y axis rollers and linear guides again.
► Screw the protective caps off the new lubrication sys-
tems.
CAUTION!
Take care not to distort the felt insert.
► Screw the new lubrication systems hand-tight into
place.
► Repeat the procedure on the second gantry, if neces-
sary.

Major Maintenance
Maintenance Tasks for the Conveyor 5.6.1 Tools, Consumables, Spare and Wear Parts
66 Maintenance Manual SIPLACE SX1/SX2/DX1/DX2
5.6
5.6 Maintenance Tasks for the Conveyor
Maintenance Tasks for the Conveyor
5.6.1
5.6.1 Tools, Consumables, Spare and Wear Parts
Tools, Consumables, Spare and Wear Parts
▪ ESD wristband [00320279-xx]
▪ OIL Interflon Fin Super (teflon oil) [03017760-xx]
▪ Lint-free cleaning tissues [03082092-xx]
▪ Ethanol
Isopropanol – IPA can be used as an alternative.
▪ SIPLACE cleaning tissue [00315253-xx]
▪ Protective latex gloves [00372972-xx]
▪ Cotton gloves [00359087-xx]
5.6.2
5.6.2 Preparatory Steps
Preparatory Steps
Caution Conveyor - No PCB Must Be in the Conveyor
Note Co nveyor - Re commendation: Ad justing Sides via S oftware for Acces sibility
► Move the component trolley out of the machine.
See also
1.2 Preparatory Work... [ ➙ 12]
CAUTION
No board
There must be no PCBs in the machine during the following tasks.
NOTICE
Accessibility
We recommend using the following procedure for better access:
► Use the station software to adjust the conveyor sides in such a way that you can easily
reach all conveyor belts as well as the whole area below the sides.

Major Maintenance
5.6.3 Performing Maintenance Tasks Maintenance Tasks for the Conveyor
Maintenance Manual SIPLACE SX1/SX2/DX1/DX2 67
5.6.3
5.6.3 Performing Maintenance Tasks
Performing Maintenance Tasks
5.6.3.1
5.6.3.1 Cleaning and Preserving the Conveyor
Cleaning and Preserving the Conveyor
Preservi ng the Conveyor - Preparator y Tasks: Moving Sides Etc.
Moving the Conveyor Sides
► Move all conveyor sides to one side of the conveyor.
DC: Use the station software to set the dual conveyor to single conveyor mode (right).
SC: Use the station software to move the moveable side to one side of the conveyor.
► First perform the following cleaning and preserving steps only to the side of the conveyor which is
now free.
Cleaning and Preserving the Hexagonal Shafts
CAUTION
Observe the exact order
► Observe the following steps in exactly the order shown.
NOTICE
Keeping the clamping surfaces clean (dual conveyor only)
► During work, keep the clamping surface free of any dirt or oil. This makes subsequent
cleaning much easier.
Overview of the hexagonal shafts in the conveyor
► Apply Teflon oil to a lint-free cloth and clean the hex-
agonal shafts (1) in the conveyor.
Alternatively you can also use a SIPLACE cleaning
tissue.
CAUTION!
Never apply the Teflon oil to the cloth inside the machine.
Where possible, go away from the machine.
► Repeat the procedure for all hexagonal shafts in the
conveyor.