SiplaceX4_en - 第181页

1 - 35 S tudent Guide SIPLACE X Edition 09/2005 4 Servic es to the machine 35 4.3.3.2 Compressed air distribution in Main Pneumatic Unit The picture below illustrates th e compressed air distribution: – gantry1-2: air su…

100%1 / 670
1 - 34
Student Guide SIPLACE X
4 Services to the machine Edition 09/2005
34
4.3.3.1 Manometer Arrangement
Fig. 4.3 - 3 main pneumatic unit: manometer arrangement
Legend:
1. Manometer for input pressure 5-10 bar
2. Manometer for bulk case and nozzle changer 2.5 +-0.5 bar
3. Manometer for gantries 5.0 +0.1 bar (vacuum for C&P head and Twin head)
4. Mmanometer for machine units 5.0 +0.1 bar (tape cutter, transport, docking unit (co-table)
5. Pressure sensor proportional valve (placement heads)
6. Filter
7. Regulator for machine units (Tape cutter, Transport, Docking unit, COT)
1
4
6
5
2
3
7
1 - 35
Student Guide SIPLACE X
Edition 09/2005 4 Services to the machine
35
4.3.3.2 Compressed air distribution in Main Pneumatic Unit
The picture below illustrates the compressed air distribution:
gantry1-2: air supply through 2 hoses (gantry 3/4 not used)
tape cutter 1-4: air supply through 4 hoses
docking unit (co-table) 1-4: air supply through 4 hoses
bulk case 1-4: air supply through 4 hoses
nozzle changer 1-2: air supply through 2 hoses
transport: air supply with 1 hose
Fig. 4.3 - 4 pneumatic distribution block in main pneumatic unit
3
4
2
1
gantry 1 - 4
4
3
2
1
bulkcase
1-4
2,5 bar
adjustable
nozzle
changer
1 2
34
nozzle changer
2,5 ba r
adjustable
docking unit
(co-table)
5 bar
adjustable
conveyor
5 bar
adjustable
5 bar
adjustable
1 2 3 4
compressed air distribution block
tape cutter
1 - 4
4 3
21
1 - 36
Student Guide SIPLACE X
4 Services to the machine Edition 09/2005
36
4
Fig. 4.3 - 5 overview pneumatic unit (distribution block)
nd:
ut of valves gantries
upply docking units
ulk case Feeder&nozzle changer
upply tape cutter/Transport
tart and control Y-drive cooling
ometers:
put pressure
pply of bulk case Feeder/nozzle
ger 2.5 bar
ct
. regulated supply of gantries
pply ‘machine’ 5 bar include
ing units tape cutters/PCB
ey.
main air input 5-10 bar
X60
Y-axis cooling motor
control device
Y-axis cooling motor
pressure
sensor
S
h
u
t
-
o
f
f
v
a
l
v
e
prop.
valve
5 bar
safety valve
filter
regulator
5 bar
1
3
2
4
regulator
2.5 bar
main valve
power and motor control signal
power and control signal
power and control signal
Y axis
motor
power and
control signal
5 bar
5
b
a
r
5 -10 bar
4.8 bar
(4)
(3)
(2)
(1)
connector
board
4.8 +0.1 bar
compressed air
distribution block
5 bar
K2
K1
X58
X59
2
.
5
b
a
r
(5)