NR_Mechanischer_Stopper - 第165页

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D 3 / HF- / X-Series Edition 06/2007 165 O Before doing so, remove the cab le tie with which the black cable is attached to the air distr ib…

100%1 / 238
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
164
O Clean the conveyor tub in the area of the guide strip with a lint-free cloth moistened with ethyl
alcohol.
Fig. 141
O Relocate any cables that may run there.
13
Caution: Before the stopper is mounted in the machine, it should be adjusted with the guide strip
and the shims. Care should be taken to ensure that the stopper is not too loose or too tight. The
graduation of the shims is 0.1mm.
(See also Fig. 209, page - 232.) 13
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
165
O Before doing so, remove the cable tie with which the black cable is attached to the air distrib-
utor.
O Push the guide strip into the conveyor from outside.
Insert the stopper units carefully between the two side sections into the guide slot of the guide
strip.
Fig. 142
13
Stopper PA1
Conveyor track 2
Stopper PA1
Conveyor track 1
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
166
O First attach the trailing cable distance block (flat distance block) of conveyor track 2 on the
mounting tub. The distance block should be attached in the center under conveyor side 2 di-
rectly next to the main air distributor of the conveyor.
For HS-60 and D4 (mounting tub 587 mm) with dual and single conveyor, the following distances
must be observed:
Fig. 143 Positions of the distance blocks (HS-60, D4)
For a dual conveyor, stick an additional "Distance block for energy chain, complete"
[03043432-xx] in the middle between the two energy chain distance blocks for better movement
of the trailing cable.
Conveyor track 2 Conveyor track 1
Distance block for energy chain
Left
conveyor side
Right
conveyor side
340 mm 240 mm
440 mm
140 mm
Transport direction
Left side of
mounting tub
Right side of
mounting tub
587 mm