SiplaceX4_en - 第131页

1 - 61 S tudent Guide SIPLACE X Edition 09/2005 3 Communication and Control 61 Allocation of subsy stems to the hardware component s e.g. Siplace X P A1 PPW --> Nozzle changer (NC) Subsystem Hardware component s Notes…

100%1 / 670
1 - 60
Student Guide SIPLACE X
3 Communication and Control Edition 09/2005
60
3.5.3.2 Overview Initialization of the One Wire Bus
(1) CAN BUS command for initialization
(2) CAN BUS command sent.
(3) Subsystems give a message via the public bytes
1f --> Coupler 12 --> I/O component with EEPROM 14 --> 1k EEPROM
20 --> 4 channel A/D 23 --> 4k EEPROM 28 --> Temperature
29 --> 8 x I/O component
(4) Answer initialization successful.
1
2
4
3
1 - 61
Student Guide SIPLACE X
Edition 09/2005 3 Communication and Control
61
Allocation of subsystems to the hardware components
e.g. Siplace X PA1
PPW --> Nozzle changer (NC)
Subsystem Hardware components Notes
PPW, 1, Coupler, 00 RS232 Interface on the I/O
module
Temperatur, 20, Coupler, 00
RS232 Interface on the I/O
module
PPW, 4, Coupler, 00 RS232 Interface on the I/O
module
Mainpath, 0, IO_2C, 01
Mainpath, 0, E2_512B, 01
RS232 Interface on the I/O
module
RS232 Interface board will be integrated
in the I/O module later.
Temperatur, 20, E2_32B, 01
Temperatur, 20, E2_512B, 61
Temperatur, 20, Temperatur, 10
Temperatur, 20, Temperatur, 11
Temperatur, 1, IO_2C,01
Temperature sensors
Gantry 1
The two temperature sensors form a unit
and can only be replaced as a set. The
part for the gantry recognition can not
change.
Temperatur, 20, E2_32B, 81
Temperatur, 20, E2_512B, e1
Temperatur, 20, Temperatur, 90
Temperatur, 20, Temperatur, 91
Temperatur, 20, IO_2C,81
Temperature sensors
Gantry 4
The two temperature sensors form a unit
and can only be replaced as a set. The
part for the gantry recognition can not
change.
PPW, 4, AD, 03
PPW, 4, AD, 01
PPW, 4, AD, 81
1 Wire Hub NC on location 4 Shows, that the 1 Wire Hub is connected .
PPW, 4, E2_32B, 01
PPW, 4, IO_8C, 01
PPW, 4, AD, 01
Control board NC Gantry 4,
only C&P20 NC
Control board of NC row 1
(only C&P 20 NC).
PPW, 4, E2_32B, 81
PPW, 4, IO_8C, 81
PPW, 4, AD, 97
Control board NC Gantry 4,
only C&P20 NC
Control board of NC row 2
(only C&P 20 NC).
PPW, 1, AD, 01
PPW, 1, AD, 03
PPW, 1, AD, 81
1 Wire Hub NC on location1 Shows, that the 1 Wire Hub is connected.
PPW, 1, E2_32B, 01
PPW, 1, IO_8C, 01
PPW,1 AD, 15
Control board NC Gantry 1,
only C&P20 NC
Control board of NC row 1
(only C&P 20 NC).
PPW, 1, E2_32B, 81
PPW, 1, IO_8C, 81
PPW, 1, AD, 97
Control board NC Gantry 1,
only C&P20 NC
Control board of NC row 2
(only C&P 20 NC).
1 - 62
Student Guide SIPLACE X
3 Communication and Control Edition 09/2005
62
Notes: