1 - 21 S tudent Guide SIPLACE X Edition 09/2005 2 Overview 21 Each S-table has fif teen slots for 8 mm SIPLACE feeders. This amounts to a tot al capacity of 180 tracks for 8mm tapes, if 4 componen t tables are used. Each…

1 - 20
Student Guide SIPLACE X
2 Overview Edition 09/2005
20
2.2.6 Component changeover tables
A new feeder generation has been developed for the Siplace X. These new feeders also require
a new component table. The new table has no electronic assemblies. The conventional compo-
nent table uses the communication unit for feeder supply and control. The power supply to the
feeders is now non-contacting, run via an inductive interface at the docking unit, directly to the
feeders. The control and communication between the feeder control unit (FCU) and the feeders
is conducted via two optoelectronic channels (fiber optics). The FCU is connected to the machine
control unit via the machine CAN Bus. Both S-tables and X-tables can be used with the machine.
Restriction: If the machine has C&P20 heads, only X-tables may be used.
2.2.6.1 Docking and Undocking
The changeover table (COT) is automatically docked and undocked to/from the machine via 2
pneumatic cylinders. To dock the COT, move the table to the docking unit, close the cover and
press button 5. To undock the COT, open the cover and press button 5.
.
Fig. 2.2 - 8 Shows the buttons for docking and undocking the COTs
(1-4) Component table location 1 - location 4
(T) Direction of transport
(5) Button to dock and undock component changeover tables
5
5
5
5

1 - 21
Student Guide SIPLACE X
Edition 09/2005 2 Overview
21
Each S-table has fifteen slots for 8 mm SIPLACE feeders.
This amounts to a total capacity of 180 tracks for 8mm tapes, if 4 component tables are used.
Each X-table has 40 slots for 8mm X-feeders, amounting to a total capacity of 160 individual
tracks, if 4 component tables are used
2.2.6.2 Adjusting the Changeover Table Height
The COT can be manually adjusted for the following PCB transportation heights.
Adjustment of S-tables and X-tables is identical.
– 830 mm ± 15 mm standard height
– 900 mm ± 15 mm SMEMA height
– 930 mm ± 15 mm SMEMA height
– 950 mm ± 15 mm SMEMA height
Fig. 2.2 - 9 COT for X-feeder COT for S-feeder
(1) Holes drilled for the various PCB transport heights. adjustment is via insertion of a split pin.
(2) Contact surface (block) for upper part of table
(3) Component table
(4) Reed switch to close the safety circuit to the docking unit
1
Component table for X feeder
Component table for S feeder

1 - 22
Student Guide SIPLACE X
2 Overview Edition 09/2005
22
2.2.6.3 Overview of X-Feeder
The new generation of X-feeders enables the operator to install feeders on the machines for each
different component type (single track feeder). This ensures optimum exploitation of the machine
locations and optimum preparation of setups for the individual placement procedures.
If errors should occur during production, the X-feeder can be "logged out" and replaced by another
feeder, which is then logged into the system.
A splice sensor can be optimally integrated directly into the feeder.
Fig. 2.2 - 10 Example of 8mm X-feeder
Fig. 2.2 - 11 Control panel for X-feeder
(1) "Forwards" button
Press briefly to move the tape by the set cycle time.
Press for longer to move the tape forwards. Make sure the cover sheet is not clamped in.
(2) "Backwards" button
Press briefly and release to move the tape backwards by the set cycle time.
Press for longer to move the tape backwards. (Only perform these functions when the cover
sheet is not clamped in)
(3) "Foil" button: press to start the strip removal motor. This runs until the sheet has been
stretched tight and the motor toggle switch turns off or until the timer has counted 30 seconds.
(4) Briefly press the "SET" button to switch over to the next menu in the main operator level
Press for longer to request component verification.
Pickup position
Motors for delivery of components
Mechanical and electrical unlock release
Display, control panel and status display
Motor for cover sheet
SIEMENS
Spur 01 4mm
SIEMENS
Spur 01 4mm
Direction of transport
Cycle time
Display showing track on location
1
2
3
4