NR_Mechanischer_Stopper - 第234页
Assembly Instructions PCB Stopper Sin gle Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series Edition 06/2007 234

Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
233
If the stopper cannot be moved in or out within a given time, you can adjust the speed of the stop-
per with the throttles. 19
Note:
Check whether there are any components in the guide of the stopper.
Remove them if necessary. 19
Fig. 210
19
All the sensors and functions of the stopper can be activated and monitored generally via the
SITEST. 19
19
Connection 4 Connection 2
Black = Conec-
tion of rotatng
cylinder
Insert stopper
with adjustable
throttle
Blue = Connec-
tion of rotating
cylinder
Withdraw stop-
per with adjust-
able throttle
Compressed air
supply
Solenoid valve
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
234
Assembly Instructions PCB Stopper Single Conveyor SIPLACE S-27HM / HS-60 / D4 / D3 / HF- / X-Series
Edition 06/2007
235
20 Maintenance
The stop rail of the component stopper should be vacuumed once per shift.
The guide strip should also be cleaned once a week.
On some conveyors the clamping strip of the width adjustment is very close to the stopper. So be
careful not to damage this clamping strip when cleaning the guide strip. 20
20