2. Connecting the Air Objective Connect the air hose to the machine and adjust the regulator so that sufficient air pressure is supplied to the machine. Procedure 1. Connect the drain hoses to the filter regulator. Note:…

100%1 / 110
Notes:
Part 4 Chapter 1 Leveling the Machine
Edition 1.0 4-1-2 NP-134E/134ME Mechanical
2. Connecting the Air
Objective
Connect the air hose to the machine and adjust the regulator so that sufficient air
pressure is supplied to the machine.
Procedure
1. Connect the drain hoses to the filter regulator.
Note: The drain hoses should be ø 4 ~ 5 (inside) and ø 10 (outside).
2. Connect the hose to the air inlet.
3. Pull up on the regulator knob to release the lock.
4. Adjust the valve handle until the pressure level indicated at the regulator shows
0.5 MPa (5 kgf/cm
2
).
5. Push the regulator knob down to lock it.
Note: The hose is not supplied by Fuji.
NP1MS051
400SH ( for 1/2" hose) socket
Drain hoses
Hose
400PM plug
Handle
Part 4 Chapter 2 Connecting the Air
Edition 1.0 4-2-1 NP-134E/134ME Mechanical
Notes:
Part 4 Chapter 2 Connecting the Air
Edition 1.0 4-2-2 NP-134E/134ME Mechanical