1 - 24 S tudent Guide SIPLACE X 8 Collect&Place-Head 20 Edition 09/2005 24 8.2.6 V acuum Check Procedure The vacuum check serves for control of soiled and dam aged nozzles as well as for the ch eck of the nozzle type…

100%1 / 670
1 - 23
Student Guide SIPLACE X
Edition 09/2005 8 Collect&Place-Head 20
23
8.2.5 DP Axis Reference Run
The DP axis rotates the nozzle into the correct pickup angle and placement angle.
After component recognition has been performed, the DP axis turns the components into the cor-
rect placement angles and the determined correction angle from the vision system.
Fig. 8.2 - 5 DP axis reference run
The machine start procedure: After the DP master firmware is loaded the DP drives are initial-
ized.
After the reference runs for the Star axis and Z-axis have been performed, the segments rotate
into the 0° position.
The DP axes can also be referenced independently of the star and Z axes.
By determination of the largest amplitude of the Hall sensor becomes the 0° position of the noz-
zle in the factory (mechanically adjusted) and can't be changed.
The C&P head reference run has been successfully completed!
The gantry reference run will now be performed. For details, please refer to the chapter Gantry.
1
2
3
4
5
6
7
8
9
10
12
11
13
14
15
16
17
18
19
20
Segment 1
Segment 11
S
t
a
r
p
o
s
i
t
i
o
n
CO- Camera
1 - 24
Student Guide SIPLACE X
8 Collect&Place-Head 20 Edition 09/2005
24
8.2.6 Vacuum Check Procedure
The vacuum check serves for control of soiled and damaged nozzles as well as for the check of
the nozzle types.
Fig. 8.2 - 6 Vacuum check procedure
The gantry axes move the C&P head into the reject position to clean the nozzles before mea-
surement.
The Star axes move in an anticlockwise direction and all cleaning functions are performed at
the same time, within one head cycle. (see Fig. 8.2 - 6).
(1) The DP drives rotate each segment into the 0° position.
(2) The digital pressure control valve now activates the air kiss for the reject position. The com-
ponents still on the nozzle will be rejected.
(3) The vacuum reference values (open/closed) are measured at the pickup/placement position
during the height reference run.
PLEASE NOTE:
In SIPLACE X machines, components are rejected in the pickup/placement position.
1
2
3
4
5
6
7
8
9
10
12
11
13
14
15
16
17
18
19
20
Segment 1
Segment 11
S
t
ar
p
o
s
i
t
i
o
n
CO- Camera
2
3
,
1
1
20
to
1 - 25
Student Guide SIPLACE X
Edition 09/2005 8 Collect&Place-Head 20
25
8.2.7 Determining the Vacuum and Threshold Values
Fig. 8.2 - 7 Measuring and calculating the vacuum values for a reference run
1. The vacuum is measured twice at the reference point: once with closed and once with open
state, at the top of the nozzle.
2. The value with closed valve depends not anymore on the ambient pressure it is controlled by
the pressure control valve. A influence to the vacuum values are the nozzle fit on the segment
and the quality f the nottle top and the surface of transport rail at height measurement position.
3. The value by open valve depends on the nozzle size and condition. The smaller the nozzle,
the greater the open valve value will be. A contaminated or blocked nozzle will also give a
higher valve.
4. The difference between the open and closed nozzles has been preset by the line computer as
an ideal case minimum value. This value is different for all nozzle types e.g. 120 mbar for 1004,
1014 nozzles. If these values are not achieved, the error message "vacuum difference open-
closed is too low" will appear.
5. The threshold for component acceptance is also set now. Assumed are following values of 660
mbar by open nozzle and 852 mbar by closed nozzle on the transport rail.
The calculation is as follows:
Vacuum distance = 852(closed) - 660(open)= 192 mbar (larger than the min. distance on
nozzle type parameter set.
Threshold (192 mbar x 0.2)+ 660 (open value) = 698,4 mbar